Ice-embedded catalase crystals and amorphous carbon film were used as test specimens to demonstrate the feasibility and limitations of a 1024 x 1024 slow-scan CCD camera for imaging in a400 kV electron cryomicroscope. The structural resolution of the spot-scan images of ice-embedded catalase crystals was 8 _ and 4 _ at effective magnifications of 67,000x and 132,000x, respectively. These resolution limits are set by the finite pixel size of the slow-scan CCD camera. An amorphous carbon film was used to evaluate the damping effect of the specimen's Fourier spectrum by the modulation transfer function by comparing images of the same specimen area recorded on both the slow-scan CCD camera and photographic film. The ratio of the normalized diffraction amplitudes computed from these images becomes smaller at higher spatial frequency, showing that the Fourier amplitudes of CCD-recorded images fall off more rapidly, which is consistent with the expected modulation transfer function characteristics of the camera. Our analysis confirms the potential inaccuracies of the Fourier amplitudes in a certain range of spatial frequencies used for reconstruction if no correction is made on CCD captured images.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR002250-11
Application #
5223848
Study Section
Project Start
Project End
Budget Start
Budget End
Support Year
11
Fiscal Year
1996
Total Cost
Indirect Cost
Bucero, Marta Abril; Bajaj, Chandrajit; Mourrain, Bernard (2016) On the construction of general cubature formula by flat extensions. Linear Algebra Appl 502:104-125
Ebeida, Mohamed S; Rushdi, Ahmad A; Awad, Muhammad A et al. (2016) Disk Density Tuning of a Maximal Random Packing. Comput Graph Forum 35:259-269
Wensel, Theodore G; Zhang, Zhixian; Anastassov, Ivan A et al. (2016) Structural and molecular bases of rod photoreceptor morphogenesis and disease. Prog Retin Eye Res 55:32-51
Jeter, Cameron B; Patel, Saumil S; Morris, Jeffrey S et al. (2015) Oculomotor executive function abnormalities with increased tic severity in Tourette syndrome. J Child Psychol Psychiatry 56:193-202
Zhang, Qin; Cha, Deukhyun; Bajaj, Chandrajit (2015) Quality Partitioned Meshing of Multi-Material Objects. Procedia Eng 124:187-199
Baker, Mariah R; Fan, Guizhen; Serysheva, Irina I (2015) Single-particle cryo-EM of the ryanodine receptor channel in an aqueous environment. Eur J Transl Myol 25:35-48
Bettadapura, Radhakrishna; Rasheed, Muhibur; Vollrath, Antje et al. (2015) PF2fit: Polar Fast Fourier Matched Alignment of Atomistic Structures with 3D Electron Microscopy Maps. PLoS Comput Biol 11:e1004289
Baranovskiy, Andrey G; Zhang, Yinbo; Suwa, Yoshiaki et al. (2015) Crystal structure of the human primase. J Biol Chem 290:5635-46
Zhang, Zhixian; He, Feng; Constantine, Ryan et al. (2015) Domain organization and conformational plasticity of the G protein effector, PDE6. J Biol Chem 290:12833-43
Baker, Mariah R; Fan, Guizhen; Serysheva, Irina I (2015) Single-Particle Cryo-EM of the Ryanodine Receptor Channel in an Aqueous Environment. Eur J Transl Myol 25:4803

Showing the most recent 10 out of 213 publications