The objective of this project is to develop a new method, adaptive functional magnetic resonance imaging (MR), to enable the precise spatial localization of human brain function. The intended application of this method is the preoperative planning and intraoperative guidance of neurosurgical interventions. The clinical significance of this work is that it will create a new instrument to minimize post-operative functional deficits for surgical patients. The hypothesis is that dynamically adaptive MRI can perform whole-brain functional mapping at 1.5mm isotropic resolution while still maintaining clinically practical imaging times of less than 15 minutes.
The specific aims to test this hypothesis are: (1) To develop imaging sequences that are both suitable for functional MRI and compatible with the requirements of dynamically adaptive MRI; (2) To develop real-time protocols to enable the necessary computer-scanner interaction to meet the requirements of dynamically adaptive imaging; (3) To develop software for real-time processing and display of fMRI data in a dynamically adaptive environment; (4) To develop algorithms for dynamically adaptive MRI based on a multi-resolution zooming approach; (5) To optimize the multi-resolution adaptive fMRI method and to evaluate performance with respect to conventional fMRI; and (6) To apply dynamically adaptive fMRI for neurosurgical planning and, to evaluate it with respect to its precision and accuracy for localizing function. Real-time adaptive imaging is a methodology that modifies the image acquisition strategy """"""""on-line"""""""" as an examination proceeds in order to tailor it to each individual brain and then zoom-in on local sites of activation. The long-term goal of this project is to fully develop this methodology in order to provide the surgeon with a versatile and powerful technological tool (comprising new methods, hardware and software) to enhance the planning, guiding and monitoring of neurosurgical interventions.

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Research Project (R01)
Project #
5R01NS037922-03
Application #
6531084
Study Section
Special Emphasis Panel (ZRG1-DMG (04))
Program Officer
Pancrazio, Joseph J
Project Start
2000-04-07
Project End
2004-02-29
Budget Start
2002-03-01
Budget End
2004-02-29
Support Year
3
Fiscal Year
2002
Total Cost
$336,778
Indirect Cost
Name
Brigham and Women's Hospital
Department
Type
DUNS #
071723621
City
Boston
State
MA
Country
United States
Zip Code
02115
Chou, Y-h; Panych, L P; Dickey, C C et al. (2012) Investigation of long-term reproducibility of intrinsic connectivity network mapping: a resting-state fMRI study. AJNR Am J Neuroradiol 33:833-8
Rolls, Hillary K; Yoo, Seung-Schik; Zou, Kelly H et al. (2007) Rater-dependent accuracy in predicting the spatial location of functional centers on anatomical MR images. Clin Neurol Neurosurg 109:225-35
Chen, Nan-kuei; Oshio, Koichi; Panych, Lawrence P (2006) Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI. Neuroimage 31:609-22
Zhao, Lei; Madore, Bruno; Panych, Lawrence P (2005) Reduced field-of-view MRI with two-dimensional spatially-selective RF excitation and UNFOLD. Magn Reson Med 53:1118-25
Ou, Wanmei; Golland, Polina (2005) From spatial regularization to anatomical priors in fMRI analysis. Inf Process Med Imaging 19:88-100
Wei, Xingchang; Yoo, Seung-Schik; Dickey, Chandlee C et al. (2004) Functional MRI of auditory verbal working memory: long-term reproducibility analysis. Neuroimage 21:1000-8
Chen, Nan-Kuei; Dickey, Chandlee C; Yoo, Seung-Schik et al. (2003) Selection of voxel size and slice orientation for fMRI in the presence of susceptibility field gradients: application to imaging of the amygdala. Neuroimage 19:817-25
Chen, Nan-kuei; Egorova, Svetlana; Guttmann, Charles R G et al. (2003) Functional MRI with variable echo time acquisition. Neuroimage 20:2062-70
Panych, L P; Zhao, L; Jolesz, F A et al. (2001) Dynamic imaging with multiple resolutions along phase-encode and slice-select dimensions. Magn Reson Med 45:940-7