For the foreseeable future, bioprosthetic heart valves (BHV) fabricated from xenograft biomaterials will remain the dominant replacement prosthetic valve design. However, BHV durability remains limited to 10-15 years. Failure is usually the result of leaflet tructural deterioration mediated by fatigue and/or tissue mineralization. Thus, independent of valve design specifics (e.g. standard stented valve, percutaneous delivery), the development of novel xenograft biomaterials with improved durability remains an important clinical goal. This represents a unique cardiovascular engineering challenge resulting from the extreme valvular mechanical demands that occur with blood contact. Yet, current BHV assessment relies exclusively on device-level evaluations, which are confounded by simultaneous and highly coupled biomaterial mechanical behaviors and fatigue, valve design, hemodynamics, and calcification. Thus, despite decades of clinical BHV usage and growing popularity, there exists no acceptable method for assessing and simulating BHV durability at the component biomaterial level. This situation has contributed to the current stagnation in BHV biomaterial development, limiting rationally developed improvements in BHV durability. We hypothesize that a biomechanically rigorous and physiologically realistic in-vivo approach can be developed for a mechanistic understanding of intrinsic BHV biomaterial performance. Once developed, such an approach can be used to rationally design novel biomaterials that significantly improve BHV durability. While calcification prevention has not been completely solved, ethanol post-treatment has been shown to strongly reduce its onset. Moreover, others and we have shown that tissue degeneration is a major independent mechanism underlying BHV limited durability both in-vitro and in-vivo. Thus, our focus will be on mechanisms of early tissue degeneration and means to reduce damage accumulation, leading to improving BHV durability.

Public Health Relevance

By developing a biomechanically and biologically realistic in vivo approach unique to develop novel biomaterials for heart valve bioprostheses, coupled to comprehensive simulations, we will develop more durable biomaterials for high stress valvular replacement consistently engineered for improved BHV durability.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL108330-02
Application #
8461138
Study Section
Bioengineering, Technology and Surgical Sciences Study Section (BTSS)
Program Officer
Lundberg, Martha
Project Start
2012-04-20
Project End
2016-02-29
Budget Start
2013-03-01
Budget End
2014-02-28
Support Year
2
Fiscal Year
2013
Total Cost
$552,221
Indirect Cost
$77,847
Name
University of Texas Austin
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
170230239
City
Austin
State
TX
Country
United States
Zip Code
78712
Tam, H; Zhang, W; Infante, D et al. (2017) Fixation of Bovine Pericardium-Based Tissue Biomaterial with Irreversible Chemistry Improves Biochemical and Biomechanical Properties. J Cardiovasc Transl Res 10:194-205
Rego, Bruno V; Sacks, Michael S (2017) A functionally graded material model for the transmural stress distribution of the aortic valve leaflet. J Biomech 54:88-95
Zhang, Will; Sacks, Michael S (2017) Modeling the response of exogenously crosslinked tissue to cyclic loading: The effects of permanent set. J Mech Behav Biomed Mater 75:336-350
Lee, Chung-Hao; Zhang, Will; Feaver, Kristen et al. (2017) On the in vivo function of the mitral heart valve leaflet: insights into tissue-interstitial cell biomechanical coupling. Biomech Model Mechanobiol 16:1613-1632
Kamensky, David; Hsu, Ming-Chen; Yu, Yue et al. (2017) Immersogeometric cardiovascular fluid-structure interaction analysis with divergence-conforming B-splines. Comput Methods Appl Mech Eng 314:408-472
Soares, João S; Zhang, Will; Sacks, Michael S (2017) A mathematical model for the determination of forming tissue moduli in needled-nonwoven scaffolds. Acta Biomater 51:220-236
Goth, Will; Lesicko, John; Sacks, Michael S et al. (2016) Optical-Based Analysis of Soft Tissue Structures. Annu Rev Biomed Eng 18:357-85
Soares, Joao S; Feaver, Kristen R; Zhang, Will et al. (2016) Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance. Cardiovasc Eng Technol 7:309-351
Goth, Will; Yang, Bin; Lesicko, John et al. (2016) POLARIZED SPATIAL FREQUENCY DOMAIN IMAGING OF HEART VALVE FIBER STRUCTURE. Proc SPIE Int Soc Opt Eng 9710:
Aggarwal, Ankush; Pouch, Alison M; Lai, Eric et al. (2016) In-vivo heterogeneous functional and residual strains in human aortic valve leaflets. J Biomech 49:2481-90

Showing the most recent 10 out of 32 publications