Positron Emission Tomography Imaging of Thrombus. The goal of this proposal is to develop a fibrin-specific positron emission tomography (PET) probe for direct imaging of thrombus. Thrombus is implicated in a range of pathologies, e.g. ischemic stroke, myocardial infarction, pulmonary embolism, and deep vein thrombosis. The presence of thrombus changes treatment decisions and imaging is widely used rule in, or out, the presence of thrombus. Despite the different imaging methods available, there is still a strong unmet medical need for direct identification of thrombus. For instance, identification of the source of the embolus in ischemic stroke is critical to patient management, but currently 30- 40% of strokes are of unknown origin. This proposed PET probe may enable identification of stroke source and identify patients who would benefit from more aggressive antithrombotic therapy to prevent secondary stroke. Stroke is the third leading cause of death and the leading cause of morbidity in the US. According to the American Stroke Association, Americans will pay almost $69 billion dollars this year in stroke related medical costs and disability. An imaging tool to identify those at risk for secondary stroke may be expected to positively impact morbidity and mortality associated with stroke. The thrombus probe is based on a peptide that binds to and has specificity for fibrin over circulating fibrinogen or other plasma proteins. Fibrin is present in acute and sub-chronic venous and arterial thrombi in high concentrations, but fibrin is not present in circulating blood. A selective fibrin imaging probe is expected to provide high sensitivity and specificity for thrombus identification. While PET offers molecular specificity, it suffers from low spatial resolution and lacks anatomical landmarks. Hybrid PET - computed tomography (CT) or PET - magnetic resonance imaging (MRI) devices are now available that enable co-registration of the molecular PET image to the vascular anatomical images obtained by CT or MRI. This proposal builds on positive preliminary PET-MRI thrombus imaging data with a prototype PET probe.
In Aim 1 we focus on synthesizing a series of fluorine-18 and copper-64 labeled peptides to optimize the imaging properties of thrombus-targeted PET probe.
In Aim 2 we will characterize these new probes with respect to their affinity to the fibrin target, their specificity for fibrin over other plasma proteins, and their metabolic stability in the presence of plasma or liver homogenate.
In Aim 3 we explore the efficacy of these probes in fresh and aged thrombus models in rats and rabbits using PET-CT and PET-MRI. Dosimetry estimates will be performed on optimized probes and the most promising will be evaluated for acute toxicity. The output of this research will be a novel thrombus imaging probe that may be subsequently developed for human use.

Public Health Relevance

Thrombosis (blood clot) is implicated in a number of diseases such as stroke, heart attack, and pulmonary embolism. This goal of this project is to identify a positron emitting imaging probe and imaging methodology to noninvasively and directly detect thrombus.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
1R01HL109448-01
Application #
8160555
Study Section
Clinical Molecular Imaging and Probe Development (CMIP)
Program Officer
Link, Rebecca P
Project Start
2011-08-01
Project End
2015-07-31
Budget Start
2011-08-01
Budget End
2012-07-31
Support Year
1
Fiscal Year
2011
Total Cost
$601,700
Indirect Cost
Name
Massachusetts General Hospital
Department
Type
DUNS #
073130411
City
Boston
State
MA
Country
United States
Zip Code
02199
Boros, Eszter; Pinkhasov, Omar R; Caravan, Peter (2018) Metabolite profiling with HPLC-ICP-MS as a tool for in vivo characterization of imaging probes. EJNMMI Radiopharm Chem 3:2
Shea, Barry S; Probst, Clemens K; Brazee, Patricia L et al. (2017) Uncoupling of the profibrotic and hemostatic effects of thrombin in lung fibrosis. JCI Insight 2:
Oliveira, Bruno L; Caravan, Peter (2017) Peptide-based fibrin-targeting probes for thrombus imaging. Dalton Trans 46:14488-14508
Blasi, Francesco; Oliveira, Bruno L; Rietz, Tyson A et al. (2015) Multisite Thrombus Imaging and Fibrin Content Estimation With a Single Whole-Body PET Scan in Rats. Arterioscler Thromb Vasc Biol 35:2114-21
Blasi, Francesco; Oliveira, Bruno L; Rietz, Tyson A et al. (2015) Radiation Dosimetry of the Fibrin-Binding Probe ??Cu-FBP8 and Its Feasibility for PET Imaging of Deep Vein Thrombosis and Pulmonary Embolism in Rats. J Nucl Med 56:1088-93
Oliveira, Bruno L; Blasi, Francesco; Rietz, Tyson A et al. (2015) Multimodal Molecular Imaging Reveals High Target Uptake and Specificity of 111In- and 68Ga-Labeled Fibrin-Binding Probes for Thrombus Detection in Rats. J Nucl Med 56:1587-92
Loving, Galen S; Caravan, Peter (2014) Activation and retention: a magnetic resonance probe for the detection of acute thrombosis. Angew Chem Int Ed Engl 53:1140-3
Ay, Ilknur; Blasi, Francesco; Rietz, Tyson A et al. (2014) In vivo molecular imaging of thrombosis and thrombolysis using a fibrin-binding positron emission tomographic probe. Circ Cardiovasc Imaging 7:697-705
Boros, Eszter; Rybak-Akimova, Elena; Holland, Jason P et al. (2014) Pycup--a bifunctional, cage-like ligand for (64)Cu radiolabeling. Mol Pharm 11:617-29
Blasi, Francesco; Oliveira, Bruno L; Rietz, Tyson A et al. (2014) Effect of Chelate Type and Radioisotope on the Imaging Efficacy of 4 Fibrin-Specific PET Probes. J Nucl Med 55:1157-63

Showing the most recent 10 out of 14 publications