To date, internal emitter therapy has been guided by dose calculations based on stylized phantoms representing average individuals, and results for the most part have not been clinically meaningful. Validation of theoretical calculations of absorbed fractions and absorbed doses is an element that has been needed for such calculations. We propose the use of state-of-the-art quantitative SPECT imaging advances combined with Monte Carlo source transport calculations to provide accurate estimates of absorbed radiation dose to replace those available from current internal dose models. We will implement planar and SPECT reconstruction methods that compensate for attenuation, scatter, septal penetration, spatial resolution, and partial-volume effects to obtain accurate planar projection and voxel estimates of the cumulative activity, using a combined SPECT/CT nuclear medicine camera that permits near simultaneous acquisition of anatomic and functional 3D data, with minimal registration problems. We will determine the accuracy of activity estimation from the quantitative methods and reconstruction algorithms, through comparison of measured activity values in simple and complex anthropomorphic phantoms to known values. We will convert activity to radiation dose in a voxel environment using well established Monte Carlo transport algorithms and compare the calculated doses to theoretical values, as well as values measured in phantoms and medium sized animals using implanted MOSFET minidosimeters. ? ?

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
1R01CA104907-01A1
Application #
6819149
Study Section
Radiation Therapeutics and Biology Study Section (RTB)
Program Officer
Baker, Houston
Project Start
2004-09-01
Project End
2007-08-31
Budget Start
2004-09-01
Budget End
2005-08-31
Support Year
1
Fiscal Year
2004
Total Cost
$302,226
Indirect Cost
Name
Vanderbilt University Medical Center
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
004413456
City
Nashville
State
TN
Country
United States
Zip Code
37212
Pereira, J M; Stabin, M G; Lima, F R A et al. (2010) Image quantification for radiation dose calculations--limitations and uncertainties. Health Phys 99:688-701
Liu, Shaoying; King, Michael A; Brill, Aaron B et al. (2008) Convolution-Based Forced Detection Monte Carlo Simulation Incorporating Septal Penetration Modeling. IEEE Trans Nucl Sci 55:967-974
Liu, Shaoying; King, Michael A; Brill, Aaron B et al. (2008) Accelerated SPECT Monte Carlo Simulation Using Multiple Projection Sampling and Convolution-Based Forced Detection. IEEE Trans Nucl Sci 55:560-567