The fundamental goal of the proposed program is to bring to the point of clinical readiness a new electrically powered, totally implantable TAH, based on the Magscrew actuator and the biolized blood pump.
The specific aims to meet this goal are: (1) To design and develop an advanced technology, fail safe, electronic control unit (ECU), which will maintain the patient's life after an electrical failure, until maintenance is performed. The ECU also contains hardware and patient monitoring capability, and a telemetry function. (2) To build and test refined versions of the remaining system components, based on current state of the art technology. (3) To integrate the components into a functional, complete system. (4) To perform in-vivo performance tests, exercising system capabilities. (5) To perform in-vivo durability tests. (6) To perform bench endurance tests. (7) To complete this work in compliance with FDA Design Control Regulations. As a consequence of this design and testing effort, surgeons will have another, superior choice among relatively limited TAH alternatives. The """"""""biolized"""""""" pump of the Magscrew TAH has pericardial valves combined with biological, protein blood contacting surfaces, and a long track record of extremely rare thrombo-embolic episodes in calves, despite the absence of anti-coagulation. In addition, the Magscrew actuator is the conceptually simplest and most rugged of those available for TAH's, with very few contacting or rubbing surfaces. Mechanical failures have very few possible sources, which clearly increases both reliability and long-term durability. The """"""""fail safe"""""""" controller will address the residual pinched wire, corroded solder joint, software hang-up and similar problems that are unavoidable, even with the best fundamental design, and rigorous quality control, in sophisticated, densely packed electronics that are implanted in a hostile environment, and that have caused failures of other, older systems. While the clinical need for TAH's is consistently estimated to be much smaller than for VAD's, it is of a size both nationally and internationally to be of commercial significance. In the United States, it may exceed $1B per year in potential sales. The TAH market will support several suppliers, if not as many as now pursuing the VAD market. To those patients who will need a TAH, the potentially very limited supply of alternatives is of literally life and death significance.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL067628-02
Application #
6527875
Study Section
Special Emphasis Panel (ZRG1-SB (04))
Program Officer
Baldwin, Tim
Project Start
2001-09-26
Project End
2003-07-31
Budget Start
2002-08-01
Budget End
2003-07-31
Support Year
2
Fiscal Year
2002
Total Cost
$1,996,034
Indirect Cost
Name
Cleveland Clinic Lerner
Department
Type
DUNS #
017730458
City
Cleveland
State
OH
Country
United States
Zip Code
44195
Casas, Fernando; Weber, Stephan; Klatte, Ryan et al. (2011) Cycle testing of the MagScrew total artificial heart external battery pack: update I. Artif Organs 35:188-91
Kamohara, Keiji; Weber, Stephan; Klatte, Ryan S et al. (2007) Hemodynamic and metabolic changes during exercise in calves with total artificial hearts of different sizes yet similar output. Artif Organs 31:667-76
Casas, Fernando; Weber, Stephan; Klatte, Ryan et al. (2007) Cycle testing of the MagScrew total artificial heart external battery pack. Artif Organs 31:698-702
Kamohara, Keiji; Weber, Stephan; Klatte, Ryan S et al. (2006) Replacement of the left-side valves of an implanted total artificial heart. ASAIO J 52:368-72
Weber, Stephan; Kamohara, Keiji; Klatte, Ryan S et al. (2005) MagScrew TAH: an update. ASAIO J 51:xxxvi-xlvi
Schenk, Soren; Weber, Stephan; Luangphakdy, Viviane et al. (2005) MagScrew total artificial heart in vivo performance above 200 beats per minute. Ann Thorac Surg 79:1378-83; discussion 1383
Fukamachi, Kiyotaka (2004) New technologies for mechanical circulatory support: current status and future prospects of CorAide and MagScrew technologies. J Artif Organs 7:45-57