Studies performed over the past decade give evidence that for lung cancer, increased radiotherapy dose will lead to better local control and survival. Further studies show that the main lung cancer radiotherapy side effect, pneumonitis, can be significantly reduced by lowering the dose delivered to healthy lung tissue. Balancing these conflicting goals is difficult, especially since a lung tumor moves on average 1.5-2 cm with respiratory motion. This project aims to develop and implement a technique entitled 4D IMRT (4-Dimensional Intensity Modulated Radiation Therapy). The 4th dimension, or time, component of the technique means that the tumor motion is accounted for during the imaging, planning and delivery of radiation. Tracking the tumor with the radiation beam during treatment delivery allows a reduction in beam margin and consequently a reduction in the volume of healthy tissue exposed to a high dose. The IMRT component of the technique allows us to give a sufficiently high dose to the tumor and an acceptably low dose to the healthy lung tissue. We will investigate the hypotheses that 4D IMRT will lead to: 1. improved treatment plans compared with conventional IMRT, 2. reduced volumes of normal tissue exposed to injurious doses compared with conventional IMRT, 3. reduced delivery time compared with respiration-gated IMRT, 4. wider applicability than breath-hold techniques, and 5. higher accuracy in delivered dose distributions compared with conventional and respiration-gated techniques.Though the studies here will concentrate mainly on lung cancer, 4D IMRT is applicable to all sites affected by respiratory motion, including breast and liver cancer, and even cervix and prostate cancer.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA093626-04
Application #
6892114
Study Section
Radiation Study Section (RAD)
Program Officer
Deye, James
Project Start
2002-07-15
Project End
2006-04-18
Budget Start
2005-07-01
Budget End
2006-04-18
Support Year
4
Fiscal Year
2005
Total Cost
$284,744
Indirect Cost
Name
Virginia Commonwealth University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
105300446
City
Richmond
State
VA
Country
United States
Zip Code
23298
Shepherd, Ray W; Weiss, Elisabeth (2017) Convex Endobronchial Ultrasound-Guided Placement of Fiducial Markers in Central Lung Tumors. J Bronchology Interv Pulmonol 24:e25-e26
Kida, Satoshi; Bal, Matthieu; Kabus, Sven et al. (2016) CT ventilation functional image-based IMRT treatment plans are comparable to SPECT ventilation functional image-based plans. Radiother Oncol 118:521-7
Suh, Yelin; Murray, Walter; Keall, Paul J (2014) IMRT treatment planning on 4D geometries for the era of dynamic MLC tracking. Technol Cancer Res Treat 13:505-15
Yamamoto, Tokihiro; Kabus, Sven; Lorenz, Cristian et al. (2014) Pulmonary ventilation imaging based on 4-dimensional computed tomography: comparison with pulmonary function tests and SPECT ventilation images. Int J Radiat Oncol Biol Phys 90:414-22
Ge, Yuanyuan; O'Brien, Ricky T; Shieh, Chun-Chien et al. (2014) Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator. Med Phys 41:061703
Ravkilde, Thomas; Keall, Paul J; Grau, Cai et al. (2014) Fast motion-including dose error reconstruction for VMAT with and without MLC tracking. Phys Med Biol 59:7279-96
Steel, Harry; Pollock, Sean; Lee, Danny et al. (2014) The internal-external respiratory motion correlation is unaffected by audiovisual biofeedback. Australas Phys Eng Sci Med 37:97-102
Ravkilde, Thomas; Keall, Paul J; Grau, Cai et al. (2013) Time-resolved dose distributions to moving targets during volumetric modulated arc therapy with and without dynamic MLC tracking. Med Phys 40:111723
Pommer, Tobias; Falk, Marianne; Poulsen, Per R et al. (2013) Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy. Phys Med Biol 58:2349-61
Rottmann, J; Keall, P; Berbeco, R (2013) Markerless EPID image guided dynamic multi-leaf collimator tracking for lung tumors. Phys Med Biol 58:4195-204

Showing the most recent 10 out of 69 publications