The purpose of these studies is to develop and evaluate a practical screening method for nodular disease using dual-energy chest radiography. The dual-energy technique is used to subtract either bone or soft-tissue structures from a radiographic image, by utilizing the different energy dependence of X-ray attenuation in bone and soft-tissue. The technique uses images acquired at two different X-ray energies to solve for the bone and soft-tissue components. The diagnostic advantages of dual-energy are that the visibility of soft-tissue nodules is improved by eliminating the presence of overlying ribs, and the calcium content of nodules may be determined by viewing the bone image. The dual-energy images are acquired simultaneously with a conventional radiograph, with little or no increase in patient dose, thereby making possible a clinically practical screening procedure. The resulting dual-energy images may be reviewed manually by a radiologist, and possibly in the future may be processed by automated nodule detection schemes to identify for further review those patients with potential nodules. The projects in this competing continuation application refine the dual- energy screening techniques developed in years 1-3 of the present grant. The specific studies in this proposal include: refinement of a new scatter-correction algorithm, refinement of noise-reduction algorithms, evaluation of new asymmetric screen-film cassettes for acquiring the complementary conventional image, evaluation of a new two-plate computed radiography approach for producing the complementary conventional image, detailed evaluation of image quality in dual-energy images, clinical evaluation of nodule detection using the hybrid conventional/dual-energy configuration, and evaluation of nodule detection using artificial neural networks to determine if dual-energy imaging provides improved specificity for computer-aided detection. In each of these areas of research, emphasis will be placed on detailed evaluation of technical improvement, practicality of implementation, and clinically-related diagnostic improvement.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA055388-05
Application #
2330800
Study Section
Diagnostic Radiology Study Section (RNM)
Project Start
1992-04-22
Project End
1999-01-31
Budget Start
1997-02-15
Budget End
1998-01-31
Support Year
5
Fiscal Year
1997
Total Cost
Indirect Cost
Name
Duke University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
071723621
City
Durham
State
NC
Country
United States
Zip Code
27705
Warp, Richard J; Dobbins 3rd, James T (2003) Quantitative evaluation of noise reduction strategies in dual-energy imaging. Med Phys 30:190-8
Althof, R J; Wind, M G; Dobbins 3rd, J T (1997) A rapid and automatic image registration algorithm with subpixel accuracy. IEEE Trans Med Imaging 16:308-16
Hinshaw, D A; Dobbins 3rd, J T (1996) Plate scatter correction for improved performance in dual-energy imaging. Med Phys 23:871-6
Dobbins 3rd, J T (1995) Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems. Med Phys 22:171-81
Dobbins 3rd, J T; Ergun, D L; Rutz, L et al. (1995) DQE(f) of four generations of computed radiography acquisition devices. Med Phys 22:1581-93