Wavefront guided corneal refractive surgeries, as well as implants and procedures to restore near-vision in presbyopic patients, require a knowledge of the optical, biometric and imaging properties of the lens. The optical properties of the human crystalline lens are determined by its shape and its refractive index gradient. These properties change with accommodation, which is the eye's ability to focus on near objects by changing the shape of the crystalline lens. The general goal of this study is to better understand the relationship between the refractive index gradient, the shape, specifically curvature and asphericity, of the human crystalline lens and its imaging properties, including paraxial optics as well as third and higher order aberrations. The working hypothesis is that when the shape of the lens changes during accommodation, there is a resulting change in both the asphericity and refractive index gradient that helps maintain the imaging quality produced by the lens. To demonstrate this hypothesis optical instrumentation will be developed to measure the shape, power and aberrations of ex vivo lenses during simulated accommodation in a lens stretching device developed in Dr. Parel's laboratory at Bascom Palmer Eye Institute. The results will be used to develop a higher-order dynamic optical model of the lens during accommodation.

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Predoctoral Individual National Research Service Award (F31)
Project #
5F31EY015395-04
Application #
7209804
Study Section
Special Emphasis Panel (ZRG1-SSS-C (29))
Program Officer
Araj, Houmam H
Project Start
2004-04-01
Project End
2008-12-18
Budget Start
2007-04-01
Budget End
2008-12-18
Support Year
4
Fiscal Year
2007
Total Cost
$25,272
Indirect Cost
Name
University of Miami Coral Gables
Department
Biomedical Engineering
Type
Schools of Engineering
DUNS #
625174149
City
Coral Gables
State
FL
Country
United States
Zip Code
33146
Siedlecki, Damian; de Castro, Alberto; Gambra, Enrique et al. (2012) Distortion correction of OCT images of the crystalline lens: gradient index approach. Optom Vis Sci 89:E709-18
de Castro, A; Siedlecki, D; Borja, David et al. (2011) Age-dependent variation of the Gradient Index profile in human crystalline lenses. J Mod Opt 58:1781-1787
Maceo, Bianca M; Manns, Fabrice; Borja, David et al. (2011) Contribution of the crystalline lens gradient refractive index to the accommodation amplitude in non-human primates: in vitro studies. J Vis 11:23
Borja, David; Manns, Fabrice; Ho, Arthur et al. (2010) Refractive power and biometric properties of the nonhuman primate isolated crystalline lens. Invest Ophthalmol Vis Sci 51:2118-25
Nankivil, Derek; Manns, Fabrice; Arrieta-Quintero, Esdras et al. (2009) Effect of anterior zonule transection on the change in lens diameter and power in cynomolgus monkeys during simulated accommodation. Invest Ophthalmol Vis Sci 50:4017-21
Urs, Raksha; Manns, Fabrice; Ho, Arthur et al. (2009) Shape of the isolated ex-vivo human crystalline lens. Vision Res 49:74-83
Borja, David; Manns, Fabrice; Ho, Arthur et al. (2008) Optical power of the isolated human crystalline lens. Invest Ophthalmol Vis Sci 49:2541-8
Uhlhorn, Stephen R; Borja, David; Manns, Fabrice et al. (2008) Refractive index measurement of the isolated crystalline lens using optical coherence tomography. Vision Res 48:2732-8
Ziebarth, Noel M; Borja, David; Arrieta, Esdras et al. (2008) Role of the lens capsule on the mechanical accommodative response in a lens stretcher. Invest Ophthalmol Vis Sci 49:4490-6
Manns, Fabrice; Parel, Jean-Marie; Denham, David et al. (2007) Optomechanical response of human and monkey lenses in a lens stretcher. Invest Ophthalmol Vis Sci 48:3260-8