The overall goal of this research project is to improve the accuracy and reliability of cone-beam computed tomography (CBCT) guidance of radiation treatment in lung and liver. The treatment of inoperable tumors in lung and liver remains a therapeutic challenge. Increasing the radiation dose improves local control but requires high-precision techniques. There is widespread interest in linear accelerator-mounted CBCT systems for guiding radiation treatment, but respiratory motion adversely affects CBCT image quality and limits its accuracy. We propose to develop and evaluate methods to reduce respiratory-induced motion artifacts in CBCT. Our hypotheses are: 1) motion-reduction techniques will improve tumor and organ-at-risk (OAR) visibility and localization accuracy in lung and liver, relative to current CBCT methods;2) motion-reduced CBCT will enable the use of contrast enhancement for localizing liver metastases at treatment, as an alternative to implanted fiducials;and 3) the improved localization accuracy will permit smaller treatment volumes, thereby enabling safe delivery of higher radiation doses.
Our specific aims are to 1) develop and validate a model of respiration-induced motion adapted to each patient from respiration-correlated CT and CBCT images;2) develop a method to reduce motion artifacts in CBCT using the patient-specific motion model;and 3) evaluate motion- reduced CBCT in patients treated with radiation for nonsmall cell lung cancer or liver metastases. The patient-specific motion model uses nonrigid image registration between CT or CBCT images at different respiratory motion states to generate 3D trajectories of all voxels in the volume images. An important component of the model is a principal component analysis that reduces the high-dimensional complex data set to a lower dimension by removing noise and redundancy. The motion reduction procedure sorts the CBCT projections into motion states according to the respiratory signal, reconstructs and morphs the volume image at each motion state to a reference image by means of the patient's motion model, then combines the morphed images to produce a high quality CBCT image. Evaluation of the accuracy of the proposed methods will use physical and analytical deformable phantoms, and manual delineations of clinical images. The first phase of patient studies will compare the ability to visualize and localize tumor and OAR before and after model-based motion reduction improvements to CBCT image quality, using gated CBCT as a reference. The imaging study in liver will test the feasibility of detecting metastatic lesions using motion-reduced CBCT in combination with intravenous contrast injection. The second phase of studies will use motion-reduced CBCT to correct patient position prior to hypofractionated radiotherapy in lung, and determine the fraction of patients for whom higher prescribed dose is achieved through margin reduction made possible by the improved localization accuracy.

Public Health Relevance

There is widespread interest in medical accelerator-mounted cone-beam computed tomography (CBCT) systems for improving the accuracy of radiation treatment;however, breathing motion can blur the images and limit our ability to locate and target tumors in lung and liver. We propose to develop methods to reduce blur and distortion in CBCT images caused by breathing motion. The effectiveness of these methods will be evaluated in patients receiving radiation treatment for lung cancer or liver metastases.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA126993-03
Application #
7802162
Study Section
Radiation Therapeutics and Biology Study Section (RTB)
Program Officer
Deye, James
Project Start
2008-07-01
Project End
2013-04-30
Budget Start
2010-05-01
Budget End
2011-04-30
Support Year
3
Fiscal Year
2010
Total Cost
$535,456
Indirect Cost
Name
Sloan-Kettering Institute for Cancer Research
Department
Type
DUNS #
064931884
City
New York
State
NY
Country
United States
Zip Code
10065
Kincaid Jr, Russell E; Hertanto, Agung E; Hu, Yu-Chi et al. (2018) Evaluation of respiratory motion-corrected cone-beam CT at end expiration in abdominal radiotherapy sites: a prospective study. Acta Oncol 57:1017-1024
Regmi, Rajesh; Lovelock, D Michael; Zhang, Pengpeng et al. (2015) Technical Note: Intrafractional changes in time lag relationship between anterior-posterior external and superior-inferior internal motion signals in abdominal tumor sites. Med Phys 42:2813-7
Regmi, Rajesh; Lovelock, D Michael; Hunt, Margie et al. (2014) Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: a feasibility study. Med Phys 41:071906
Dzyubak, Oleksandr; Kincaid, Russell; Hertanto, Agung et al. (2014) Evaluation of tumor localization in respiration motion-corrected cone-beam CT: prospective study in lung. Med Phys 41:101918
Zhao, Qingyu; Chou, Chen-Rui; Mageras, Gig et al. (2014) Local metric learning in 2D/3D deformable registration with application in the abdomen. IEEE Trans Med Imaging 33:1592-600
Chou, Chen-Rui; Frederick, Brandon; Mageras, Gig et al. (2013) 2D/3D Image Registration using Regression Learning. Comput Vis Image Underst 117:1095-1106
Kincaid Jr, Russell E; Yorke, Ellen D; Goodman, Karyn A et al. (2013) Investigation of gated cone-beam CT to reduce respiratory motion blurring. Med Phys 40:041717
McNamara, Joseph E; Regmi, Rajesh; Michael Lovelock, D et al. (2013) Toward correcting drift in target position during radiotherapy via computer-controlled couch adjustments on a programmable Linac. Med Phys 40:051719
Hertanto, Agung; Zhang, Qinghui; Hu, Yu-Chi et al. (2012) Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model. Med Phys 39:3070-9
Santoro, J P; McNamara, J; Yorke, E et al. (2012) A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer. Med Phys 39:5825-34

Showing the most recent 10 out of 15 publications