? The OLINDA/EXM code, which replaces the popular MIRDOSE code for calculating dose estimates in nuclear medicine applications, was given an exemption by the FDA on June 15, 2004 to be distributed as a medical device. The code will have a 3 year lifetime, and may be considered for re-release in June of 2007. The current code contains the traditional phantom types (Cristy/Eckerman), which are considered state-of-the-art in internal dosimetry today, but which many believe should be replaced with more realistic phantom types, as is being made possible by advanced medical imaging technologies and other approaches. More realistic representations of organ geometries and overlap provide better estimates of organ doses for use in diagnostic and therapeutic applications of radiopharmaceuticals in medicine, particularly in cancer therapy. The use of voxel-based Magnetic Resonance Imaging (MRI), Computed Tomography (CT), Single Photon Computed Tomography (SPECT) and Positron Emission Tomography (PET) imaging systems provide 3D representations of patient anatomy. Preliminary data comparing dose calculations from existing standard stylized (MIRD) models and those based on real human images have demonstrated some notable differences in calculated absorbed fractions and dose factors. Two standardized phantoms, one each representing the adult male and female, have been developed under the direction of the International Commission on Radiological Protection, and phantoms representing the newborn and pregnant woman at 7 months' gestation have also been designed. We propose extension of these works to develop a complete phantom library is needed to provide the user community with a full set of realistic phantoms for routine use in nuclear medicine. Other, more general radiation safety applications as well will benefit from these more realistic phantoms. Phase I of this project will entail review and testing of existing work, identification of specific phantoms necessary to complete the OLINDA/EXM library and gathering of candidate image data sets for segmentation. Phase II will entail the segmentation of the phantoms, modification of the phantoms to meet organ mass requirements, calculation of dose conversion factors for all organs, using Monte Carlo techniques, and implementation of results into the OLINDA/EXM code. ? ?

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Small Business Technology Transfer (STTR) Grants - Phase II (R42)
Project #
1R42CA115122-01
Application #
6935596
Study Section
Special Emphasis Panel (ZRG1-SBMI (10))
Program Officer
Baker, Houston
Project Start
2005-05-01
Project End
2006-04-30
Budget Start
2005-05-01
Budget End
2006-04-30
Support Year
1
Fiscal Year
2005
Total Cost
$107,000
Indirect Cost
Name
Radar, Inc.
Department
Type
DUNS #
156779378
City
Nashville
State
TN
Country
United States
Zip Code
37221
Xu, X George (2014) An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history. Phys Med Biol 59:R233-302
Stabin, Michael G; Xu, X George; Emmons, Mary A et al. (2012) RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry. J Nucl Med 53:1807-13
Stabin, M G; Emmons, M A; Segars, W P et al. (2012) Realistic reference adult and paediatric phantom series for internal and external dosimetry. Radiat Prot Dosimetry 149:56-9
Clark, Landon D; Stabin, Michael G; Fernald, Michael J et al. (2010) Changes in radiation dose with variations in human anatomy: moderately and severely obese adults. J Nucl Med 51:929-32
Guo, Bingqi; Xu, X George; Shi, Chengyu (2010) Specific absorbed fractions for internal electron emitters derived for a set of anatomically realistic reference pregnant female models. Radiat Prot Dosimetry 138:20-8
Marine, Patrick M; Stabin, Michael G; Fernald, Michael J et al. (2010) Changes in radiation dose with variations in human anatomy: larger and smaller normal-stature adults. J Nucl Med 51:806-11
Keenan, Mary A; Stabin, Michael G; Segars, William P et al. (2010) RADAR realistic animal model series for dose assessment. J Nucl Med 51:471-6
Shi, C Y; Xu, X George; Stabin, Michael G (2008) SAF values for internal photon emitters calculated for the RPI-P pregnant-female models using Monte Carlo methods. Med Phys 35:3215-24
Xu, X George; Taranenko, Valery; Zhang, Juying et al. (2007) A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods--RPI-P3, -P6 and -P9. Phys Med Biol 52:7023-44
Zaidi, Habib; Xu, Xie George (2007) Computational anthropomorphic models of the human anatomy: the path to realistic Monte Carlo modeling in radiological sciences. Annu Rev Biomed Eng 9:471-500