Flexor tendon injuries are one of the most common and difficult-to-treat hand traumas causing considerable functional loss and economic burden. Hand traumas are estimated to account for over 10% of total emergency department visits. For the past half-century, flexor tendon reconstruction has been a major surgical procedure to restore hand function following flexor tendon injuries. However, clinical outcomes remain frustratingly unsatisfactory and are marred by a high rate of complications, including adhesion and poor digit function following reconstruction. These unacceptable outcomes often result in multiple surgical revisions or even finger amputations that further prolong patient disability and increase medical costs. The overall goal of this project is to develop a clinically-applicable engineered tendon graft that could become an off-the-shelf, functionally superior alternative to the conventional tendon graft. In the first award period, we have developed strategies to improve the surface quality of the graft tendons using carbodiimide derivatized hyaluronic acid and lubricin, two important lubricating molecules. We found that this modification enhanced tendon gliding ability, decreased adhesions, and improved digit function using either extrasynovial autograft (clinical standard) or intrasynovial allograft (attractive alternative) transplantation. Encouragingly, our experiments in an in vitro model have allowed us to successfully enhance graft tendons using chemically modified native synovial fluid (SF) from joints, which is readily available and clinically applicable. Therefore, in this renewal, we will advance our project to test our hypothesis that synovialization of extrasynovial autograft using chemically modified autologous SF will improve the outcome of flexor tendon reconstruction in a clinically-relevant canine in vivo model as proposed in Specific Aim 1. If successful, this technique can be quickly translated to clinical practice, since both chemical modification and autologous synovial fluid can be safely applied clinically to tendon autograft. This technique can also be adopted in transplantation of other organs where adhesions are problematic. Furthermore, in an ex vivo model, we have developed a novel cell-based therapy that has potential to accelerate allograft regeneration, overcoming the slow revitalization we have encountered in the first funding period. Therefore in Specific Aim 2, we will combine chemical and tissue engineering approaches to synovialize and revitalize intrasynovial allograft tendon to generate a functionally superior alternative to the conventional tendon graft for flexor tendon reconstruction. If successful, these techniques can also be rapidly applied to clinical application since allograft tendons could be available off-the-shelf and revitalized and synovialized from patient's own joint fluid and cells. Considering the clinical significance of flexor tendon reconstruction, our novel and feasible approaches, supportive preliminary studies, reasonable hypotheses, and measurable outcomes, we are confident this proposal will be successful and has a significant clinical impact.

Public Health Relevance

Tendon injuries in the hand are common and difficult to treat, and tendon reconstruction is one of the primary surgical treatments to restore hand function. Unfortunately, poor clinical outcomes often result in multiple revision surgeries, or even finger amputations. This research proposal is to develop some novel treatments to improve the hand function following hand traumas which account for over 10% of all emergency department visits and result in a huge economic burden.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
3R01AR057745-06S1
Application #
9054277
Study Section
Musculoskeletal Tissue Engineering Study Section (MTE)
Program Officer
Wang, Fei
Project Start
2010-04-07
Project End
2019-08-31
Budget Start
2015-09-01
Budget End
2016-08-31
Support Year
6
Fiscal Year
2015
Total Cost
$240,885
Indirect Cost
$89,385
Name
Mayo Clinic, Rochester
Department
Type
DUNS #
006471700
City
Rochester
State
MN
Country
United States
Zip Code
55905
Cheng, Yu-Shiuan; Reisdorf, Ramona; Vrieze, Alyssa et al. (2018) Kinetic analysis of canine gait on the effect of failure tendon repair and tendon graft. J Biomech 66:63-69
Omi, Rei; Gingery, Anne; Steinmann, Scott P et al. (2016) Rotator cuff repair augmentation in a rat model that combines a multilayer xenograft tendon scaffold with bone marrow stromal cells. J Shoulder Elbow Surg 25:469-77
Qin, Ting-Wu; Sun, Yu-Long; Thoreson, Andrew R et al. (2015) Effect of mechanical stimulation on bone marrow stromal cell-seeded tendon slice constructs: a potential engineered tendon patch for rotator cuff repair. Biomaterials 51:43-50
Qu, Jin; van Alphen, Nick A; Thoreson, Andrew R et al. (2015) Effects of trypsinization and mineralization on intrasynovial tendon allograft healing to bone. J Orthop Res 33:468-74
Thoreson, Andrew R; Hiwatari, Ryo; An, Kai-Nan et al. (2015) The Effect of 1-Ethyl-3-(3-Dimethylaminopropyl) Carbodiimide Suture Coating on Tendon Repair Strength and Cell Viability in a Canine Model. J Hand Surg Am 40:1986-91
Ji, Xiaoxi; Bao, Nirong; An, Kai-Nan et al. (2015) A Canine Non-Weight-Bearing Model with Radial Neurectomy for Rotator Cuff Repair. PLoS One 10:e0130576
Ji, Xiaoxi; Chen, Qingshan; Thoreson, Andrew R et al. (2015) Rotator cuff repair with a tendon-fibrocartilage-bone composite bridging patch. Clin Biomech (Bristol, Avon) 30:976-80
Qu, Jin; Thoreson, Andrew R; An, Kai-Nan et al. (2015) What is the best candidate allograft for ACL reconstruction? An in vitro mechanical and histologic study in a canine model. J Biomech 48:1811-6
Ji, Xiaoxi; Reisdorf, Ramona L; Thoreson, Andrew R et al. (2015) Surface Modification with Chemically Modified Synovial Fluid for Flexor Tendon Reconstruction in a Canine Model in Vivo. J Bone Joint Surg Am 97:972-8
Wu, Jingheng; Thoreson, Andrew R; Reisdorf, Ramona L et al. (2015) Biomechanical evaluation of flexor tendon graft with different repair techniques and graft surface modification. J Orthop Res 33:731-7

Showing the most recent 10 out of 36 publications