Cardiovascular disease remains the leading cause of death in the United States. Coronary magnetic resonance angiography (MRA) has the potential to become a non-invasive clinical alternative to diagnostic coronary catheterization, with an attendant reduction in both morbidity and cost. We propose that the combination of breath-hold 3D MRA, first-pass contrast enhancement, and partially parallel data acquisition, will provide unprecedented flexibility and robustness for coronary artery MRA, and help to establish it as a clinically useful test.
The specific aims are: 1a) To implement breath-hold 3D MRA so that a volumetric study with a temporal window of 100 msec or less, and 0.5 mm or better in-plane spatial resolution, can be obtained. 1b) To implement the SMASH technique so as to improve temporal or spatial resolution in 3D MRA by a factor of 2-8. 2) To optimize the enhancement of the coronary arteries using contrast agents. To additionally test the feasibility of imaging the entire coronary tree in a single breath-hold using multiplanar, multiangle contrast-enhanced 3D MRA. 3) To evaluate the use of these techniques in a series of patients with documented coronary artery disease. The goal is to optimize the MRA method and to determine if the use of contrast agents provides any clinical benefit.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
1R01HL060708-01A1
Application #
2854261
Study Section
Diagnostic Radiology Study Section (RNM)
Project Start
1999-09-01
Project End
2000-06-30
Budget Start
1999-09-01
Budget End
2000-06-30
Support Year
1
Fiscal Year
1999
Total Cost
Indirect Cost
Name
Beth Israel Deaconess Medical Center
Department
Type
DUNS #
076593722
City
Boston
State
MA
Country
United States
Zip Code
02215
Edelman, Robert R (2004) Contrast-enhanced MR imaging of the heart: overview of the literature. Radiology 232:653-68
Li, Wei; Storey, Pippa; Chen, Qun et al. (2004) Dark flow artifacts with steady-state free precession cine MR technique: causes and implications for cardiac MR imaging. Radiology 230:569-75
Storey, Pippa; Li, Wei; Chen, Qun et al. (2004) Flow artifacts in steady-state free precession cine imaging. Magn Reson Med 51:115-22
Azhari, Haim; Sodickson, Daniel K; Edelman, Robert R (2003) Rapid MR imaging by sensitivity profile indexing and deconvolution reconstruction (SPID). Magn Reson Imaging 21:575-84
Li, Wei; Stern, Jessica S; Mai, Vu M et al. (2002) MR assessment of left ventricular function: quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique. J Magn Reson Imaging 16:559-64
Storey, Pippa; Chen, Qun; Li, Wei et al. (2002) Band artifacts due to bulk motion. Magn Reson Med 48:1028-36
Sodickson, D K; McKenzie, C A; Li, W et al. (2000) Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: A pilot study. Radiology 217:284-9