The current proposal will help to expand the Institute for System Biology's (ISB) Proteomics facility by providing capital to purchase a Fourier transform-ion cyclotron-resonance mass spectrometer (FTMS). Currently, the Proteomics facility focus is on large scale application of a novel approach to the systematic identification and accurate quantitation of the proteins present in cells and tissues and therefore detection of dynamic changes in global protein expression profiles that are characteristic for biological processes or medical conditions. Numerous collaborations exist between the facility and NIH supported biomedical researchers that are outlined in this proposal covering areas as diverse as interferon resistance to hepatitis C, androgen dependence in prostate cancer, stem cell biology, identification of proteins associated with Tollike receptors, functional analysis of the Myc oncoprotein, cell-cycle regulation of gene expression in the yeast Saccharomyces cerevisiae, thymocyte biology, and analysis of the proteins associated with the T-ceIl regulatory protein LAT and associated phosphorylation events. In addition to these NIH supported projects another 12 collaborations are ongoing between the facility with collaborators inside and out of the ISB. The availability of FTMS instrumentation in the facility will allow more thorough characterization of individual proteins and their post-translational modifications (PTM) and whole proteomes for each of these projects than is possible with any of the other types of mass spectrometers present in the greater Seattle area. The unique features of non-destructive ion detection by FTMS instrumentation provide exceptional performance in three critical mass spectrometric parameters that will benefit our biomedical research: 1) mass accuracy of 0.1 -1.0 ppm at 1000 u allow higher confidence in identifications of proteins from peptides by, for instance, the mass fingerprint approach, 2) mass resolution of >1 00,000 (50% mIDm) at 1000 u provides extraordinary capability in the area of complex mixture characterization where as many as 3000 components have been detected in a crude oil mixture (REF Marshall) and 3) signal-to-noise enhancement allows detection and fragmentation of peptides in the low attomole regime (Marshall). Data from an FTMS instrument in each of these three areas far exceeds the same capability from any other mass spectrometer that is currently available. Furthermore there are no FTMS instruments in the greater Seattle area for us, or our collaborators, to use.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biomedical Research Support Shared Instrumentation Grants (S10)
Project #
1S10RR017262-01
Application #
6500621
Study Section
Special Emphasis Panel (ZRG1-BECM (02))
Program Officer
Tingle, Marjorie
Project Start
2003-08-01
Project End
2005-07-31
Budget Start
2003-08-01
Budget End
2005-07-31
Support Year
1
Fiscal Year
2003
Total Cost
$782,028
Indirect Cost
Name
Institute for Systems Biology
Department
Type
DUNS #
135646524
City
Seattle
State
WA
Country
United States
Zip Code
98109
Hengel, Shawna M; Goodlett, David R (2012) A Review of Tandem Mass Spectrometry Characterization of Adenosine Diphosphate-Ribosylated Peptides. Int J Mass Spectrom 312:114-121
Hengel, Shawna Mae; Murray, Euan; Langdon, Simon et al. (2011) Data-independent proteomic screen identifies novel tamoxifen agonist that mediates drug resistance. J Proteome Res 10:4567-78
Heron, Scott R; Wilson, Rab; Shaffer, Scott A et al. (2010) Surface acoustic wave nebulization of peptides as a microfluidic interface for mass spectrometry. Anal Chem 82:3985-9
Nunn, Brook L; Aker, Jocelyn R; Shaffer, Scott A et al. (2009) Deciphering diatom biochemical pathways via whole-cell proteomics. Aquat Microb Ecol 55:241-253
Hengel, Shawna M; Shaffer, Scott A; Nunn, Brook L et al. (2009) Tandem mass spectrometry investigation of ADP-ribosylated kemptide. J Am Soc Mass Spectrom 20:477-83
Gao, Quixia; Xue, Song; Shaffer, Scott A et al. (2008) Minimize the detection of false positives by the software program DetectShift for 18O-labeled cross-linked peptide analysis. Eur J Mass Spectrom (Chichester, Eng) 14:275-80
Shaffer, Scott A; Harvey, Megan D; Goodlett, David R et al. (2007) Structural heterogeneity and environmentally regulated remodeling of Francisella tularensis subspecies novicida lipid A characterized by tandem mass spectrometry. J Am Soc Mass Spectrom 18:1080-92
Foss, Eric J; Radulovic, Dragan; Shaffer, Scott A et al. (2007) Genetic basis of proteome variation in yeast. Nat Genet 39:1369-75
Gao, Qiuxia; Xue, Song; Doneanu, Catalin E et al. (2006) Pro-CrossLink. Software tool for protein cross-linking and mass spectrometry. Anal Chem 78:2145-9
Xu, Jing; Chen, Jinzhi; Peskind, Elaine R et al. (2006) Characterization of proteome of human cerebrospinal fluid. Int Rev Neurobiol 73:29-98

Showing the most recent 10 out of 12 publications