This research is conducted jointly by Riverside Research Institute (RRI) and Weill Medical College of Cornell University (W1MC). Its long-term objective is to advance the diagnosis, treatment planning, and treatment monitoring of ocular diseases, primarily glaucoma, by interwoven engineering, and clinical studies. The program uses advanced methods to analyze radio-frequency (RF) echo signals and extract tissue information not available with conventional ultrasound systems. To examine anterior sections of the eye, novel very-high-frequency ultrasound (VHFU) annular arrays will be used with synthetic aperture and frequency-domain apodization; these will substantially improve resolution and depth-of-focus. Digital RF data will be acquired during multi-plane VHFU scanning of the entire anterior segment to construct highly detailed 3-D representations of structures involved in glaucoma and hypotony. Elements as small as 20-gm will be resolved. Biometric data (dimensions, surface areas, volumes) will be derived for relevant ocular compartments, including the anterior chamber and ciliary processes. Microstructure will be evaluated in terms of the effective sizes, concentrations, mechanical properties, and morphologic shapes of tissue constituents. Sizes of cell-level structures (15 gm) will be estimated to within 1 p.m to monitor changes related to function and therapy. These assays will use advanced 1-D and 2-D spectral techniques designed using a theoretical scattering model of tissue microstructure. The methods will be validated in laboratory and animal experiments. Measured features will be compared with light microscopy to elucidate sensitivity to specific microstructural elements. Animal and clinical studies will assess the utility of these methods for evaluating glaucoma, hypotony, and small anterior tumors undergoing treatment. Glaucoma studies will document ciliary body microanatomy and drug responses. Related studies will employ new high frequency transducers (20-30 MHz) and new morphological analysis techniques to examine posterior ocular structures. They will extract detailed tissue information from regions inaccessible to other imaging modalities. The methods will be clinically evaluated in cases of age-related macular generation.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB000238-32
Application #
7248735
Study Section
Special Emphasis Panel (ZRG1-DMG (90))
Program Officer
Lopez, Hector
Project Start
1996-12-06
Project End
2009-06-30
Budget Start
2007-07-01
Budget End
2009-06-30
Support Year
32
Fiscal Year
2007
Total Cost
$401,049
Indirect Cost
Name
Riverside Research Institute
Department
Type
DUNS #
046822615
City
New York
State
NY
Country
United States
Zip Code
10038
Coleman, D Jackson; Silverman, Ronald H; Rondeau, Mark J et al. (2013) Age-related macular degeneration: choroidal ischaemia? Br J Ophthalmol 97:1020-3
Kim, David Y; Silverman, Ronald H; Chan, Robison Vernon Paul et al. (2013) Measurement of choroidal perfusion and thickness following systemic sildenafil (Viagra(®) ). Acta Ophthalmol 91:183-8
Ursea, Roxana; Silverman, Ronald H (2010) Anterior-segment imaging for assessment of glaucoma. Expert Rev Ophthalmol 5:59-74
Reinstein, Dan Z; Gobbe, Marine; Archer, Timothy J et al. (2010) Epithelial, stromal, and total corneal thickness in keratoconus: three-dimensional display with artemis very-high frequency digital ultrasound. J Refract Surg 26:259-71
Reinstein, Dan Z; Archer, Timothy J; Gobbe, Marine et al. (2010) Epithelial thickness after hyperopic LASIK: three-dimensional display with Artemis very high-frequency digital ultrasound. J Refract Surg 26:555-64
Reinstein, Dan Z; Archer, Timothy J; Gobbe, Marine et al. (2010) Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner. J Refract Surg 26:646-59
Reinstein, Dan Z; Archer, Timothy J; Gobbe, Marine et al. (2009) Stromal thickness in the normal cornea: three-dimensional display with artemis very high-frequency digital ultrasound. J Refract Surg 25:776-86
Silverman, Ronald H; Patel, Monica S; Gal, Omer et al. (2009) Effect of corneal hydration on ultrasound velocity and backscatter. Ultrasound Med Biol 35:839-46
Reinstein, Dan Z; Archer, Timothy J; Silverman, Ronald H et al. (2009) Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound. J Refract Surg 25:185-94
Silverman, Ronald H (2009) High-resolution ultrasound imaging of the eye - a review. Clin Exp Ophthalmol 37:54-67

Showing the most recent 10 out of 30 publications