According to the CDC, among US men, cancer of the prostate is the most common type of cancer and the second leading cause of cancer death. Due to the diffuse nature of prostate cancer, there is a need for safe, inexpensive, and portable prostate tumor imaging, which MRI or nuclear imaging cannot satisfy. As one of the most sensitive in vivo molecular imaging modalities, fluorescence imaging has great potential to play an important role in preclinical and clinical studies. Indeed, in vivo fluorescence optical imaging extends across a wide range of applications, from cellular to organ levels. Unfortunately, in organ level applications, fluorescence imaging suffers from low resolution due to the high scattering nature of the biological tissue especially in deep tissue. Extensive effort has been spent to improve the resolution of fluorescence tomography (FT) by research groups from academia and industry in the last decade. However, approaches such as integrating FT with other anatomic imaging modalities such as MRI or CT does not perform well if the fluorescent target cannot be localized in the anatomical image. There are several techniques that attempt to modulate fluorescence signals using ultrasound to achieve higher resolution. However, low modulation efficiency and extremely low signal to noise ratio (SNR) are the two primary factors that make the implementation of these techniques difficult. Therefore, the low quantitative accuracy and resolution of fluorescence imaging remain as the main barriers for clinical translation of this powerful technique. To overcome these limitations, our main goal in this proposal is to develop an entirely new approach """"""""Temperature-modulated fluorescence tomography (TM-FT)"""""""" that can provide high resolution images at depths up to 6 cm without sacrificing the exceptional sensitivity of fluorescence-based detection. There are two key components to this highly innovative approach: a) Temperature sensitive florescent molecular probes (thermo-dots) and b) High Intensity Focused Ultrasound (HIFU) based modulation of tissue temperature (only 3-50C) with high spatial resolution. The small size of the focal spot (~1mm) allows imaging the distribution of these temperature sensitive agents with not only high spatial resolution but also high quantitative accuracy. Development of this novel system will include: development and optimization of the TM-FT reconstruction algorithm, development of the TM-FT system and evaluation with phantom studies, and finally, validation with in vivo studies. This training proposal is geared toward the first in vivo feasibility studies of this nove imaging modality. The outcome of this proposal could be a radiation free, cost-effective, and portable tumor imaging system. Mice bearing orthotopic prostate cancer model will be used to test the hypothesis that """"""""TM-FT will provide quantitatively more accurate and higher resolution fluorescence images compared to a stand-alone FT system"""""""". If successful, the outcome will be the beginning of a new imaging modality.

Public Health Relevance

Temperature Modulated Fluorescence Tomography: A New Modality for Cancer Imaging This training grant aims to develop a new molecular optical imaging modality termed """"""""Temperature Modulated Fluorescence Tomography (TM-FT)"""""""" that can provide high resolution images without sacrificing the exceptional sensitivity of fluorescence-based detection. The medium is irradiated by both excitation light and a high intensity focused ultrasound (HIFU) wave. HIFU will be used to modulate the temperature of the medium and locate temperature- sensitive fluorescent contrast agents a very high spatial resolution (~1.5 mm). With the TM-FT system developed in this training grant, high resolution and quantitative accuracy can be achieved for fluorescence imaging with deep tissue penetration. During the study, the feasibility of this novel platform will be evaluated in small animal models.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Predoctoral Individual National Research Service Award (F31)
Project #
1F31CA171915-01A1
Application #
8459898
Study Section
Special Emphasis Panel (ZRG1-F04-D (20))
Program Officer
Bini, Alessandra M
Project Start
2012-09-14
Project End
2015-09-13
Budget Start
2012-09-14
Budget End
2013-09-13
Support Year
1
Fiscal Year
2012
Total Cost
$35,293
Indirect Cost
Name
University of California Irvine
Department
Physics
Type
Schools of Arts and Sciences
DUNS #
046705849
City
Irvine
State
CA
Country
United States
Zip Code
92697
Nouizi, F; Erkol, H; Luk, A et al. (2016) An accelerated photo-magnetic imaging reconstruction algorithm based on an analytical forward solution and a fast Jacobian assembly method. Phys Med Biol 61:7448-7465
Nouizi, Farouk; Erkol, Hakan; Luk, Alex et al. (2016) Real-time photo-magnetic imaging. Biomed Opt Express 7:3899-3904
Lin, Yuting; Nouizi, Farouk; Kwong, Tiffany C et al. (2015) Simulation-based evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography. Appl Opt 54:7612-21