) While adenocarcinoma of the prostate is the most commonly diagnosed cancer in American men and the second leading cause of cancer mortality, technologic and engineering advances have not pushed diagnosis or treatment methods forward when compared to, for example, brain cancers. The objective of this research and development project is to create a methodology suitable for spatially accurate image-guided diagnosis and treatment of prostate cancer. Our method is based around the newly emerging techniques in interventional MRI (IMRI) and nuclear imaging, including image registration, image guided biopsy, and direct monitoring of thermal therapy. To test our methodology, we will perform careful validation testing in an experimental animal model to justify future clinical trials and clinical evaluation in patients. Specifically, we will acquire MRI volume scans of the pelvis and register these images with nuclear scans that provide metabolic/monoclonal indicators of disease. This first registration will semi-automatically combine image data sets with markedly different spatial, contrast and SNR characteristics. During guidance to the prostate lesion, we will compare new rapid MRI techniques with improved immunity to motion to existing methods, and we will complete development and validation of two methods for IMRI navigation where the target tissue and the interventional device are ensured to remain in the scan plane. Two methods shown to be feasible for IMRl guided procedures will be integrated with registered data sets to provide both scan planes which always include the interventional tool and the target tissue and a best estimate of the registered data at the same orientation to improve accuracy of placement of the tools into the most appropriate tissue location. Guidance accuracy will be validated. Image registration methods during guidance will provide accurate automated multi-modality resolution between the new rapidly acquired data and previously registered nuclear and MRI data as a method to improve targeted biopsy and treatment. We will develop new methods to visualize information, like the interventional tool trajectory and tissue temperature and validate their accuracy. We will use phantoms when possible, but more importantly, we will create a canine model to provide comparable tissue deformation, perfusion, morphology and organ and physiologic motion expected in human trials. Finally, we will validate accuracy of both our image guided biopsy and image guided minimally invasive treatment under realistic conditions.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Exploratory/Developmental Grants Phase II (R33)
Project #
1R33CA088144-01
Application #
6196934
Study Section
Special Emphasis Panel (ZCA1-SRRB-Y (M1))
Program Officer
Farahani, Keyvan
Project Start
2000-09-14
Project End
2003-06-30
Budget Start
2000-09-14
Budget End
2001-08-31
Support Year
1
Fiscal Year
2000
Total Cost
$269,102
Indirect Cost
Name
Case Western Reserve University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
077758407
City
Cleveland
State
OH
Country
United States
Zip Code
44106
Frericks, B B; Elgort, D R; Hillenbrand, C et al. (2009) Magnetic resonance imaging-guided renal artery stent placement in a Swine model: comparison of two tracking techniques. Acta Radiol 50:21-7
Wacker, Frank K; Vogt, Sebastian; Khamene, Ali et al. (2006) An augmented reality system for MR image-guided needle biopsy: initial results in a swine model. Radiology 238:497-504
Hillenbrand, Claudia M; Jesberger, John A; Wong, Eddy Y et al. (2006) Toward rapid high resolution in vivo intravascular MRI: evaluation of vessel wall conspicuity in a porcine model using multiple imaging protocols. J Magn Reson Imaging 23:135-44
Moriguchi, Hisamoto; Duerk, Jeffrey L (2006) Bunched phase encoding (BPE): a new fast data acquisition method in MRI. Magn Reson Med 55:633-48
Wacker, Frank K; Hillenbrand, Claudia; Elgort, Daniel R et al. (2005) MR imaging-guided percutaneous angioplasty and stent placement in a swine model comparison of open- and closed-bore scanners. Acad Radiol 12:1085-8
Maes, Robbert M; Lewin, Jonathan S; Duerk, Jeffrey L et al. (2005) Combined use of the intravascular blood-pool agent, gadomer, and carbon dioxide: a novel type of double-contrast magnetic resonance angiography (MRA). J Magn Reson Imaging 21:645-9
Lee, Zhenghong; Sodee, D Bruce; Resnick, Martin et al. (2005) Multimodal and three-dimensional imaging of prostate cancer. Comput Med Imaging Graph 29:477-86
Fei, Baowei; Duerk, Jeffrey L; Sodee, D Bruce et al. (2005) Semiautomatic nonrigid registration for the prostate and pelvic MR volumes. Acad Radiol 12:815-24
Hwang, Ken-Pin; Flask, Chris; Lewin, Jonathan S et al. (2004) Selective missing pulse steady state free precession (MP-SSFP): inner volume and chemical shift selective imaging in a steady state sequence. J Magn Reson Imaging 19:124-32
Wacker, Frank K; Nour, Sherif G; Eisenberg, Rosana et al. (2004) MRI-guided radiofrequency thermal ablation of normal lung tissue: in vivo study in a rabbit model. AJR Am J Roentgenol 183:599-603

Showing the most recent 10 out of 37 publications