Minimally invasive procedures using endovascular access under x-ray fluoroscopic guidance have enabled treatment of patients that previously had no options. Even in patients who may be surgical candidates, minimally invasive procedures may be preferred because of their lower risk, faster recovery, and lower cost. Among these applications are the treatment of abdominal aortic aneurysms using stents and intracranial interventions with thrombolytic and embolic agents. Guidance using x-ray fluoroscopy is well-suited for many aspects of these procedures, however it is unable to depict a number of potential complications, such as endoleaks (which occur in 20-30% of aortic stents) or intracranial bleeding, nor to fully explore hemodynamic parameters such as blood volume. Often, patients require follow-up CT scans. While tomographic imaging using C-arms is being used for imaging high-contrast objects, basic problems have prevented these systems from providing sufficient low contrast sensitivity for a number of important tasks. We propose to greatly improve the low-contrast performance of C-arm CT, and thereby provide both x-ray fluoroscopy and much higher quality C-arm-based CT images during interventional procedures. The improved C-arm CT will bring low contrast resolution approaching that of conventional CT into the interventional lab and improve image guidance for these procedures. We will address problems such as scatter, under-sampling and beam hardening, and develop hardware and software to improve low-contrast detection with the specific goal of detecting a 10 mm object of 40 HU contrast (+/-10 HU noise). We will optimize acquisition and measurement protocols for the guidance of abdominal aortic stenting and intracranial interventions, and test these in vitro and in a porcine model. We expect to demonstrate the ability to depict the relationship among a stent and the vessel wall and thrombus, to visualize endoleaks, to estimate blood volume, and to detect fresh intracranial bleeds. The significance of this project is amplified by the fact that the technology developed here could eventually impact many other minimally invasive procedures.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
1R01EB003524-01
Application #
6766451
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Haller, John W
Project Start
2004-03-15
Project End
2007-01-31
Budget Start
2004-03-15
Budget End
2005-01-31
Support Year
1
Fiscal Year
2004
Total Cost
$419,483
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maier, Andreas; Hofmann, Hannes G; Berger, Martin et al. (2013) CONRAD--a software framework for cone-beam imaging in radiology. Med Phys 40:111914
Starman, Jared; Star-Lack, Josh; Virshup, Gary et al. (2012) A nonlinear lag correction algorithm for a-Si flat-panel x-ray detectors. Med Phys 39:6035-47
Maier, Andreas; Hofmann, Hannes G; Schwemmer, Chris et al. (2012) Fast simulation of x-ray projections of spline-based surfaces using an append buffer. Phys Med Biol 57:6193-210
Starman, Jared; Tognina, Carlo; Partain, Larry et al. (2012) A forward bias method for lag correction of an a-Si flat panel detector. Med Phys 39:18-27
Starman, Jared; Star-Lack, Josh; Virshup, Gary et al. (2011) Investigation into the optimal linear time-invariant lag correction for radar artifact removal. Med Phys 38:2398-411
Maier, Andreas; Wigstrom, Lars; Hofmann, Hannes G et al. (2011) Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT. Med Phys 38:5896-909
Yoon, Sungwon; Pineda, Angel R; Fahrig, Rebecca (2010) Simultaneous segmentation and reconstruction: a level set method approach for limited view computed tomography. Med Phys 37:2329-40
Gao, Hewei; Fahrig, Rebecca; Bennett, N Robert et al. (2010) Scatter correction method for x-ray CT using primary modulation: phantom studies. Med Phys 37:934-46
Prümmer, Marcus; Hornegger, Joachim; Lauritsch, Guenter et al. (2009) Cardiac C-arm CT: a unified framework for motion estimation and dynamic CT. IEEE Trans Med Imaging 28:1836-49
Al-Ahmad, Amin; Wigstrom, Lars; Sandner-Porkristl, Dominique et al. (2008) Time-resolved three-dimensional imaging of the left atrium and pulmonary veins in the interventional suite--a comparison between multisweep gated rotational three-dimensional reconstructed fluoroscopy and multislice computed tomography. Heart Rhythm 5:513-9

Showing the most recent 10 out of 19 publications