The main goals of this investigation are to demonstrate the following: (1) For certain treatment sites, accurate dose distributions computed with the aid of high speed Monte Carlo (MC) methods, or possibly with """"""""non-local energy deposition"""""""" (NLED) models, will reveal over- and under-dosing and significant dose inhomogeneities relative to dose distributions computed with conventional models. The reason for the lack of accuracy of conventional models is their inability to account for the effect of the patient's internal inhomogeneities and surface irregularities on the lateral transport of radiation. (2) These deficiencies may be clinically significant and can be rectified using various techniques, especially intensity-modulated radiation therapy (IMRT), which provides greater control, facilitating the achievement of desired dose distributions. (3) Although acceptable accuracy may be achievable in many circumstances even with NLED models, ultimately a MC approach is the most appropriate one due to its universally higher accuracy, reliability and consistency of results and its potential to reduce the effort required to develop and implement dose computation systems. Achieving high accuracy of predicted dose with MC methods in acceptable times on affordable computers is now well within reach. A highly efficient MC code called PEREGRINE, developed at Lawrence Livermore National Laboratory, will be enhanced as necessary, adapted for intensity-modulated beams, tested dosimetrically, and integrated into the investigators' commercial 3D-RTP system (ADAC Pinnacle). To demonstrate the extent and magnitude of the problem, MC-based 3D conformal treatment plans will be compared with corresponding plans based on NLED and conventional dose computation methods. The plan evaluation and comparison process will utilize dose distribution displays, dose volume histograms, dose and dose-volume statistics and biophysical dose-response indices (TCP, NTCPs, equivalent uniform doses (EUDs)). Intensity distributions will be adjusted iteratively to minimize the differences between accurate (MC or NLED) dose distributions and conventional ones accepted as optimum for treatment. Special techniques will be developed for the efficient optimization of intensity distributions employing dose distributions computed with MC. The project is directed mainly at lung and head and neck sites involving cavities and complex bony struc-tures. However, sites for which surface curvature and surface dose are important may also benefit. It is hoped that in the long run the application of the proposed methods will lead to the escalation of tumor dose for the same or lower normal tissue toxicity and therefore to an overall improvement in outcome.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
1R01CA074158-01A1
Application #
2608164
Study Section
Special Emphasis Panel (ZRG2-SSS-1 (03))
Program Officer
Mahoney, Francis J
Project Start
1998-07-01
Project End
2001-06-30
Budget Start
1998-07-01
Budget End
1999-06-30
Support Year
1
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Virginia Commonwealth University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
City
Richmond
State
VA
Country
United States
Zip Code
23298
Lockhart, Catherine M; MacDonald, Lawrence R; Alessio, Adam M et al. (2011) Quantifying and reducing the effect of calibration error on variability of PET/CT standardized uptake value measurements. J Nucl Med 52:218-24
Keall, Paul J; Chock, Leah B; Jeraj, Robert et al. (2003) Image reconstruction and the effect on dose calculation for hip prostheses. Med Dosim 28:113-7
Keall, Paul J; Siebers, Jeffrey V; Libby, Bruce et al. (2003) Determining the incident electron fluence for Monte Carlo-based photon treatment planning using a standard measured data set. Med Phys 30:574-82
Keall, Paul J; Siebers, Jeffrey V; Jeraj, Robert et al. (2003) Radiotherapy dose calculations in the presence of hip prostheses. Med Dosim 28:107-12
Siebers, Jeffrey V; Lauterbach, Marc; Tong, Shidong et al. (2002) Reducing dose calculation time for accurate iterative IMRT planning. Med Phys 29:231-7
Jeraj, Robert; Keall, Paul J; Siebers, Jeffrey V (2002) The effect of dose calculation accuracy on inverse treatment planning. Phys Med Biol 47:391-407
Siebers, Jeffrey V; Keall, Paul J; Kim, Jong Oh et al. (2002) A method for photon beam Monte Carlo multileaf collimator particle transport. Phys Med Biol 47:3225-49
Beckham, W A; Keall, P J; Siebers, J V (2002) A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error. Phys Med Biol 47:3465-73
Siebers, Jeffrey V; Lauterbach, Marc; Keall, Paul J et al. (2002) Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization. Med Phys 29:952-9
Keall, P J; Kini, V R; Vedam, S S et al. (2001) Motion adaptive x-ray therapy: a feasibility study. Phys Med Biol 46:1-10

Showing the most recent 10 out of 23 publications