The primary objective for the proposed project is to develop a novel high-resolution (<10 5m), real-time and non-invasive optical imaging tool that is capable of comprehensive, simultaneous, and quantitative assessments of blood perfusion and tissue oxygen consumption within a scanned tissue volume up to 2 mm in depth without the use of labeling technique. Non-invasive and label-free imaging techniques for quantifying blood flow and blood oxygenation - down to capillary-level resolution - are of paramount importance for the improved understanding, diagnosis, and treatment of diseases that have peripheral vascular involvement, such as stroke, traumatic brain injury, hemorrhage, retinopathy, and cancer. Currently no optical imaging techniques are available that can offer simultaneous measurements of blood perfusion and oxygen consumption at a critical imaging depth (>1mm) within microcirculatory tissue beds in vivo. The proposed imaging tool - functional optical micro-angiography (fOMAG) - is a comprehensive and label- free volumetric imaging technology designed to simultaneously image and quantify blood perfusion and the oxygenation status of perfused blood within a scanned tissue volume. fOMAG will be designed to: 1) Image the detailed vessel architectures by separating endogenous optical signals backscattered from blood flow, from those endogenous optical signals backscattered from the tissue background (i.e. from bulk static tissue);2) Determine volumetric blood flow by employing a novel Doppler OMAG technique. This technique is based on the linear relationship between phase-changes in the optical fOMAG signals and the blood flow velocity when fOMAG images the tissue;3) Map the oxygenation status of the blood perfusion by a novel spectroscopic OMAG technique, which relies on the different molar extinction coefficients between the oxygenated and de- oxygenated hemoglobin in the near-infrared region at 800 nm wavelength band. The project will test the hypothesis that blood perfusion and oxygen consumption in tissues can be invasively and reliably imaged, quantified, and characterized simultaneously in real time, at 0- to 2-mm tissue depths and at a resolution of <10 5m.
The specific aims of the project are to: 1) construct an fOMAG imaging system, 2) develop a novel phase- resolved Doppler OMAG to quantify volumetric blood flow, 3) characterize a novel spectroscopic OMAG to image oxygen saturation in blood vessels, 4) validate fOMAG In vivo by volumetric imaging of cerebral blood perfusion in mice, and 5) investigate the utility of fOMAG for non-invasive transcranial monitoring of changes in cerebrovascular blood flow and healing-associated neovascularization after traumatic brain injury in mice.

Public Health Relevance

We propose to develop a novel biomedical imaging technology, functional optical micro-angiography that can provide the simultaneous, quantitative assessment of tissue blood perfusion and oxygen consumption within a scanned tissue volume in vivo non-invasively and without the use of labeling techniques. This novel imaging technique will become an important tool to investigate blood supply to tissues, and may help diagnosis, monitoring, and therapeutic interventions in diseases with vascular involvement.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
1R01EB009682-01
Application #
7697051
Study Section
Biomedical Imaging Technology Study Section (BMIT)
Program Officer
Zhang, Yantian
Project Start
2009-08-01
Project End
2013-06-30
Budget Start
2009-08-01
Budget End
2010-06-30
Support Year
1
Fiscal Year
2009
Total Cost
$460,481
Indirect Cost
Name
Oregon Health and Science University
Department
Engineering (All Types)
Type
Schools of Medicine
DUNS #
096997515
City
Portland
State
OR
Country
United States
Zip Code
97239
Park, Kwan S; Choi, Woo June; Song, Shaozhen et al. (2018) Multifunctional in vivo imaging for monitoring wound healing using swept-source polarization-sensitive optical coherence tomography. Lasers Surg Med 50:213-221
Li, David S; Lee, Yi-Ting; Xi, Yuyin et al. (2018) A small-angle scattering environment for in situ ultrasound studies. Soft Matter 14:5283-5293
Baran, U; Swanson, E; Sanders, J E et al. (2018) OCT-based microangiography for reactive hyperaemia assessment within residual limb skin of people with lower limb loss. Skin Res Technol 24:152-155
Baran, Utku; Choi, Woo June; Li, Yuandong et al. (2017) Tail artifact removal in OCT angiography images of rodent cortex. J Biophotonics 10:1421-1429
Li, David S; Yoon, Soon Joon; Pelivanov, Ivan et al. (2017) Polypyrrole-Coated Perfluorocarbon Nanoemulsions as a Sono-Photoacoustic Contrast Agent. Nano Lett 17:6184-6194
Qin, Wan; Roberts, Meredith A; Qi, Xiaoli et al. (2016) Depth-resolved 3D visualization of coronary microvasculature with optical microangiography. Phys Med Biol 61:7536-7550
Li, Yuandong; Choi, Woo June; Qin, Wan et al. (2016) Optical coherence tomography based microangiography provides an ability to longitudinally image arteriogenesis in vivo. J Neurosci Methods 274:164-171
Qin, Wan; Li, Yuandong; Wang, Jingang et al. (2016) In Vivo Monitoring of Microcirculation in Burn Healing Process with Optical Microangiography. Adv Wound Care (New Rochelle) 5:332-337
Baran, Utku; Qin, Wan; Qi, Xiaoli et al. (2016) OCT-based label-free in vivo lymphangiography within human skin and areola. Sci Rep 6:21122
Ambrozi?ski, ?ukasz; Song, Shaozhen; Yoon, Soon Joon et al. (2016) Acoustic micro-tapping for non-contact 4D imaging of tissue elasticity. Sci Rep 6:38967

Showing the most recent 10 out of 103 publications