Valvular heart disease is an important health problem afflicting over 2.5% of the US population and, while surgical repair of native tissue remains the gold standard, the reduced risk of catheter-based interventions has provided the capability to intervene earlier in the disease process as well as in the sickest patients while avoiding the risk of cardiopulmonary bypass and also enabling intra-operative assessment of the repair. The outcomes of transcatheter procedures, however, remain inferior to surgery. For example, in transcatheter aortic valve replacement (TAVR), moderate to severe paravalvular leaks are a significant problem and have been shown to decrease short-term survival. As a second example, those patients receiving transcatheter edge-to-edge repair of mitral regurgitation required follow-up surgery for recurrent mitral regurgitation substantially more often than those undergoing initial surgical repair. Optimal patient care would combine the benefits of beating-heart interventions with the effectiveness of surgical repair. We hypothesize that the fundamental limitation toward meeting this goal is the ability of the clinician to manipulate tissu at the time of device implantation to optimize device function. In contrast to optically-guided open surgery, catheter-based delivery greatly reduces the interventionalist's capability to visualize and precisely manipulate tissue. To address these limitations, we propose to develop a transapical two-arm robotic catheter platform with integrated cardioscopic imaging for beating-heart valve repair. The use of two coordinated arms will enable tissue manipulation comparable to surgery in which one hand positions tissue and the other hand interacts with it. Cardioscopic imaging in the catheter tip(s) will provide high-fidelity optical imaging of catheter-tissue contac for safe and precise tissue interaction. The transapical approach enables substantially shorter and more controllable instruments while robotic control provides precise steerability for two-handed tissue manipulation inside the beating heart as well as the potential for computer-based force control. We will evaluate the effectiveness of the proposed technology against current clinical practice in the context of two important problems, transcatheter aortic PVL closure and mitral edge-to-edge repair, using ex vivo and in vivo animal experiments. The overall impact of the project extends to all beating-heart valve procedures.

Public Health Relevance

Valvular heart disease affects over 2.5% of the US population. While catheter-based valve interventions substantially decrease patient risk in comparison to open surgery, they are less effective since existing catheters and imaging technologies cannot replicate the dexterity and visualization afforded by open surgery. To enable more effective and complex beating-heart procedures, we propose to develop a two-handed robotic catheter system with integrated endoscopic imaging.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL124020-03
Application #
9110350
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Lee, Albert
Project Start
2014-07-22
Project End
2018-06-30
Budget Start
2016-07-01
Budget End
2017-06-30
Support Year
3
Fiscal Year
2016
Total Cost
Indirect Cost
Name
Children's Hospital Boston
Department
Type
DUNS #
076593722
City
Boston
State
MA
Country
United States
Zip Code
Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E (2018) Varying ultrasound power level to distinguish surgical instruments and tissue. Med Biol Eng Comput 56:453-467
Ha, Junhyoung; Dupont, Pierre E (2017) Designing Stable Concentric Tube Robots Using Piecewise Straight Tubes. IEEE Robot Autom Lett 2:298-304
Rosa, Benoit; Machaidze, Zurab; Shin, Borami et al. (2017) A low-cost bioprosthetic semilunar valve for research, disease modelling and surgical training applications. Interact Cardiovasc Thorac Surg 25:785-792
Ha, Junhyoung; Park, Frank C; Dupont, Pierre E (2017) Optimizing Tube Precurvature to Enhance Elastic Stability of Concentric Tube Robots. IEEE Trans Robot 33:22-37
Rosa, Benoit; Machaidze, Zurab; Mencattelli, Margherita et al. (2017) Cardioscopically Guided Beating Heart Surgery: Paravalvular Leak Repair. Ann Thorac Surg 104:1074-1079
Ha, Junhyoung; Park, Frank C; Dupont, Pierre E (2016) Elastic Stability of Concentric Tube Robots Subject to External Loads. IEEE Trans Biomed Eng 63:1116-28
Ataollahi, Asghar; Berra, Ignacio; Vasilyev, Nikolay V et al. (2016) Cardioscopic Tool-delivery Instrument for Beating-heart Surgery. IEEE ASME Trans Mechatron 21:584-590
Fagogenis, Georgios; Bergeles, Christos; Dupont, Pierre E (2016) Adaptive Nonparametric Kinematic Modeling of Concentric Tube Robots. Rep U S 2016:4324-4329
Jang, Cheongjae; Ha, Junhyoung; Dupont, Pierre E et al. (2016) Toward On-line Parameter Estimation of Concentric Tube Robots Using a Mechanics-based Kinematic Model. Rep U S 2016:2400-2405
Manjila, Sunil; Mencattelli, Margherita; Rosa, Benoit et al. (2016) A multiport MR-compatible neuroendoscope: spanning the gap between rigid and flexible scopes. Neurosurg Focus 41:E13

Showing the most recent 10 out of 13 publications