X-ray mammography has contributed to a reduction in mortality due to breast cancer. It is inherently limited, though, by its inability to directly observe physiological information relevant to the function of cancerous tissue. This ultimately limits the specificity and prognostic ability of x-ray mammography. Diffuse optical tomography (DOT) is a promising imaging modality that provides information on angiogenesis and hemoglobin oxygen saturation - key parameters tied to the presence and evolution of cancer. It suffers, however, from limited spatial resolution and unsatisfactory image quality due to optical coupling variations. These limitations inhibit straightforward interpretation of the optical images obtained and widespread clinical validation of DOT. This obstacle can be overcome by synergistically fusing the optical and x-ray information in a multi-modal imaging configuration - that is, by combining the two modalities, we can overcome their respective limitations and achieve a new multi-modality imaging method with enhanced specificity and prognostic value. Building upon our successful initial collaboration with Philips Healthcare and strong preliminary data, we propose to fundamentally address the current clinical limitations in x-ray mammography by developing a vendor- independent high-performance optical mammography co-imager, or OMCI, with which the optical measurements can be jointly reconstructed using the structural guidance from a separately acquired 2D or 3D digital x-ray mammogram. We believe that this approach has significant advantage from a clinical translation standpoint, as it directly capitalizes on the over 9,000 installed digital mammography systems in the US, and is expected to be compatible with future generations of mammography scanners. The proposed approach will dramatically reduce the time delays, costs, and complex regulatory pathways associated with developing and deploying integrated optical/mammography imaging systems. In the proposed study, we will build a new DOT system architecture for in vivo transmission human imaging and develop innovative prior-guided reconstruction algorithms to utilize high-density optical measurements and significantly enhance the optical image resolution and quality. Supported by a strong clinical team, we will perform a clinical study to explore the sensitivity an specificity of detecting malignant lesions using the proposed system. We will systematically compare the OMCI-assisted mammography diagnosis with stand-alone mammography through a blinded reader study to further confirm the clinical value of the added functional information. This result will prepare us for future multi- center trials and regulatory approval for this new device.

Public Health Relevance

The proposed study aims to develop a versatile high-performance optical mammography co-imager (OMCI) that can bring functional breast tumor diagnosis to any existing (and future) 2D or 3D x-ray digital mammography system worldwide. By developing advanced data-fusion algorithms to combine separately acquired optical and mammographic images, the proposed system has the strengths of both modalities and can produce anatomically guided functional breast images to facilitate the early discoveries of malignant breast tumors and help reduce the high false-positives resulted from standalone mammography.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA204443-02
Application #
9280887
Study Section
Medical Imaging Study Section (MEDI)
Program Officer
Baker, Houston
Project Start
2016-05-26
Project End
2021-04-30
Budget Start
2017-05-01
Budget End
2018-04-30
Support Year
2
Fiscal Year
2017
Total Cost
$307,600
Indirect Cost
$73,749
Name
Northeastern University
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
001423631
City
Boston
State
MA
Country
United States
Zip Code
02115
Draghici, Adina E; Potart, Diane; Hollmann, Joseph L et al. (2018) Near infrared spectroscopy for measuring changes in bone hemoglobin content after exercise in individuals with spinal cord injury. J Orthop Res 36:183-191
Deng, Bin; Lundqvist, Mats; Fang, Qianqian et al. (2018) Impact of errors in experimental parameters on reconstructed breast images using diffuse optical tomography. Biomed Opt Express 9:1130-1150
Horn, Andreas; Reich, Martin; Vorwerk, Johannes et al. (2017) Connectivity Predicts deep brain stimulation outcome in Parkinson disease. Ann Neurol 82:67-78
Sajjadi, Amir Y; Isakoff, Steven J; Deng, Bin et al. (2017) Normalization of compression-induced hemodynamics in patients responding to neoadjuvant chemotherapy monitored by dynamic tomographic optical breast imaging (DTOBI). Biomed Opt Express 8:555-569
Zimmermann, Bernhard B; Deng, Bin; Singh, Bhawana et al. (2017) Multimodal breast cancer imaging using coregistered dynamic diffuse optical tomography and digital breast tomosynthesis. J Biomed Opt 22:46008