Important progress has been made, with the help of NIEHS, toward effectively utilizing microwave induced plasma atomic emission spectrometry (MIP), as a means of detecting and quantifying chlorodioxin and other types of halocarbon samples such as insecticides. Particularly important to this progress has been the design and implementation of low flow torches (LFT; torches are plasma containment devices) which add enhanced stability and precision to the plasma detector. These torches have been initially characterized for their analytical figures of merit such as detection limit, linear response range, etc. This evidence suggests the analytical performance should be better than with previous studies involving the plasmas as GC detectors. It also suggests that suprathermal ionization (ionization in excess of that predicted by theoretical calculations) will be the normal course in operating the plasmas contained in the LFTs. As indicated in the text, the best detection levels for halocarbons such as dioxins or other organic compounds are in tenths-of-nanogram range, absolute, by GC-MIP or GC-mass spectrometry. Both of these methods allow selectivity and if operated in the appropriate mode lead to empirical formulae as well as quantitative trace analysis. To date having these valuable advantages has meant tradeoff of the sensitivity afforded by certain group sensitive detectors such as electron capture which is a factor of 10 or lower in detectability. GC-MIP can be an attractive alternative to GC-MS. A new approach which shows great promise is to utilize the ionizing capabilities of the plasma instead of its optical emission qualities. The limitations with optical emission come from the difficulty in enhancing signal/noise--S/N or signal to background--S/B, because at increased plasma power levels the optical background becomes more pronounced than the signal. If, however, we can successfully couple the MIP as an ion source to MS, and extract the ions efficiently, then detection levels should drop by a factor of 10-100, while preserving the important elemental analysis capabilities. This proposal then extends the previous work by markedly altering the plasma experiment as well as the usual GC-MS experiment to take advantage of the unique qualities of both. The plasma-MS experiments for metals with solution nebulization show one or two order of magnitude improvements easily. With non-metals the same or better should be possible. After all, the GC in effect removes most of the interfering matrix whereas solution nebulization does not.

Agency
National Institute of Health (NIH)
Institute
National Institute of Environmental Health Sciences (NIEHS)
Type
Research Project (R01)
Project #
5R01ES003221-05
Application #
3250393
Study Section
Metallobiochemistry Study Section (BMT)
Project Start
1983-06-15
Project End
1989-05-31
Budget Start
1987-06-01
Budget End
1988-05-31
Support Year
5
Fiscal Year
1987
Total Cost
Indirect Cost
Name
University of Cincinnati
Department
Type
Schools of Arts and Sciences
DUNS #
City
Cincinnati
State
OH
Country
United States
Zip Code
45221
Ding, H; Wang, J; Dorsey, J G et al. (1995) Arsenic speciation by micellar liquid chromatography with inductively coupled plasma mass spectrometric detection. J Chromatogr A 694:425-31
Lin, L; Wang, J; Caruso, J (1995) Arsenic speciation using capillary zone electrophoresis with indirect ultraviolet detection. J Chromatogr Sci 33:177-80
Tomlinson, M J; Lin, L; Caruso, J A (1995) Plasma mass spectrometry as a detector for chemical speciation studies. Analyst 120:583-9
Kumar, U T; Vela, N P; Caruso, J A (1995) Multi-element detection of organometals by supercritical fluid chromatography with inductively coupled plasma mass spectrometric detection. J Chromatogr Sci 33:606-10
Carey, J M; Vela, N P; Caruso, J A (1994) Chromium determination by supercritical fluid chromatography with inductively coupled plasma mass spectrometric and flame ionization detection. J Chromatogr A 662:329-40
Pretty, J R; Blubaugh, E A; Caruso, J A (1993) Determination of arsenic(III) and selenium(IV) using an on-line anodic stripping voltammetry flow cell with detection by inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. Anal Chem 65:3396-403
Vela, N P; Caruso, J A (1993) Comparison of flame ionization and inductively coupled plasma mass spectrometry for the detection of organometallics separated by capillary supercritical fluid chromatography. J Chromatogr 641:337-45
Kumar, U T; Dorsey, J G; Caruso, J A et al. (1993) Speciation of inorganic and organotin compounds in biological samples by liquid chromatography with inductively coupled plasma mass spectrometric detection. J Chromatogr A 654:261-8
Vela, N P; Olson, L K; Caruso, J A (1993) Elemental speciation with plasma mass spectrometry. Anal Chem 65:585A-597A
Sheppard, B S; Caruso, J A; Heitkemper, D T et al. (1992) Arsenic speciation by ion chromatography with inductively coupled plasma mass spectrometric detection. Analyst 117:971-5

Showing the most recent 10 out of 19 publications