As a noninvasive method for measuring concentration and distribution of chemicals in the living brain MRS is an important tool for studying brain function and disorders. However, robust measurement of MRS signals requires highly sophisticated design, implementation and maintenance of various MRS techniques. MRS technology has been a very active research area, attracting major effort from top magnetic resonance research centers around the world. Clinical magnetic resonance imaging scanners optimized for performing structural and functional imaging studies also present daunting obstacles for MRS technical development. Most of the MRS protocols at NIH were developed and implemented by the MRS core under protocols 05-M-0144 (NCT00109174) and 11-M-0045 (NCT01266577). 1) Correction of baseline in short echo time proton MRS. To capture the entire metabolic profile of brain visible to proton MRS, data acquisition at short echo time is needed. At the same time the broad macromolecule baseline was also acquired. The macromolecule baseline contributes to Cremer Rao Lower Bound of the metabolite signals. To accurately quantify this effect in clinical short echo time MRS we have recently developed a method for determining the smoothness of baseline based on mean squared error of the baseline, leading to more objective and reliable determination of metabolite signals (Zhang et al., Magn Reson Med, in press, 2014). 2) Automatic correction of magnetic field inhomogeneity. It is essential to optimize the homogeneity of magnetic field for all MRS experiments because field inhomogeneity can easily destroy the critical separation of different chemicals. More importantly, an inhomogeneous field makes effective suppression of tissue water signal difficult, therefore making reliable detection of more dilute chemicals impossible. This is particularly the case for anatomical regions of interest to psychiatric research. We have optimized an automatic shimming method based on fastmap which consistently out-performs the automatic shimming methods provided by MRI scanner manufacturers. It has already greatly improved the quality of clinical MRS data acquired at NIH. 3) Multislice chemical shift imaging of NAA, creatine and choline-containing compounds. The MRS core maintains a chemical shift imaging technique for mapping distribution of the neuronal marker N-acetylaspartate at 3 Tesla. This method simultaneously generates images of N-acetylaspartate, creatine, and choline-containing compounds. 4) Glutathione detection. Glutathione is a marker for oxidative stress. Many psychiatric and neurological disoders (such as schizophrenia, Alzheimer's disease and stroke) are associated with abnormal glutathione levels. In collaboration with Steven Warach (NINDS) a glutathione editing method was developed on the Philip 3 Tesla scanner at the Suburban Hospital for studying stroke patients using adaptive linefitting. We have also developed a single-shot method for measuring glutathione at 7 Tesla. 5) Carbon-13 MRS. By using carbon-13 labeled glucose or the glial-specific substrate acetate, brain energetics and glutamate and glutamine cycling flux can be measured. Previously we invented a method for carbon-13 MRS by combining low power stochastic decoupling and intravenous infusion of glucose with a carbon-13 label at the C2 position. This strategy makes it possible to perform viable carbon-13 MRS on single channel clincial MRI scanners. Using this strategy, we have acquired high quality carbon-13 MRS data from both the occipital and frontal lobes of healthy subjects and showed that it is possible to simultaneously detect two labeling pathways in the human brain. Recently, we have succeeded in implementing this strategy on the 7 Tesla scanner with enhanced sensitivity and spectral resolution. In particular, we are the first to detect GABA turnover in the human brain. 6) Proton glutamate editing. Previously we implemented a single-voxel glutamate editing method with correction of eddy current effects for measuring glutamate concentration at 3 Tesla. Recently, we have developed a new glutamate editing method which needs a single echo time to isolate the glutamate H4 signal at 7 Tesla. 7) GABA editing. Previously we implemented and refined a method for measuring GABA. Similar to N-acetylaspartate imaging, patient movements can lead to difficulty in accurate determination of GABA. A navigator strategy based on residual water was used to track and correct for patient movement. Special data processing software was also developed to correct for phase changes because of patient motion. The improvements of the corrections have been quantified and applied to studies of human subjects. Currently, we are quantifying glutamate concentration using GABA-edited spectral data. The goal of this effort is to simultaneously measure both GABA and glutamate. 8) NAAG editing. We have successfully developed MRS methods for measuring the dipeptide neurotransmitter N-acetylaspartylglutamate (NAAG) which plays an important role in glutamate signaling. Our methods use regularized lineshape deconvolution based on the L-curve method and Wiener filtering to reliably measure NAAG.

Agency
National Institute of Health (NIH)
Institute
National Institute of Mental Health (NIMH)
Type
Scientific Cores Intramural Research (ZIC)
Project #
1ZICMH002894-09
Application #
9152156
Study Section
Project Start
Project End
Budget Start
Budget End
Support Year
9
Fiscal Year
2015
Total Cost
Indirect Cost
Name
U.S. National Institute of Mental Health
Department
Type
DUNS #
City
State
Country
Zip Code
Evans, Jennifer W; Lally, Níall; An, Li et al. (2018) 7T 1H-MRS in major depressive disorder: a Ketamine Treatment Study. Neuropsychopharmacology 43:1908-1914
Li, Shizhe; An, Li; Duan, Qi et al. (2018) Determining the Rate of Carbonic Anhydrase Reaction in the Human Brain. Sci Rep 8:2328
An, Li; Araneta, Maria Ferraris; Johnson, Christopher et al. (2018) Simultaneous measurement of glutamate, glutamine, GABA, and glutathione by spectral editing without subtraction. Magn Reson Med 80:1776-1786
Marenco, Stefano; Meyer, Christian; van der Veen, Jan Willem et al. (2018) Role of gamma-amino-butyric acid in the dorsal anterior cingulate in age-associated changes in cognition. Neuropsychopharmacology 43:2285-2291
Li, Ningzhi; Li, Shizhe; Shen, Jun (2017) Reconstruction of randomly under-sampled spectra for in vivo13C magnetic resonance spectroscopy. Magn Reson Imaging 37:216-221
van der Veen, Jan Willem; Marenco, Stefano; Berman, Karen F et al. (2017) Retrospective correction of frequency drift in spectral editing: The GABA editing example. NMR Biomed 30:
An, Li; Li, Shizhe; Shen, Jun (2017) Simultaneous determination of metabolite concentrations, T1 and T2 relaxation times. Magn Reson Med 78:2072-2081
Zhang, Yan; An, Li; Shen, Jun (2017) Fast computation of full density matrix of multispin systems for spatially localized in vivo magnetic resonance spectroscopy. Med Phys 44:4169-4178
Lally, Níall; An, Li; Banerjee, Dipavo et al. (2016) Reliability of 7T (1) H-MRS measured human prefrontal cortex glutamate, glutamine, and glutathione signals using an adapted echo time optimized PRESS sequence: A between- and within-sessions investigation. J Magn Reson Imaging 43:88-98
Li, Shizhe; An, Li; Yu, Shao et al. (2016) (13)C MRS of human brain at 7 Tesla using [2-(13)C]glucose infusion and low power broadband stochastic proton decoupling. Magn Reson Med 75:954-61

Showing the most recent 10 out of 36 publications