Our goal of the proposed research is to develop a highly accurate and reproducible method to assess the severity of stenotic lesions in coronary arteriograms as well as in digital subtraction angiographic (DSA) images. The geometrical and functional parameters of stenotic lesions will be determined from opacified vessel images by using an iterative deconvolution technique and cross-correlation of the vessel contrast distributions along the vessel segment, i.e., the """"""""distance-density"""""""" curves. We believe that our method will provide an accurate anatomical assessment of atherosclerosis regression or progression in stenotic lesions as well as accurate dimensions of normal vessels, with which a reliable blood flow rate from angiograms can be determined for evaluation of hemodynamic characteristics of stenotic lesions. Specifically, we plan to develop methods for quantitative analysis of stenotic lesions using an iterative deconvolution technique on coronary arteriograms, by incorporating a sector search method for tracking of vessel segments, correction of nonuniform background trend using a 2D surface fitting technique, and analysis of symmetry in vessel profiles. For biplane images, the location and orientation of the vessel segment will be determined using self-calibration technique for the determination of 3D vascular structure. Instantaneous and average blood flow rates in the selected vessel segments will be determined from analysis of the spatial shift of the distance- density curves of the vessel segment, which will be identified over a number of image frames based on the hierarchical vascular tree structure. Basic vessel information on vessel sizes, contrasts, and locations of opacified vessels will be obtained by means of automated tracking of vessel images based on the double-square-box region-of-search method. The hierarchical vascular tree structure will be constructed based on branching relationships between vessels and on basic vessel information. The 3D vascular structure in biplane angiography will be constructed without prior knowledge of the relationship between the two views. The relative geometry of the biplane imaging system will be determined from biplane image coordinates of eight or more object points of unknown 3D locations.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
2R01CA047043-04
Application #
3190503
Study Section
Diagnostic Radiology Study Section (RNM)
Project Start
1987-08-01
Project End
1995-05-31
Budget Start
1990-08-01
Budget End
1991-05-31
Support Year
4
Fiscal Year
1990
Total Cost
Indirect Cost
Name
University of Chicago
Department
Type
Schools of Medicine
DUNS #
225410919
City
Chicago
State
IL
Country
United States
Zip Code
60637
Hoffmann, K R; Esthappan, J (1997) Determination of three-dimensional positions of known sparse objects from a single projection. Med Phys 24:555-64
Doi, K; Giger, M L; Nishikawa, R M et al. (1995) Potential usefulness of digital imaging in clinical diagnostic radiology: computer-aided diagnosis. J Digit Imaging 8:2-7
Hoffmann, K R; Metz, C E; Chen, Y (1995) Determination of 3D imaging geometry and object configurations from two biplane views: an enhancement of the Metz-Fencil technique. Med Phys 22:1219-27
Giger, M L; Doi, K; MacMahon, H et al. (1993) An ""intelligent"" workstation for computer-aided diagnosis. Radiographics 13:647-56
Doi, K; Giger, M L; Nishikawa, R M et al. (1993) Digital radiography. A useful clinical tool for computer-aided diagnosis by quantitative analysis of radiographic images. Acta Radiol 34:426-39
Chen, X; Doi, K; Katsuragawa, S et al. (1993) Automated selection of regions of interest for quantitative analysis of lung textures in digital chest radiographs. Med Phys 20:975-82
Doi, K; Giger, M L; MacMahon, H et al. (1992) Computer-aided diagnosis: development of automated schemes for quantitative analysis of radiographic images. Semin Ultrasound CT MR 13:140-52
Hoffmann, K R; Chen, C T; Doi, K (1991) Automated region identification and its application to measuring cardiac function. Am J Card Imaging 5:272-80
Hoffmann, K R; Doi, K; Fencil, L E (1991) Determination of instantaneous and average blood flow rates from digital angiograms of vessel phantoms using distance-density curves. Invest Radiol 26:207-12
Metz, C E; Fencil, L E (1991) Extraction of three-dimensional information from biplane images without prior knowledge of the relative geometry of the two views. Prog Clin Biol Res 363:257-70

Showing the most recent 10 out of 15 publications