The objective of this research is to develop free breathing cardiac magnetic resonance imaging for accurate and fast assessment of cardiac morphology, ventricular function, flow dynamics and myocardial characterization. Currently clinical cardiac MRI is performed using the breath-holding 2D acquisition approach, imaging the heart slice by slice through many repetitive breath-holds. The limitations of this breath-hold approach include inapplicability in dyspneic patients, poor image quality with problematic breath-holding, slice misregistration, indequate spatial resolution and volume coverage. The free breathing approach to address these breath-hold problems have been developed by us and others using the pencil beam diaphragm navigator. However, free breathing cardiac MRI is rarely performed in clincal practice, partly because cardiac navigator sequences have not been adequately developed, the diaphragm navigator does not measure heart motion directly, and current navigator scan time is too long. We propose to expand and optimize free breathing navigator cardiac MRI sequences. The cardiac fat navigator will be used to directly monitor motion of the heart. Navigator scan efficiency will be increased using the simultaneous mulitple volume approach. The scan time will be further shortened using multiple coil based parallel imaging. Upon successful completion, this research will lead to a fast and accurate free breathing cardiac MRI. In this five year research project, we will focus on developing navigator parallel imaging for two types of pulse sequences, eletrocardiogram-triggered segmented sequences (black blood fast spin echo and myocardial delayed enhancement) and cine sequences (cine phase contrast, and cine steady state free precession). These are the four most commonly used pulse sequences in our practice. Accordingly we plan to achieve the goal of fast accurate free breathing cardiac MRI through the following specific aims: 1. Develop cardiac fat navigator and integrated navigator parallel imaging for ECG-triggered segmented sequences. 2. Develop navigator parallel imaging for cine sequences. 3. Evaluate developed free breathing cardiac MRI in a cohort of cardiac patients. This research grant will develop fast free breathing cardiac MRI sequences using the navigator method and the accelerated parallel imaging method. It will overcome the limitation of current breath hold cardiac MRI. It will extend the benefit of cardiac MRI examination to patients with difficulty holding breath. It will improve the spatial resolution, spatial coverage, temporal resolution, and scan speed of cardiac MRI.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
3R01HL064647-06S1
Application #
7822225
Study Section
Medical Imaging Study Section (MEDI)
Program Officer
Evans, Frank
Project Start
2009-06-01
Project End
2010-10-31
Budget Start
2009-06-01
Budget End
2010-10-31
Support Year
6
Fiscal Year
2009
Total Cost
$22,835
Indirect Cost
Name
Weill Medical College of Cornell University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
060217502
City
New York
State
NY
Country
United States
Zip Code
10065
Cooper, Mitchell A; Nguyen, Thanh D; Spincemaille, Pascal et al. (2014) How accurate is MOLLI T1 mapping in vivo? Validation by spin echo methods. PLoS One 9:e107327
Liu, Jing; Nguyen, Thanh D; Zhu, Yanchun et al. (2014) Self-gated free-breathing 3D coronary CINE imaging with simultaneous water and fat visualization. PLoS One 9:e89315
Kawaji, Keigo; Spincemaille, Pascal; Nguyen, Thanh D et al. (2014) Direct coronary motion extraction from a 2D fat image navigator for prospectively gated coronary MR angiography. Magn Reson Med 71:599-607
Cooper, Mitchell A; Nguyen, Thanh D; Spincemaille, Pascal et al. (2012) Flip angle profile correction for T? and T? quantification with look-locker inversion recovery 2D steady-state free precession imaging. Magn Reson Med 68:1579-85
Spincemaille, Pascal; Liu, Jing; Nguyen, Thanh et al. (2011) Z intensity-weighted position self-respiratory gating method for free-breathing 3D cardiac CINE imaging. Magn Reson Imaging 29:861-8
Codella, Noel C F; Spincemaille, Pascal; Prince, Martin et al. (2011) A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation. NMR Biomed 24:844-54
Liu, Tian; Khalidov, Ildar; de Rochefort, Ludovic et al. (2011) A novel background field removal method for MRI using projection onto dipole fields (PDF). NMR Biomed 24:1129-36
Liu, Jing; Spincemaille, Pascal; Codella, Noel C F et al. (2010) Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition. Magn Reson Med 63:1230-7
Mendoza, Dorinna D; Codella, Noel C F; Wang, Yi et al. (2010) Impact of diastolic dysfunction severity on global left ventricular volumetric filling - assessment by automated segmentation of routine cine cardiovascular magnetic resonance. J Cardiovasc Magn Reson 12:46
Nguyen, Thanh D; de Rochefort, Ludovic; Spincemaille, Pascal et al. (2008) Effective motion-sensitizing magnetization preparation for black blood magnetic resonance imaging of the heart. J Magn Reson Imaging 28:1092-100

Showing the most recent 10 out of 18 publications