The long term goal of this project is to develop a novel cone beam volume computed tomography breast imaging (CBVCTBI) technique to provide clinically useful three-dimensional (3D) high resolution tomographic images for breast cancer detection. CBVCTBI will require only a single fast volume scanning (4.8-9.6 seconds) to provide true 3D description of breast anatomy with 2.0-5.0 1p/mm isotropic resolution and will provide adequate low contrast resolution and high contrast spatial resolution for breast cancer detection.The clinical significance of CBVCTBI is that it will improve the sensitivity of breast cancer detection due to its much better low contrast resolution, compared to conventional mammography. CBVCTBI with high resolution volume of interest (VOI) reconstruction mode for target imaging, will also better characterize breast tumors three-dimensionally; conventional mammography does not provide 3D information of breast cancer. CBVCTBI will be developed and validated through computer simulation, phantom and specimen studies performed on a specially designed DBVCTBI prototype system that uses a flat panel detector (FPD) and cone beam tomographic acquisition geometry. This is an R21-R33 combined project.
Specific aims of the R21project include: 1) Perform phantom studies to determine the required total exposure level (absorbed patient dose) for breast cancer imaging task, 2) Implement and optimize a fast cone beam reconstruction algorithm on a dual processor PC workstation, 3) Perform a comparison study of breast coverage near the chest wall between a conventional mammography system and a slightly modified standard stereotactic biopsy table (which will be used for the prototype CBVCTBI scanner) to provide evidence for appropriate coverage of the breast near the chest wall. 4) Obtain institutional review boar (IRB) approval to image breast specimens in the R33 project period.
Specific aims for the R33 project period include: 1) Estimate glandular radiation dose for CBVCTBI technique, 2) Implement and optimize the cone beam reconstruction algorithms based on the different new volume scan schemes, 3) Develop the FPD-based prototype system, 4) Evaluate the prototype system, 5) Perform phantom and specimen studies to validate the CBVCTBI technique and optimize the system performance.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Exploratory/Developmental Grants Phase II (R33)
Project #
5R33CA094300-04
Application #
7082212
Study Section
Special Emphasis Panel (ZCA1-SRRB-9 (O1))
Program Officer
Farahani, Keyvan
Project Start
2003-06-03
Project End
2009-05-31
Budget Start
2006-07-26
Budget End
2009-05-31
Support Year
4
Fiscal Year
2006
Total Cost
$585,662
Indirect Cost
Name
University of Rochester
Department
Radiation-Diagnostic/Oncology
Type
Schools of Dentistry
DUNS #
041294109
City
Rochester
State
NY
Country
United States
Zip Code
14627
Cai, Weixing; Zhao, Binghui; Conover, David et al. (2012) Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model. Med Phys 39:543-53
Yu, Yang; Ning, Ruola; Cai, Weixing (2011) Performance Evaluation of a Differential Phase-contrast Cone-beam (DPC-CBCT) System for Soft Tissue Imaging. Proc SPIE Int Soc Opt Eng 7961:79614X
Cai, Weixing; Ning, Ruola; Conover, David (2011) Scatter correction for clinical cone beam CT breast imaging based on breast phantom studies. J Xray Sci Technol 19:91-109
O'Connell, Avice; Conover, David L; Zhang, Yan et al. (2010) Cone-beam CT for breast imaging: Radiation dose, breast coverage, and image quality. AJR Am J Roentgenol 195:496-509
Benitez, Ricardo Betancourt; Ning, Ruola; Conover, David et al. (2009) Measurements of the modulation transfer function, normalized noise power spectrum and detective quantum efficiency for two flat panel detectors: a fluoroscopic and a cone beam computer tomography flat panel detectors. J Xray Sci Technol 17:279-93
Benitez, Ricardo Betancourt; Ning, Ruola; Conover, David et al. (2009) NPS characterization and evaluation of a cone beam CT breast imaging system. J Xray Sci Technol 17:17-40
Zhang, Xiaohua; Ning, Ruola; Yang, Dong (2009) Cone Beam Breast CT noise reduction using 3D adaptive Gaussian filtering. J Xray Sci Technol 17:319-33
Chen, Zikuan; Ning, Ruola (2006) Volume fusion for two-circular-orbit cone-beam tomography. Appl Opt 45:5960-6