The study of neuronal activity in awake, freely moving animals is the most representative view of 'normal'neuronal function. Anesthetics and restraint have profound effects on neuronal physiology and the correlate animal behavior. The study of real time neuronal event processing requires recording methods with high temporal bandwidth (>500 hz) and the ability to detect physiologically relevant events (i.e. voltage changes). Currently only microelectrode recording of single neuronal units, multiunit activity and field potentials have sufficient temporal resolution and portability to allow recording of neuronal activity in freely moving animals. The proposed project will produce three miniature microscope/imaging systems which can be head-mounted and will allow the optical recording of changes in membrane voltage of neurons in freely moving rats. During the funded two-year ARRA project, two prototype devices and two image sensors were developed that collect wide field image sequences of fluorescent voltage dye signals. The current application will complete the fabrication and operationalize two different style, head-mountable, high-speed, fluorescence microscopes. This includes the design and fabrication of two different finalized, imaging sensors, custom optics for each, a stabilized illumination source and form fit microscope bodies with skull mounts. The studies proposed herein will also build and test a novel fluorescence microscope design that will reduce the height of the traditional microscope by eliminating the 45? dichroic mirror. We will also miniaturize our current camera control and recording system to be fully contained in a back pack on the rat. This back pack will contain a field programmable gate array, heat exchanger/coolant pump, SD memory and a battery to run the microscope fully autonomously. Finally, the instruments will be tested in imaging studies of the rat somatosensory cortex (barrel cortex). Cortical responses to object discrimination will be studied in freely moving rats. These studies will systematically engineer each component to maximize excitation light delivery, fluorescent light collection and recording speed while minimizing weight volume, energy usage and heat generation. The device will be capable of recording rapid (1000 fps) fluorescent image sequences of a >2 mm2 area of cortex and detect small changes in ?F/F (0.1%). The device will be small (<1 cm2 head mounted) and light weight enough (5 g) to be mounted on the head of a freely moving rat. The device is intended as a precursor to devices that can translate neuronal activity in humans into actions in real time, optical brain machine prosthetic.

Public Health Relevance

This project will develop a device to study brain function in awake, behaving mammals. The device represents the first step in the development of a neuroprosthetic device to capture information from neuronal tissue containing intended functional output. Such a device can ultimately be used to allow direct brain control of robotics, computers and instrumentation to allow paralyzed patients a way to exert conscience control of their environment.

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Research Project (R01)
Project #
5R01NS065110-05
Application #
8722632
Study Section
Enabling Bioanalytical and Imaging Technologies Study Section (EBIT)
Program Officer
Ludwig, Kip A
Project Start
2009-08-01
Project End
2016-07-31
Budget Start
2014-08-01
Budget End
2015-07-31
Support Year
5
Fiscal Year
2014
Total Cost
Indirect Cost
Name
John B. Pierce Laboratory, Inc.
Department
Type
DUNS #
City
New Haven
State
CT
Country
United States
Zip Code
06519
Dundar, Aysegul; Jin, Jonghoon; Martini, Berin et al. (2017) Embedded Streaming Deep Neural Networks Accelerator With Applications. IEEE Trans Neural Netw Learn Syst 28:1572-1583
Barbera, Giovanni; Liang, Bo; Zhang, Lifeng et al. (2016) Spatially Compact Neural Clusters in the Dorsal Striatum Encode Locomotion Relevant Information. Neuron 92:202-213
Han, Zhou; Jin, Lei; Chen, Fuyi et al. (2014) Mechanistic studies of the genetically encoded fluorescent protein voltage probe ArcLight. PLoS One 9:e113873
Sparks, John S; Schelly, Robert C; Smith, W Leo et al. (2014) The covert world of fish biofluorescence: a phylogenetically widespread and phenotypically variable phenomenon. PLoS One 9:e83259
Han, Zhou; Jin, Lei; Platisa, Jelena et al. (2013) Fluorescent protein voltage probes derived from ArcLight that respond to membrane voltage changes with fast kinetics. PLoS One 8:e81295
Tang, Wei; Osman, Ahmad; Kim, Dongsoo et al. (2013) Continuous Time Level Crossing Sampling ADC for Bio-Potential Recording Systems. IEEE Trans Circuits Syst I Regul Pap 60:1407-1418
Osman, Ahmad; Park, Joon Hyuk; Dickensheets, David et al. (2012) Design constraints for mobile, high-speed fluorescence brain imaging in awake animals. IEEE Trans Biomed Circuits Syst 6:446-53
Jin, Lei; Han, Zhou; Platisa, Jelena et al. (2012) Single action potentials and subthreshold electrical events imaged in neurons with a fluorescent protein voltage probe. Neuron 75:779-85
Barnett, Lauren; Platisa, Jelena; Popovic, Marko et al. (2012) A fluorescent, genetically-encoded voltage probe capable of resolving action potentials. PLoS One 7:e43454
Baker, Bradley J; Jin, Lei; Han, Zhou et al. (2012) Genetically encoded fluorescent voltage sensors using the voltage-sensing domain of Nematostella and Danio phosphatases exhibit fast kinetics. J Neurosci Methods 208:190-6

Showing the most recent 10 out of 11 publications