The primary objective of this research is to develop new technology to characterize personal exposure to airborne metals in the workplace. The secondary objective is to improve upon the state-of-the-art in both sensitivity and time-resolution of airborne metals exposure assessment. Key to this effort is an innovative technology called microfluidic paper analytical devices (?PADs) that integrate sampling with analysis in a low cost, high sensitivity format. Our central hypothesis is that ?PADs can be integrated into personal aerosol samplers for quantification of personal exposure to airborne metals with sampling and analysis times of less than one hour. To test this hypothesis, we propose the following specific aims: (1) Construct a single-analyte microfluidic paper analytical device (?PAD) for metal analysis that is compatible with existing, size-selective personal aerosol samplers;(2) Construct a multi-analyte ?PAD for analysis of Pb, Cu, Mn, and Ni concentrations in air;(3) Validate the performance of the multi-analyte ?PAD in the field. Successful completion of the above aims will provide industrial hygienists with a sensitive, in-situ technique to assess airborne metal hazards in the workplace. Such technology represents a paradigm shift in the field of exposure assessment, as it has the potential to replace the traditional practice of sample shipment and laboratory analysis (both of which are time and resource intensive) with a direct, field analysis technique with improved sensitivity and time-resolution. This research contributes to the National Occupational Research Agenda (NORA) by developing a new and inexpensive instrumentation (a cross-sector theme) for assessing worker exposure (a cross-sector theme) to airborne metals (affecting the transportation/utilities, manufacturing, and construction sectors). Chemical analysis of a ?PAD sample is expected to be at least an order of magnitude less expensive (around 5$ per sample) than analysis with traditional ICP-MS or AES techniques. Furthermore, integrating the ?PAD into existing aerosol sampling devices (i.e., inhalable filter samplers) will enhance its acceptance by practicing occupational health professionals. This technology may open the door to a new realm of aerosol exposure assessment, as ?PADs can be adapted to detect and quantify many metal, organic, or inorganic compounds.

Public Health Relevance

The primary purpose of exposure assessment is to identify and prevent workplace conditions likely to cause injury and disease. Exposure assessment methods rely on the ability to make quantitative measurements of health hazards with little or no uncertainty, an assumption that is lacking for many emerging respiratory hazards in the workplace (e.g., beryllium, cadmium, and engineered nanoparticles). The sampling technology proposed here (?PAD) will help reduce this uncertainty by providing industrial hygienists with detection limits low enough to make informed decisions on protecting worker health and by aiding occupational epidemiologists in the detection of respiratory diseases without a proportionate increase in exposure assessment costs.

Agency
National Institute of Health (NIH)
Institute
National Institute for Occupational Safety and Health (NIOSH)
Type
Exploratory/Developmental Grants (R21)
Project #
5R21OH010050-02
Application #
8326458
Study Section
Safety and Occupational Health Study Section (SOH)
Program Officer
Frederick, Linda J
Project Start
2011-07-01
Project End
2014-06-30
Budget Start
2012-07-01
Budget End
2014-06-30
Support Year
2
Fiscal Year
2012
Total Cost
$231,906
Indirect Cost
$68,145
Name
Colorado State University-Fort Collins
Department
Public Health & Prev Medicine
Type
Schools of Veterinary Medicine
DUNS #
785979618
City
Fort Collins
State
CO
Country
United States
Zip Code
80523
Ruecha, Nipapan; Rodthongkum, Nadnudda; Cate, David M et al. (2015) Sensitive electrochemical sensor using a graphene-polyaniline nanocomposite for simultaneous detection of Zn(II), Cd(II), and Pb(II). Anal Chim Acta 874:40-8
Cate, David M; Adkins, Jaclyn A; Mettakoonpitak, Jaruwan et al. (2015) Recent developments in paper-based microfluidic devices. Anal Chem 87:19-41
Cate, David M; Noblitt, Scott D; Volckens, John et al. (2015) Multiplexed paper analytical device for quantification of metals using distance-based detection. Lab Chip 15:2808-18
Cate, David M; Nanthasurasak, Pavisara; Riwkulkajorn, Pornpak et al. (2014) Rapid detection of transition metals in welding fumes using paper-based analytical devices. Ann Occup Hyg 58:413-23
Rattanarat, Poomrat; Dungchai, Wijitar; Cate, David et al. (2014) Multilayer paper-based device for colorimetric and electrochemical quantification of metals. Anal Chem 86:3555-62
Cate, David M; Dungchai, Wijitar; Cunningham, Josephine C et al. (2013) Simple, distance-based measurement for paper analytical devices. Lab Chip 13:2397-404
Dungchai, Wijitar; Sameenoi, Yupaporn; Chailapakul, Orawon et al. (2013) Determination of aerosol oxidative activity using silver nanoparticle aggregation on paper-based analytical devices. Analyst 138:6766-73
Rattanarat, Poomrat; Dungchai, Wijitar; Cate, David M et al. (2013) A microfluidic paper-based analytical device for rapid quantification of particulate chromium. Anal Chim Acta 800:50-5
Mentele, Mallory M; Cunningham, Josephine; Koehler, Kirsten et al. (2012) Microfluidic paper-based analytical device for particulate metals. Anal Chem 84:4474-80
Ratnarathorn, Nalin; Chailapakul, Orawon; Henry, Charles S et al. (2012) Simple silver nanoparticle colorimetric sensing for copper by paper-based devices. Talanta 99:552-7