With the worsening epidemic of chronic hepatitis B and C infections in the U.S., the rising incidence of cirrhosis is causing significant and growing morbidity and mortality. The limited number of livers available for transplantation means appropriate allocation of these precious resources is more critical than ever. Renal dysfunction is one of the most important risk factors for mortality in cirrhotics, as reflected by the inclusion of serum creatinine (Cr) in the MELD priority score for transplantation, and yet measures of renal function are highly inaccurate in cirrhosis. Estimators of GFR based on Cr and, more recently, cystatin C (CysC), overestimate renal function, leading to clinical mismanagement and suboptimal transplant prioritization. Over the past decade, we have developed 3D MR imaging and analysis tools for measuring glomerular filtration rate (GFR) using low doses of Gd contrast material and in less than 10 min of additional MR table time. Because of their propensity to develop hepatocellular carcinoma, cirrhotic patients undergo routine imaging for screening;of the imaging tests, MRI has proven most sensitive for early malignancy. We propose that during routine liver MRI, accurate measurements of GFR can be obtained for determining renal status in cirrhotic patients. Our preliminary MR GFR measurements, using a modified 2D protocol, show close agreement with reference 99mTc-DTPA clearance values in cirrhotics. Broad long term objectives: To develop and test an easily- implementable method for accurately measuring renal function in cirrhotic patients undergoing routine liver MRI.
Specific Aims /Methods: (1) To develop and refine a fast MRI method to measure single kidney and total glomerular filtration rate (GFR) that can be performed in conjunction with routine screening liver MR exams. With 15 subjects, we will compare accuracy of two methods for quantifying Gd concentration, perform a Gd dose optimization study, and examine the robustness of compartmental models of analysis. (2) To validate the accuracy of fast MR GFR methods compared with reference radionuclide clearance methods for single kidney and total GFR in a cirrhotic population of 197 subjects. We will compare MR GFR estimates with conventional Cr and CysC-based estimates (3) To develop and offer for public use a user-friendly graphical user interface to enable rapid (<5 min) analysis of MR renography data on standard, commonly available computer platforms. At its conclusion, our study is highly likely to show that MR renography can provide accurate measures of GFR quickly and accurately, and with negligible added costs when added to routine liver MRI. This project would have a high impact on human health by improving the management of cirrhotic patients, increasing the accuracy of risk stratification and MELD-based liver transplantation prioritization, and by reducing post-transplantation morbidity and mortality through the accurate monitoring of renal function, in addition to significant implications for the broader population of patients at risk for renal disease.

Public Health Relevance

The proposed project will be important for improving the health care of patients with liver diseases such as chronic hepatitis and cirrhosis, in whom kidney disease commonly develops but is frequently underdiagnosed. With the novel magnetic resonance imaging (MRI) technique that we propose, kidney function can be measured more accurately than available with existing methods, and can be integrated into the routine MRI screening protocol for liver cancer with negligible added time and costs. Potential implications of this more accurate measurement include better management of cirrhotic patients and improved prioritization for transplants as well as, more broadly, improved diagnosis of the broader population of patients who are at risk for developing kidney disease.

Agency
National Institute of Health (NIH)
Institute
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
Type
Research Project (R01)
Project #
1R01DK088375-01
Application #
7904712
Study Section
Medical Imaging Study Section (MEDI)
Program Officer
Flessner, Michael Francis
Project Start
2010-06-01
Project End
2015-05-31
Budget Start
2010-06-01
Budget End
2011-05-31
Support Year
1
Fiscal Year
2010
Total Cost
$582,867
Indirect Cost
Name
New York University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
121911077
City
New York
State
NY
Country
United States
Zip Code
10016
Conlin, Christopher C; Oesingmann, Niels; Bolster Jr, Bradley et al. (2017) Renal plasma flow (RPF) measured with multiple-inversion-time arterial spin labeling (ASL) and tracer kinetic analysis: Validation against a dynamic contrast-enhancement method. Magn Reson Imaging 37:51-55
Zhang, Jeff L; Conlin, Chris C; Carlston, Kristi et al. (2016) Optimization of saturation-recovery dynamic contrast-enhanced MRI acquisition protocol: monte carlo simulation approach demonstrated with gadolinium MR renography. NMR Biomed 29:969-77
Xie, Luke; Layton, Anita T; Wang, Nian et al. (2016) Dynamic contrast-enhanced quantitative susceptibility mapping with ultrashort echo time MRI for evaluating renal function. Am J Physiol Renal Physiol 310:F174-82
Conlin, Christopher C; Zhang, Jeff L; Rousset, Florian et al. (2016) Performance of an efficient image-registration algorithm in processing MR renography data. J Magn Reson Imaging 43:391-7
Zhang, Jeff L; Morrell, Glen; Rusinek, Henry et al. (2014) New magnetic resonance imaging methods in nephrology. Kidney Int 85:768-78
Kang, Stella K; Huang, William C; Lee, Vivian S et al. (2013) MR renographic measurement of renal function in patients undergoing partial nephrectomy. AJR Am J Roentgenol 200:1204-9
Kang, Stella K; Huang, William C; Wong, Samson et al. (2013) Dynamic contrast-enhanced magnetic resonance imaging measurement of renal function in patients undergoing partial nephrectomy: preliminary experience. Invest Radiol 48:687-92
Vivier, Pierre-Hugues; Storey, Pippa; Chandarana, Hersh et al. (2013) Renal blood oxygenation level-dependent imaging: contribution of R2 to R2* values. Invest Radiol 48:501-8
Zhang, Jeff L; Rusinek, Henry; Chandarana, Hersh et al. (2013) Functional MRI of the kidneys. J Magn Reson Imaging 37:282-93
Zhang, Jeff L; Sigmund, Eric E; Rusinek, Henry et al. (2012) Optimization of b-value sampling for diffusion-weighted imaging of the kidney. Magn Reson Med 67:89-97

Showing the most recent 10 out of 12 publications