The immunoassay continues to be an important bioanalytical technique for fundamental biological studies and clinical diagnosis. This proposal suggests a new approach to the heterogeneous assay involving the use of a microimmunoreactor column coupled to a flow injection analysis (FIA) system. The focus will be on the rapid analysis of small volume (10uL) samples with analyte concentrations in the sub-nanogram/mL range. The success of this approach will depend upon the availability of well- characterized immunochemical reagents of high activity. A series of synthetic procedures are described for coupling antibody or antibody fragments to a surface in a preferred orientation. This will encourage rapid reaction with soluble components and minimal non-specific interactions with the immunosorbent surface. The enzyme immunoassay forms the basis for detection, which is accomplished electrochemically or fluorometrically. The optimization of system performance requires a detailed understanding of the reactions occurring at the immunosorbent surface. The immunoreactor, which is in effect a flow reactor, can be used to study the kinetics of immunological reactions and to exploit differences in rates for analytical purposes. Monoclonal antibodies or mixtures of monoclonal antibodies will be used to obtain enhancement in selectivity. Heterobifunctional antibodies will be prepared which will permit linkage of two proteins without loss of biological activity. The techniques developed will be applied particularly to analysis of haptens in the sub-nanogram/mL range where the radioimmunoassay is normally employed. Two methods are proposed for non-competitive binding assays which should provide greater dynamic range and would be simpler to employ. Immunoassays will be developed for human cytokeratins. The distribution of these proteins in urine may be indicative of bladder cancer either as a cancerous or precancerous state.

Agency
National Institute of Health (NIH)
Institute
National Institute of General Medical Sciences (NIGMS)
Type
Research Project (R01)
Project #
1R01GM040038-01
Application #
3297339
Study Section
Metallobiochemistry Study Section (BMT)
Project Start
1987-08-01
Project End
1990-07-31
Budget Start
1987-08-01
Budget End
1988-07-31
Support Year
1
Fiscal Year
1987
Total Cost
Indirect Cost
Name
University of Kansas Lawrence
Department
Type
Schools of Arts and Sciences
DUNS #
072933393
City
Lawrence
State
KS
Country
United States
Zip Code
66045
DeSilva, B S; Wilson, G S (1995) Solid phase synthesis of bifunctional antibodies. J Immunol Methods 188:9-19
Hendrickson, T L; Wilson, G S; Frazer, J M et al. (1994) Enhanced immunogenicity of leucine enkephalin following coupling to anti-immunoglobulin and anti-CD3 antibodies. J Immunol Methods 172:165-72
Hendrickson, T L; Wilson, G S (1994) Improved clean-up method for the enkephalins in plasma using immunoaffinity chromatography. J Chromatogr B Biomed Appl 653:147-54
Gunaratna, P C; Wilson, G S (1993) Noncompetitive flow injection immunoassay for a hapten, alpha-(difluoromethyl)ornithine. Anal Chem 65:1152-7
Fernando, S A; Wilson, G S (1992) Multiple epitope interactions in the two-step sandwich immunoassay. J Immunol Methods 151:67-86
Gunaratna, P C; Wilson, G S (1992) Use of monoclonal anti-enzyme antibodies for analytical purposes. Biotechnol Prog 8:268-74
Fernando, S A; Wilson, G S (1992) Studies of the 'hook' effect in the one-step sandwich immunoassay. J Immunol Methods 151:47-66
Fernando, S A; Sportsman, J R; Wilson, G S (1992) Studies of the low dose 'hook' effect in a competitive homogeneous immunoassay. J Immunol Methods 151:27-46
Wimalasena, R L; Wilson, G S (1991) Factors affecting the specific activity of immobilized antibodies and their biologically active fragments. J Chromatogr 572:85-102
Meiklejohn, B; Nagle, R B; McDaniel, K M et al. (1990) Improved methods for separation of human cytokeratins. Life Sci 47:637-45

Showing the most recent 10 out of 12 publications