This proposal will continue the development of a high resolution real time volumetric imaging (RTVI) system. Recent clinical experience with current RTVI supports its strong potential for noninvasive evaluation of the myocardium and cardiac function. Ventricular volumes and mass can be obtained on a beat-to-beat basis without geometric assumptions. RTVI improves accuracy of stress echo for early detection of perfusion deficits, reduces patient examination time, and eliminates pediatric sedation for scanning. Improvements in image quality and field of view are essential in fully exploiting the benefits of RTVI. Significant progress has been made towards the implementation of a 64:1 parallel processed scanner featuring up to 512 individual transmit and receive channels which will lead to improved image quality. Data acquisition rates have been increased by transmitting multiple ultrasound beams from the same aperture in rapid succession. This research could have major importance in overcoming reduced echo sensitivities in RTVI. The project continues on the hypothesis that using 2D arrays, multiple beam transmissions, and receive parallel processing can be effectively implemented to improve the resolution, field of view, dynamic range, and sensitivity of real time volumetric images. This renewal application proposes to complete construction and testing of the novel high resolution real time scanner and compare its performance with current scanners (2D and 3D). It proposes to optimize and implement Duke's unique multi-beam transmission system for 2D arrays. This proposal also aims to develop a unique, very high speed, scan conversion system capable of on line rendering of volumetric data for improved visualization and anatomical identification. To further improve resolution and image quality, this proposal will develop novel specialized IC's near the transducer to permit the use of over 1000 active elements without further increase in cable size. Once this barrier is eliminated, the team will implement the necessary hardware to increase receiver count to over 1000 channels.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
2R01HL058104-04
Application #
6126729
Study Section
Diagnostic Imaging Study Section (DMG)
Project Start
1997-07-01
Project End
2004-06-30
Budget Start
2000-07-01
Budget End
2001-06-30
Support Year
4
Fiscal Year
2000
Total Cost
$477,509
Indirect Cost
Name
Duke University
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
071723621
City
Durham
State
NC
Country
United States
Zip Code
27705
Kuo, Johnny; Bredthauer, Gregory R; Castellucci, John B et al. (2007) Interactive volume rendering of real-time three-dimensional ultrasound images. IEEE Trans Ultrason Ferroelectr Freq Control 54:313-8
Kuo, J; Atkins, B Z; Hutcheson, K A et al. (2005) Left ventricular wall motion analysis using real-time three-dimensional ultrasound. Ultrasound Med Biol 31:203-11
Lacefield, J C; von Ramm, O T (2000) Angular scatter ultrasound imaging of wavelength scale targets. J Acoust Soc Am 108:1914-9
Schmidt, M A; Ohazama, C J; Agyeman, K O et al. (1999) Real-time three-dimensional echocardiography for measurement of left ventricular volumes. Am J Cardiol 84:1434-9
Shiota, T; Jones, M; Chikada, M et al. (1998) Real-time three-dimensional echocardiography for determining right ventricular stroke volume in an animal model of chronic right ventricular volume overload. Circulation 97:1897-900
Morsy, A A; Von Ramm, O T (1998) 3D ultrasound tissue motion tracking using correlation search. Ultrason Imaging 20:151-9