Mechanosensitive ion channels (MSCs) are membrane-bound proteins that let water and solute molecules flow in and out of the cell in response to membrane deformation (23). They are essential to life by letting the cell respond to osmotic changes (24). Eukaryotic MSCs are involved in sensory modalities, like touch, sound, fluid balance, and blood pressure (15,25). Problems with these channels are implicated in cardiac arrhythmia, muscular dystrophy, glioma, pathological pain, neurovestibular disturbances, and tumour metastasis (13,26- 28). MSCs (of large conductance, MscL, and of small conductance, MscS) from bacteria are best understood. This may aid in attacking bacteria via antibiotics (29) and may help understand the eukaryotic MSCs, which are poorly characterized (30). Yet vital information about the bacterial MSCs and especially eukaryotic MSCs, are missing. For the bacterial channels, the MscL channel has been crystallized in the closed form, but not in the open form (31). The open pore of the MscL has been experimentally tested via several ensemble techniques, including EPR and ensemble FRET, but systematic errors likely result in an overestimation (32), or an underestimation (33,34), or have not been sensitive to the requisite distances (35). We propose to study the open and closed states of MscL using single molecule fluorescence energy transfer (smFRET), a technique I helped to invent (36,37). This will be supplemented with molecular dynamics, led by Klaus Schulten (U. Illinois, Urbana-Champaign) (38,39) who has studied the MscL/MscS channels (1,3,4,6,7). Our other collaborator, Boris Martinac (Victor Chang Institute, Australia) has extensively studied the MscL/MscS (32-35,40-46). We will study how the MscL opens. The leading candidates are the barrel-stave model, with one transmembrane helices (TM1) moving, and the helix-tilt model (47), with two helices (TM1 and TM2) moving. (47). We have formed the MscL channel in both the open and closed state, and find that smFRET indicates that both helices move, leading to a change in the pore diameter of 2.8 nm. We therefore argue strongly for the helix-tilt model. We also propose to study the behavior of the cytoplasmic (CP) helix, a source of significant controversy (48,49). We have preliminary smFRET data, which argues that the CP domain is dissociated. Furthermore, we propose to investigate the interaction between the channel and its surrounding membrane by studying the conformational dynamics of the channel using a mutant (G22N) (49) which spontaneously opens and closes. We also propose to investigate the process of channel opening by independent MD simulations for which we have successfully simulated the opening of the pore by forcing water through the channel. Finally, in collaboration with Philip Gottlieb, SUNY, Buffalo, we have preliminary results on a huge (>1 MD) eukaryotic MSC, called (tetrameric) Piezo1 (12,30,50). We use both SimPull (17) to isolate a single channel, and super-resolution fluorescence techniques, gSHRImP (18,51) and SHREC (19) (derived from my FIONA technique (20)), to study select positions. Results suggest that the N-to-N distance of the tetramer is ~52 nm.

Public Health Relevance

Mutations in mechanosensitive channels cause an array of human diseases, e.g., mutations in Piezo1 causes xerocytosis, which causes red blood cell volume to be dis-regulated (15,24); a K+ channel TRAAK, causes migraines and is the target of many pharmacological agents (52). The bacterial analog, MscL, is comparatively well understood, but basic biophysics, such as the size of the open channel, and mechanism of opening, are not known. We will discover these through smFRET and modeling via Molecular Dynamics. A eukaryotic channel, Piezo1, will also be studied.

Agency
National Institute of Health (NIH)
Institute
National Institute of General Medical Sciences (NIGMS)
Type
Research Project (R01)
Project #
5R01GM108578-02
Application #
8899356
Study Section
Biochemistry and Biophysics of Membranes Study Section (BBM)
Program Officer
Chin, Jean
Project Start
2014-08-01
Project End
2018-07-31
Budget Start
2015-08-01
Budget End
2016-07-31
Support Year
2
Fiscal Year
2015
Total Cost
Indirect Cost
Name
University of Illinois Urbana-Champaign
Department
Physics
Type
Biomed Engr/Col Engr/Engr Sta
DUNS #
041544081
City
Champaign
State
IL
Country
United States
Zip Code
61820
Teng, Kai Wen; Ren, Pin; Selvin, Paul R (2018) Delivery of Fluorescent Probes Using Streptolysin O for Fluorescence Microscopy of Living Cells. Curr Protoc Protein Sci 93:e60
Zhang, Ruobing; Fruhwirth, Gilbert O; Coban, Oana et al. (2017) Probing the Heterogeneity of Protein Kinase Activation in Cells by Super-resolution Microscopy. ACS Nano 11:249-257
Lee, Young Jae; Cintora, Pati; Arikkath, Jyothi et al. (2017) Quantitative assessment of neural outgrowth using spatial light interference microscopy. J Biomed Opt 22:66015
Teng, Kai Wen; Ishitsuka, Yuji; Ren, Pin et al. (2016) Labeling proteins inside living cells using external fluorophores for microscopy. Elife 5:
Wang, Yong; Cai, En; Rosenkranz, Tobias et al. (2014) Small quantum dots conjugated to nanobodies as immunofluorescence probes for nanometric microscopy. Bioconjug Chem 25:2205-11
Wang, Yong; Fruhwirth, Gilbert; Cai, En et al. (2013) 3D super-resolution imaging with blinking quantum dots. Nano Lett 13:5233-41