The overall long-term objective of this project is to incorporate clinical decisions through interactive feedback into the inverse treatment planning process for intensity-modulated radiotherapy. The hypotheses are that this will (i) make the inverse planning process more effective and (ii) increase the clinical relevancy of optimized plans, introducing better tradeoffs between target coverage and sparing of healthy tissues. The new approaches to tackle this problem include multi-criteria optimization techniques and an interactive plan navigation tool for searching a pre-calculated treatment plan database. The idea of multi-criteria optimization in treatment planning is that multiple planning criteria in different critical structures and in the target volume can be controlled simultaneously. In contrast, in current inverse planning algorithms a single objective (score function) is maximized or minimized. This conventional optimization gives only limited control of the planning result, and major manual plan tweaking using trial and error is often necessary. For the new multi-criteria optimization, we will use both dose-based criteria and equivalent uniform doses (EUDs) as costlets. In addition, hard physical constraints will be considered in order not to deviate too much from the dose range for which clinical experience exists. An efficient algorithm will be developed to calculate a set of """"""""Pareto"""""""" treatment plans, which are defined as treatment plans in which one cannot improve the dose in one organ without compromising at least one other organ. All Pareto solutions for an individual patient will be stored as a """"""""Pareto front"""""""" in a treatment plan database. Pareto fronts generated with physical dose and EUD criteria will be compared and we will search for stable regions that are Pareto optimal with respect to both. With the help of a navigation tool, the clinician and treatment planner can then interactively and quickly find the most suitable plan in the database. The navigation will be monitored in order to get a better understanding of the clinical decision process. The proposed mathematical algorithm for the multi-criteria optimization is an adapted Newton barrier algorithm. The navigation tool will be based on a prototype that was used for a preliminary approach with linear objective functions. The new approach will be evaluated using challenging clinical cases.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA103904-02
Application #
6913606
Study Section
Radiation Therapeutics and Biology Study Section (RTB)
Program Officer
Deye, James
Project Start
2004-07-01
Project End
2008-04-30
Budget Start
2005-07-01
Budget End
2006-04-30
Support Year
2
Fiscal Year
2005
Total Cost
$250,305
Indirect Cost
Name
Massachusetts General Hospital
Department
Type
DUNS #
073130411
City
Boston
State
MA
Country
United States
Zip Code
02199
Khan, Fazal; Craft, David (2015) Three-dimensional conformal planning with low-segment multicriteria intensity modulated radiation therapy optimization. Pract Radiat Oncol 5:e103-11
Craft, David; Richter, Christian (2013) Deliverable navigation for multicriteria step and shoot IMRT treatment planning. Phys Med Biol 58:87-103
Salari, Ehsan; Wala, Jeremiah; Craft, David (2012) Exploring trade-offs between VMAT dose quality and delivery efficiency using a network optimization approach. Phys Med Biol 57:5587-600
Chen, Wei; Unkelbach, Jan; Trofimov, Alexei et al. (2012) Including robustness in multi-criteria optimization for intensity-modulated proton therapy. Phys Med Biol 57:591-608
Craft, David; McQuaid, Dualta; Wala, Jeremiah et al. (2012) Multicriteria VMAT optimization. Med Phys 39:686-96
Craft, David L; Hong, Theodore S; Shih, Helen A et al. (2012) Improved planning time and plan quality through multicriteria optimization for intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys 82:e83-90
Wala, Jeremiah; Salari, Ehsan; Chen, Wei et al. (2012) Optimal partial-arcs in VMAT treatment planning. Phys Med Biol 57:5861-74
Teichert, K; Suss, P; Serna, J I et al. (2011) Comparative analysis of Pareto surfaces in multi-criteria IMRT planning. Phys Med Biol 56:3669-84
Craft, David (2010) Calculating and controlling the error of discrete representations of Pareto surfaces in convex multi-criteria optimization. Phys Med 26:184-91
Nohadani, Omid; Seco, Joao; Bortfeld, Thomas (2010) Motion management with phase-adapted 4D-optimization. Phys Med Biol 55:5189-202

Showing the most recent 10 out of 38 publications