This project aims to develop and test two innovative platforms and related software for 3-D imaging flow cytometry of fluorescent or absorbing (stained) samples. These systems will allow 3-D structural and functional imaging of many single cells at a subcellular resolution and at a scale that used to be available only in flow cytometry or recently in 2-D imaging. Thereby, the proposed methods have the potential to fundamentally change the ways cultured cells, patient-derived samples, and small experimental organisms are studied. Automated classification based on the 3-D features will enable the diagnosis of hematologic disorders at single-cell precision. Existing 3-D microscopy methods can provide the same information at higher resolution; however, by relying on a scanning mechanism they cannot be applied to suspending cells, especially in a flow configuration, which is essential for high-speed interrogation. Snapshot 3-D microscopy techniques have been developed to address this challenge, but they have insufficient spatial resolution for single-cell imaging and suffer from long data processing time. We overcome these limitations by combining two novel snapshot techniques developed by the PI with the most rigorous optical imaging theories and cutting-edge component technologies. We will use an array of lenslets, which simultaneously records many projection images corresponding with different viewing angles. The use of pupil phase masks, designed using wavefront coding and a theory of 3-D high-numerical-aperture optical imaging, will increase the resolution of each projection image to the theoretical limit given by the objective-lens numerical aperture. The target resolution is 0.5 m, which is comparable to existing 2-D imaging flow cytometry systems. The target imaging throughputs based on current component technologies are 120 volumes/sec for fluorescence imaging and 700 volumes/sec for absorption imaging, which are higher than 100 volumes/sec of cutting-edge 3-D optical microscopy for stationary specimens. The vast amount of data acquired by these 3-D imaging systems imposes a serious challenge to data processing. The developed systems record true projection images, which obviate iterative deconvolution process, thereby allowing much faster tomographic reconstruction than in existing snapshot techniques. Using general-purpose graphics processing units and optical diffraction tomography, which includes the diffraction of light by subcellular organelles, our tomographic reconstruction algorithm will be faster yet more accurate than existing approaches. Further, we will explore the feasibility of applying a deep convolutional neural network to the images acquired by the developed systems for accurate single-cell classification based on 3-D features.

Public Health Relevance

This project aims to develop 3-D imaging flow cytometry platforms for fluorescent or absorbing (stained) cells at high resolution and high throughput in a flow configuration. The developed systems will be built upon two novel snapshot 3-D techniques developed by the PI in combination with most rigorous 3-D optical imaging theories and cutting-edge component technologies. The proposed methods have the potential to fundamentally change the ways that biological specimens are examined by allowing 3-D structural and functional imaging of suspending cells at a scale that used to be available only in flow cytometry or 2-D imaging.

Agency
National Institute of Health (NIH)
Institute
National Institute of General Medical Sciences (NIGMS)
Type
Exploratory/Developmental Grants (R21)
Project #
5R21GM135848-02
Application #
10023268
Study Section
Instrumentation and Systems Development Study Section (ISD)
Program Officer
Sammak, Paul J
Project Start
2019-09-24
Project End
2021-06-30
Budget Start
2020-07-01
Budget End
2021-06-30
Support Year
2
Fiscal Year
2020
Total Cost
Indirect Cost
Name
University of Wisconsin Milwaukee
Department
Engineering (All Types)
Type
Biomed Engr/Col Engr/Engr Sta
DUNS #
627906399
City
Milwaukee
State
WI
Country
United States
Zip Code
53201