The objectives ofthe Dartmouth University U19 CMCR program are to develop field biodosimetry techniques that are based on ex vivo and in vivo electron paramagnetic resonance (EPR) spectrometry measurements of a radiation-induced signal (RIS) in finger/toe nails (""""""""nails"""""""") or teeth. In this project (2), the ex vivo EPR method for measuring nails is further developed towards a field deployable application. To achieve this goal, four objectives have been deflned that address signal characterization, sample treatment and signal deconvolution to remove interfering signals, validation of test methods, identification and characterization of factors that have the potential to impact the variability of the RIS signal, and establish methods for data acquisition, processing and output suitable for use by non-expert operators and ER managers under field conditions. Characterization ofthe overall signal, the spectral components and pursuing a systematic investigation of the molecular basis of the EPR signals in both unirradiated and irradiated nails is important towards developing approaches for separating the radiation-induced signal from a mechanically-induced signal (MIS). Some aspects of these studies will utilize the data from Project 3, which will provide EPR spectra of nails without clipping, and therefore help to differentiate more clearly the origin and nature of the signals from the clipping process. The result of this set of studies is the development of a basis set of spectral components ofthe RIS an MIS signals, coupled with the decay kinetics ofthe separate component signals that are integrated into a spectrum deconvolution procedure for extracting the RIS component signal. Variability in RIS and MIS signals are to be characterized with respect to nail water content, demographics (i.e. age, race), systemic variables (pregnancy, diet/supplements, nail disorders) and fungal infection. Finally, delineating a field-usable method for sample procurement, placement ofthe samples into the spectrometer, the analytic software to determine the dose, and delineation of factors that if present need to be considered in the calibration of the results. While the construction of a field-deployable prototype that meets the overall goals ofthe Center will be carried out in collaboration with the instrumental core at Dartmouth, this project will develop the methodology to be implemented in the development and construction.

Public Health Relevance

The objectives of the project provide the supporting data and method development necessary for fielding a biodosimeter that is based on measuring a dose dependent radiation induced signal in finger or toe nail clippings.

Agency
National Institute of Health (NIH)
Institute
National Institute of Allergy and Infectious Diseases (NIAID)
Type
Research Program--Cooperative Agreements (U19)
Project #
1U19AI091173-01
Application #
8013157
Study Section
Special Emphasis Panel (ZAI1-KS-I (M1))
Project Start
2010-08-15
Project End
2015-07-31
Budget Start
2010-08-15
Budget End
2011-07-31
Support Year
1
Fiscal Year
2010
Total Cost
$324,659
Indirect Cost
Name
Dartmouth College
Department
Type
DUNS #
041027822
City
Hanover
State
NH
Country
United States
Zip Code
03755
Flood, Ann Barry; Wood, Victoria A; Schreiber, Wilson et al. (2018) Guidance to Transfer 'Bench-Ready' Medical Technology into Usual Clinical Practice: Case Study - Sensors and Spectrometer Used in EPR Oximetry. Adv Exp Med Biol 1072:233-239
Swarts, Steven G; Sidabras, Jason W; Grinberg, Oleg et al. (2018) Developments in Biodosimetry Methods for Triage With a Focus on X-band Electron Paramagnetic Resonance In Vivo Fingernail Dosimetry. Health Phys 115:140-150
Kobayashi, Kyo; Dong, Ruhong; Nicolalde, Roberto Javier et al. (2018) Development of a novel mouth model as an alternative tool to test the effectiveness of an in vivo EPR dosimetry system. Phys Med Biol 63:165002
Shirley, Ben; Li, Yanxin; Knoll, Joan H M et al. (2017) Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation. J Vis Exp :
Sholom, Sergey; McKeever, Stephen (2017) Stability of X-band EPR signals from fingernails under vacuum storage. Radiat Phys Chem Oxf Engl 1993 141:78-87
Miyake, Minoru; Nakai, Yasuhiro; Yamaguchi, Ichiro et al. (2016) IN-VIVO RADIATION DOSIMETRY USING PORTABLE L BAND EPR: ON-SITE MEASUREMENT OF VOLUNTEERS IN FUKUSHIMA PREFECTURE, JAPAN. Radiat Prot Dosimetry 172:248-253
Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene et al. (2016) Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure. Health Phys 110:391-4
Sholom, S; McKeever, S W S (2016) Emergency EPR dosimetry technique using vacuum-stored dry nails. Radiat Meas 88:41-47
Kobayashi, Kyo; Dong, Ruhong; Nicolalde, Roberto Javier et al. (2016) Evolution and Optimization of Tooth Models for Testing In Vivo EPR Tooth Dosimetry. Radiat Prot Dosimetry 172:152-160
Flood, Ann Barry; Ali, Arif N; Boyle, Holly K et al. (2016) Evaluating the Special Needs of The Military for Radiation Biodosimetry for Tactical Warfare Against Deployed Troops: Comparing Military to Civilian Needs for Biodosimetry Methods. Health Phys 111:169-82

Showing the most recent 10 out of 39 publications