The physiological significance of a coronary stenosis depends on the absolute minimal cross-sectional area of the stenotic lumen. In clinical studies, the results of videodensitometric analysis of specific types of coronary obstructions have been found to correlate well with lesion geometry, as defined by quantitative coronary angiography, and lesion physiological significance, as defined by intraoperative or intracoronary Doppler reactive hyperemia studies. However, more widespread application of videodensitometric techniques for analysis of coronary angiograms depends on evaluating the effects of many technical and physiological factors on the results of videodensitometric analysi. In addition, a method of defining absolute lumen area using videodensitometric techniques needs to be developed, and the technique needs to be made practical for use """"""""on line"""""""" in the cardiac catheterization laboratory where critical decisions based on coronary anatomy are frequently made, especially during cases of angioplasty or thrombolytic therapy. In the studies proposed here, there goals will be approached using an animalmodel of coronary stenosis. Coronary stenoses will be produced by placing radiolucent plastic cylinders, with internal lumens of varying sizes (1-10 mm-2) and shapes, into calf coronary arteries using nonsurgical, standard cardiac catheterization techniques. Coronary cineangiograms and digital coronary angiograms of the lesions will be taken and each angiogram will be analyzed using videodensitometric techniques. Study protocols will be performed to evaluate the effect of the following factors on the results of videodensitometric analysis: 1) factors which influence blood/contrast mixing, 2) angulation of the vessel in the field of view, 3) lesion shape, 4) mode of acquisition of angiographic information (i.e. cineangiographic vs. digital), 5) background correction techniques, 6) degrees and methods of magnification, and 7) the phase of the cardiac cycle during which the angiogram is acquired. An attempt will then be made to define absolute lumen areas using videodensitometric techniques by use of a contrast-filled calibration catheter or by comparison of the density value of the narrowed coronary artery segment to that of a normal-appearing segment, whose size can be more easily determined using quantitative angiographic techniques.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Clinical Investigator Award (CIA) (K08)
Project #
2K08HL000916-06
Application #
3081639
Study Section
(SRC)
Project Start
1981-07-01
Project End
1989-06-30
Budget Start
1986-07-01
Budget End
1987-06-30
Support Year
6
Fiscal Year
1986
Total Cost
Indirect Cost
Name
University of Iowa
Department
Type
Schools of Medicine
DUNS #
041294109
City
Iowa City
State
IA
Country
United States
Zip Code
52242
McPherson, D D; Johnson, M R; Collins, S M et al. (1993) Validation by high-frequency epicardial echocardiography of a new method of analyzing coronary angiography quantitatively in coronary artery disease. Am J Cardiol 71:28-32
McPherson, D D; Johnson, M R; Alvarez, N M et al. (1992) Variable morphology of coronary atherosclerosis: characterization of atherosclerotic plaque and residual arterial lumen size and shape by epicardial echocardiography. J Am Coll Cardiol 19:593-9
Fishman, J A (1989) Cross-reactive antigens of the rat and human Pneumocystis carinii. J Protozool 36:66S-67S
Johnson, M R; McPherson, D D; Fleagle, S R et al. (1988) Videodensitometric analysis of human coronary stenoses: validation in vivo by intraoperative high-frequency epicardial echocardiography. Circulation 77:328-36
Wilson, R F; Johnson, M R; Marcus, M L et al. (1988) The effect of coronary angioplasty on coronary flow reserve. Circulation 77:873-85
Johnson, M R; Skorton, D J; Ericksen, E E et al. (1988) Videodensitometric analysis of coronary stenoses. In vivo geometric and physiologic validation in humans. Invest Radiol 23:891-8
Feiring, A J; Johnson, M R; Kioschos, J M et al. (1987) The importance of the determination of the myocardial area at risk in the evaluation of the outcome of acute myocardial infarction in patients. Circulation 75:980-7
Johnson, M R; Brayden, G P; Ericksen, E E et al. (1986) Changes in cross-sectional area of the coronary lumen in the six months after angioplasty: a quantitative analysis of the variable response to percutaneous transluminal angioplasty. Circulation 73:467-75