During development of the nervous system the response of growing axons to their environment is critical to the formation of the complex wiring pattern between neurons. Growth and guidance factors combined with extracellular matrices influence the speed and direction of axonal growth. Although much progress has been made in identifying the factors that influence axonal growth, as well as how axons respond to these factors individually, much less is known about how axons behave in response to the combined effects of multiple factors. As a complementary approach to present in vivo molecular imaging approaches, we propose to develop an in vitro environment that potentially mimics some of the complexity found in vivo, in particular the development of the anterior visual pathway. In this system, the axon trajectories are simple, multiple relevant guidance molecules have been identified already (many tested with explants in vitro), and a common cause of blindness (Optic Nerve Hypoplasia) is associated with defects in this process. Additionally, the patterns of guidance molecules found on the flat anatomy of the retina are ideally suited to mimicking by micropatterning and microfluidics techniques. This mimicry will be accomplished by combining microfluidics patterning of diffusible gradients and laser patterning of substrate-bound axon pathfinding cues, including axon guidance factors and extracellular matrix molecules. As a source of highly homogeneous cell populations, we will isolate mouse retinal ganglion cells (RGCs), a cell type that responds to Netrin-1 gradients. For experiments designed to maximize the integrity of the cells (isolation procedures are damaging to cells), we will use retinal explants and we will microfluidically isolate the axons from their somas. RGCs (or their axons) will be exposed to various soluble factors that have previously been shown to affect their axon growth in vivo. The new microfluidic systems will allow us to test the combinatorial effects of multiple factors on the direction and speed of axonal growth of RGCs. These experiments will allow us to quantitatively examine the basic principles that govern axon pathfinding in the development of the anterior visual pathway. This information will help to better understand the basis of developmental defects in axon growth that alter the organization and function of the nervous system.

Public Health Relevance

The study of axon guidance has been limited to a single signal gradient. In vivo, neurons encounter multiple signals (both bound to substrate and in solution) and must make choices in an information rich environment. The proposed study will probe axon guidance interactions of unprecedented complexity as well as with unprecedented measurement precision, which will significantly further our understanding of axon growth on a cellular and molecular level, neural development as a whole, and may provide insight on treating neurological disorders, nerve regeneration, and vascular pathologies.

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Research Project (R01)
Project #
1R01NS064387-01A2
Application #
8109748
Study Section
Neurotechnology Study Section (NT)
Program Officer
Riddle, Robert D
Project Start
2011-06-15
Project End
2016-05-31
Budget Start
2011-06-15
Budget End
2012-05-31
Support Year
1
Fiscal Year
2011
Total Cost
$341,834
Indirect Cost
Name
University of Washington
Department
Biomedical Engineering
Type
Schools of Engineering
DUNS #
605799469
City
Seattle
State
WA
Country
United States
Zip Code
98195
Balaji, Vidhya; Castro, Kurt; Folch, Albert (2018) A Laser-Engraving Technique for Portable Micropneumatic Oscillators. Micromachines (Basel) 9:
Bhattacharjee, Nirveek; Parra-Cabrera, Cesar; Kim, Yong Tae et al. (2018) Desktop-Stereolithography 3D-Printing of a Poly(dimethylsiloxane)-Based Material with Sylgard-184 Properties. Adv Mater 30:e1800001
Bhattacharjee, N; Horowitz, L F; Folch, A (2016) Continuous-flow multi-pulse electroporation at low DC voltages by microfluidic flipping of the voltage space topology. Appl Phys Lett 109:163702
Urrios, Arturo; Parra-Cabrera, Cesar; Bhattacharjee, Nirveek et al. (2016) 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip 16:2287-94
Bhattacharjee, Nirveek; Urrios, Arturo; Kang, Shawn et al. (2016) The upcoming 3D-printing revolution in microfluidics. Lab Chip 16:1720-42
Au, Anthony K; Bhattacharjee, Nirveek; Horowitz, Lisa F et al. (2015) 3D-printed microfluidic automation. Lab Chip 15:1934-41
Sip, Christopher G; Bhattacharjee, Nirveek; Folch, Albert (2014) Microfluidic transwell inserts for generation of tissue culture-friendly gradients in well plates. Lab Chip 14:302-14
Au, Anthony K; Lee, Wonjae; Folch, Albert (2014) Mail-order microfluidics: evaluation of stereolithography for the production of microfluidic devices. Lab Chip 14:1294-301
Moyes, Kara White; Sip, Christopher G; Obenza, Willimark et al. (2013) Human embryonic stem cell-derived cardiomyocytes migrate in response to gradients of fibronectin and Wnt5a. Stem Cells Dev 22:2315-25
Sip, Christopher G; Bhattacharjee, Nirveek; Folch, Albert (2011) A modular cell culture device for generating arrays of gradients using stacked microfluidic flows. Biomicrofluidics 5:22210

Showing the most recent 10 out of 13 publications