The heart of the electronic medical imaging department that is fast evolving will be the workstation where the medical images are displayed for interpretation by the radiologist. We will investigate issues related to the desired properties of this workstation and the interpretation process of the radiologist in this environment. These investigations fall into two categories. First, an appropriate layout of the display station and effective layout, format, and manipulations of images must be determined. Second, a means of contrast enhancement that is both adequately convenient and effective for use with multi-image presentations must be established. We will compare the reading process and diagnostic capability of radiologists using film and different electronic displays, via both descriptive experiments involving eyetracking, videotaping, and interviewing, and quantitative observer studies. In particular, we will study the number and format of images that must be displayed simultaneously, the usefulness of spatial screen windows for presentation of a subset of the total set of images in a patient study, and the use of roam and zoom as a means of compensating for the inability to display the full image at full acquisition sampling. We will also evaluate the effectiveness of clipped adaptive histogram equalization (clahe) as the default display mode for slice-producing modalities of medical imaging and develop parameter values for this method as a function of medical image type and body region imaged. Using time-motion techniques standard in measuring computer-human interaction, we will investigate questions of the layout and selection of console screens and interactive devices and develop models of the process of navigating through large sets of medical images. Also, we will develop a complete design of special purpose VLSI-based hardware for the fast calculation of clahe and other image processing algorithms.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA044060-02
Application #
3186606
Study Section
(SSS)
Project Start
1986-12-05
Project End
1989-11-30
Budget Start
1987-12-01
Budget End
1988-11-30
Support Year
2
Fiscal Year
1988
Total Cost
Indirect Cost
Name
University of North Carolina Chapel Hill
Department
Type
Schools of Medicine
DUNS #
078861598
City
Chapel Hill
State
NC
Country
United States
Zip Code
27599
Hemminger, Bradley M; Bauers, Anne; Yang, Jian (2008) Comparison of navigation techniques for large digital images. J Digit Imaging 21 Suppl 1:S13-38
Hemminger, Bradley M; Molina, Paul L; Egan, Thomas M et al. (2005) Assessment of real-time 3D visualization for cardiothoracic diagnostic evaluation and surgery planning. J Digit Imaging 18:145-53
Hemminger, B M; Dillon, A W; Johnston, R E et al. (1999) Effect of display luminance on the feature detection rates of masses in mammograms. Med Phys 26:2266-72
Beard, D V; Molina, P L; Muller, K E et al. (1995) Interpretation time of serial chest CT examinations with stacked-metaphor workstation versus film alternator. Radiology 197:753-8
Hemminger, B M; Johnston, R E; Rolland, J P et al. (1995) Introduction to perceptual linearization of video display systems for medical image presentation. J Digit Imaging 8:21-34
Beard, D V; Hemminger, B M; Pisano, E D et al. (1994) Computed tomography interpretations with a low-cost workstation: a timing study. J Digit Imaging 7:133-9
Beard, D V; Hemminger, B M; Denelsbeck, K M et al. (1994) How many screens does a CT workstation need? J Digit Imaging 7:69-76
Beard, D V; Pisano, E D; Denelsbeck, K M et al. (1994) Eye movement during computed tomography interpretation: eyetracker results and image display-time implications. J Digit Imaging 7:189-92
Beard, D V; Hemminger, B M; Perry, J R et al. (1993) Interpretation of CT studies: single-screen workstation versus film alternator. Radiology 187:565-9
Beard, D V; Hemminger, B M; Keefe, B et al. (1993) Real-time radiologist review of remote ultrasound using low-cost video and voice. Invest Radiol 28:732-4

Showing the most recent 10 out of 15 publications