Current practice in radiotherapy struggles with the geometric uncertainties of treatment delivery.beam radiotherapy, such uncertainties arise from internal organ motiOn and setup errors, and, in brachytherapy these uncertainties are inherent to the invasive nature of the implant procedure. In either case, uncertainty can result in a geOgraphic miss of the targeted volume or, if margins are applied, a compromise in the prescription dose. Methods for improving therapeutic precision are clearly needed if radiotherapy is to be exploited to its fullest potential. In this proposal, a new imaging technology - flat-panel cone-beam CT (FPI-CBCT) - is evaluated for broad application in image-guided radiotherapy - allowing the therapist to acquire high quality, volumetric images during the therapy procedure. This approach improves therapeutic precision through imaging and feedback, providing guidance and assessment of the therapy procedure. FPI-CBCT is made possible by advances in two key technologies: cone-beam CT reconstruction methods, and the availability of flat-panel imagers (FPIs). In this proposal, the hypothesis that FPI-CBCT can satisfy the requirements for image-guidance in radiotherapy is tested through a systematic program of research.
In Specific Aim 1, the physical factors affecting FPI-CBCT are quantified and the dependence of these factors on geometry and mode of operation is determined.
In Specific Aim 2, a methodology for evaluating and predicting volumetric signal and noise transfer characteristics in FPI- CBCT is developed. Finally, Specific Aim 3 focuses the results of the first two aims to evaluate the imaging performance of FPI-CBCT for six clinically relevant image-guidance tasks. Successful completion of this program will identify an imaging solution that addresses the clinical need for image-guidance in radiation therapy.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB002470-05
Application #
6752152
Study Section
Special Emphasis Panel (ZRG1-RAD (02))
Program Officer
Haller, John W
Project Start
2001-03-01
Project End
2006-02-28
Budget Start
2004-03-01
Budget End
2006-02-28
Support Year
5
Fiscal Year
2004
Total Cost
$159,705
Indirect Cost
Name
Princess Margaret Hospital
Department
Type
DUNS #
City
Toronto
State
ON
Country
Canada
Zip Code
Moseley, Douglas J; White, Elizabeth A; Wiltshire, Kirsty L et al. (2007) Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate. Int J Radiat Oncol Biol Phys 67:942-53
Graham, S A; Moseley, D J; Siewerdsen, J H et al. (2007) Compensators for dose and scatter management in cone-beam computed tomography. Med Phys 34:2691-703
Purdie, Thomas G; Bissonnette, Jean-Pierre; Franks, Kevin et al. (2007) Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys 68:243-52
Sharpe, Michael B; Moseley, Douglas J; Purdie, Thomas G et al. (2006) The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator. Med Phys 33:136-44
Daly, M J; Siewerdsen, J H; Moseley, D J et al. (2006) Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype. Med Phys 33:3767-80
Islam, Mohammad K; Purdie, Thomas G; Norrlinger, Bernhard D et al. (2006) Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. Med Phys 33:1573-82
Munbodh, Reshma; Jaffray, David A; Moseley, Douglas J et al. (2006) Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement. Med Phys 33:1398-411
Siewerdsen, J H; Daly, M J; Bakhtiar, B et al. (2006) A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT. Med Phys 33:187-97
Hawkins, Maria A; Brock, Kristy K; Eccles, Cynthia et al. (2006) Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy. Int J Radiat Oncol Biol Phys 66:610-9
Siewerdsen, J H; Moseley, D J; Burch, S et al. (2005) Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. Med Phys 32:241-54

Showing the most recent 10 out of 14 publications