Corneal transplantation is the most common solid organ transplantation worldwide, and immunological graft rejection is the main cause of graft failure. Corticosteroid eye drops must be applied frequently to prevent graft rejection and rescue grafts that show early signs of rejection, because topically administered drugs undergo rapid clearance and have poor ocular bioavailability. However, long-term, frequent dosing is associated with low patient compliance, and those that comply have risk of increased intraocular pressure (IOP), which can cause glaucoma. We propose a new method for providing sustained corticosteroid delivery at low, but efficacious levels, removing the treatment burden from patients and improving the safety of corticosteroids. We developed biodegradable nanoparticles containing high loadings of dexamethasone sodium phosphate (DSP) that can be administered by the same route that surgeons administer DSP at the end of corneal transplant surgery, subconjunctival (SCT) injection. Further, DSP-loaded nanoparticles (DSP-NP) are coated with polyethylene glycol (PEG) to minimize inflammatory reactions in the eye, and in contrast to topical drops, do not cause an increase in IOP in animal models. Our preliminary results demonstrate that DSP-NP are effective for both preventing and treating early signs of graft rejection in a rat model. Here, our aim is to develop longer- lasting formulations that can safely and effectively prevent and treat corneal graft rejection, for as long as 3 months with a single injection. If successful, this approach would significantly improve corneal transplant patient care and prognosis.
In Aim 1, we will confirm batch reproducibility, determine the maximum tolerated dose (MTD), and assess ocular pharmacokinetics (PK). The two lead formulations will then be tested for dose dependent efficacy for prevention and treatment in our rat model of graft rejection in Aim 2. Finally, we will carry out detailed safety and pharmacokinetics studies of at least one lead DSP-NP formulation in rabbits in Aim 3 to facilitate future development and potential clinical translation.

Public Health Relevance

Immunological graft rejection is the main cause of graft failure for corneal transplantation. Typical interventions for prevention of graft rejection are a subconjunctival (SCT) injection of corticosteroid at the end of surgery and a prescription for topical corticosteroid eye drops that must be frequently administered. When there are early signs of graft rejection, drop administration is even more frequent. Long-term, frequent topical use of corticosteroids leads to poor patient compliance, and for those that comply, risk of elevated intraocular pressure (IOP). Here, we describe a new method to provide sustained delivery of a common corticosteroid, dexamethasone sodium phosphate (DSP), by SCT administration to safely prevent and treat corneal graft rejection.

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Research Project (R01)
Project #
5R01EY027827-03
Application #
9709301
Study Section
Gene and Drug Delivery Systems Study Section (GDD)
Program Officer
Mckie, George Ann
Project Start
2017-09-30
Project End
2022-05-31
Budget Start
2019-06-01
Budget End
2020-05-31
Support Year
3
Fiscal Year
2019
Total Cost
Indirect Cost
Name
Virginia Commonwealth University
Department
Pharmacology
Type
Schools of Pharmacy
DUNS #
105300446
City
Richmond
State
VA
Country
United States
Zip Code
23298