Recently a new paradigm for doing infrared (IR) spectroscopy was developed in the Principal Investigator's (Pl's) laboratory. PA-IR uses a focal plane array (FPA) detector onto which a beam of light dispersed by a prism or grating is focused. The broad range of frequencies displayed on the pixel array simultaneously make this a multiplex technique without using the complex scanning mechanism or computational requirements (for Fourier transformation of the data) used in FT-IR interferometry. Thus the no-moving parts configuration of the PA-IR instrument provides the ruggedness required to make the instrument the size of a """"""""shoe-box"""""""" and hence portable. In addition the increased sensitivity (100-1000X over single element FT-IR detectors) of the FPA can provide an IR spectrum to be accumulated in as little as 10 microseconds. The only current limitation comes from the frequency range available (3400-2000 cm[-1]) due to the initial availability of only indium-antimonide FPAs during the development of the prototype. This proposal is to design and construct a portable """"""""broad band"""""""" PA-IR instrument that works in the more traditional IR """"""""fingerprint"""""""" region (2000-800 cm [-1]) now that Mercury-Cadmium-Telluride FPAs are commercially available and show that it has the sensitivity and speed for in vivo disease prediction/diagnosis. If the PA-IR instrument is coupled with an IR fiber optic sampling probe, it should be possible to characterize ocular tissues in the lens. The advantage of this fiber optic PA-IR technique over conventional dynamic light scattering (DLS) systems currently in use for eye diagnostics is that PA-IR will provide a chemical signature of the various components (collagen IV, gamma-crystallin, etc.) present simultaneously in the """"""""real-time"""""""" domain potentially allowing both qualitative and quantitative analysis of the components. For example, PA-IR would allow the detection of protein aggregation (dimers, oligomers) and be able to detect changes in the amount of alpha-helical, beta-sheet or disordered conformation in a protein thereby detecting the onset of cataracts at a very early stage before protein particles become large enough to be detected by DLS. Once this """"""""broad Band"""""""" PA-IR is shown to have high sensitivity then other applications such as monitoring the presence of airborne bacteria and viruses in hospital environments becomes feasible as well.
Kim, Young Shin; Chase, Bruce; Kiick, Kristi L et al. (2010) Molecular rearrangement of metal-chelating lipid monolayers upon protein adsorption. Langmuir 26:336-43 |
Kim, Young Shin; Snively, Christopher M; Liu, Yujuan et al. (2008) Real-time imaging of crystallization in polylactide enantiomeric monolayers at the air-water interface. Langmuir 24:10791-6 |
Kim, Young Shin; Snively, Christopher M; Rabolt, John F et al. (2007) Development of a planar array infrared reflection spectrograph for reflection-absorption spectroscopy of thin films at metal and water surfaces. Appl Spectrosc 61:916-20 |