This application proposes to investigate the diagnostic precision for detecting glaucoma of clinical electrophysiological measurement (pattern electroretinogram, PERG; and multifocal visual evoked potentials, mfVEP), a technique identified as an important recent glaucoma- related development in eye research by the 2004 National Eye Institute (NEI) National Plan.
Aim 1 : Electrophysiological responses will be characterized in glaucoma, suspect and healthy eyes and the diagnostic accuracy of these commercially available techniques will be compared to current reference standards (evaluation of stereoscopic photographs of the optic disc and standard automated perimetry) and to recently developed diagnostic techniques including optical imaging of the optic disc and retinal nerve fiber layer (RNFL) (confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry) and visual function-specific perimetry (short-wavelength automated perimetry and frequency doubling technology perimetry).
Aim 2 : Novel use of machine learning classifier techniques (e.g. relevance vector machines, support vector machines, mixture of Gaussian techniques, independent components analysis) will be applied to electrophysiological data to improve its diagnostic accuracy and data from different diagnostic techniques (named above) will be combined to improve overall diagnostic accuracy.
Aim 3 : Electrophysiological measurements will be validated as functional indicators of optic nerve damage by examining the relationship between electrophysiological abnormality and optic disc and RNFL damage in glaucoma and glaucoma suspect patients. 210 patients (105 glaucoma's, 105 glaucoma suspects) and 105 healthy participants will be enrolled and studied cross-sectionally.
The specific aims of this proposal address the current NEI Glaucoma and Optic Neuropathies Program objectives of developing improved diagnostic measures to characterize and detect optic nerve disease onset, determining functional correlates of optic nerve damage, and characterizing glaucomatous neurodegeneration within the visual pathways at structural and functional levels. Information about the relative usefulness of electrophysiological measurement, optical imaging techniques, and ganglion cell-specific perimetry for glaucoma detection is important to the clinical community for determining future evidence-based changes in standard of care for glaucoma diagnosis and monitoring. These studies will demonstrate the relative usefulness of electrophysiological measurement (pattern electroretinogram, PERG; multi-focal visual evoked potential, mfVEP) compared to optical imaging techniques (confocal scanning ophthalmoscopy, optical coherence tomography, scanning laser polarimetry) and ganglion cell-specific perimetry (short wavelength and frequency doubling perimetry) for glaucoma detection. The proposal addresses the current NEI Glaucoma and Optic Neuropathies Program objectives of developing improved diagnostic measures to characterize and detect optic nerve disease onset, determining functional correlates of optic nerve damage, and characterizing glaucomatous neurodegeneration within the visual pathways at structural and functional levels. Findings will be important to the clinical community for determining future evidence-based changes in standard of care for glaucoma diagnosis and monitoring. ? ? ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Exploratory/Developmental Grants (R21)
Project #
1R21EY018190-01
Application #
7242398
Study Section
Special Emphasis Panel (ZRG1-BDCN-F (12))
Program Officer
Liberman, Ellen S
Project Start
2007-07-01
Project End
2009-06-30
Budget Start
2007-07-01
Budget End
2008-06-30
Support Year
1
Fiscal Year
2007
Total Cost
$218,125
Indirect Cost
Name
University of California San Diego
Department
Ophthalmology
Type
Schools of Medicine
DUNS #
804355790
City
La Jolla
State
CA
Country
United States
Zip Code
92093
Bowd, C; Tafreshi, A; Zangwill, L M et al. (2011) Pattern electroretinogram association with spectral domain-OCT structural measurements in glaucoma. Eye (Lond) 25:224-32
Tafreshi, Ali; Racette, Lyne; Weinreb, Robert N et al. (2010) Pattern electroretinogram and psychophysical tests of visual function for discriminating between healthy and glaucoma eyes. Am J Ophthalmol 149:488-95
Vizzeri, Gianmarco; Tafreshi, Ali; Weinreb, Robert N et al. (2010) Effect of operator and optical defocus on the variability of pattern electroretinogram optimized for glaucoma detection (PERGLA). J Glaucoma 19:77-82
Bowd, Christopher; Tafreshi, Ali; Vizzeri, Gianmarco et al. (2009) Repeatability of pattern electroretinogram measurements using a new paradigm optimized for glaucoma detection. J Glaucoma 18:437-42
Bowd, Christopher; Vizzeri, Gianmarco; Tafreshi, Ali et al. (2009) Diagnostic accuracy of pattern electroretinogram optimized for glaucoma detection. Ophthalmology 116:437-43
Vizzeri, Gianmarco; Balasubramanian, Madhusudhanan; Bowd, Christopher et al. (2009) Spectral domain-optical coherence tomography to detect localized retinal nerve fiber layer defects in glaucomatous eyes. Opt Express 17:4004-18