In 2015, 1,658,370 new cancer cases are estimated to occur in the US, where nearly two-thirds will have radiation therapy (RT). Given that there are over 2,300 RT centers in the US, and current systems for contouring organs at risk (OARs) rely mostly on manual methods, there is a strong commercial opportunity for producing a software system that can contour OARs in medical images at a high degree of automation and for impacting current practice of RT planning. Encouraged by our strong Phase I results in thoracic and head and neck (H&N) body regions compared to current industry systems, we seek the accuracy, efficiency, and clinical acceptance of the contours output by our software product to significantly exceed those of existing systems. Our overall aim for Phase II is to advance the algorithms and prototype software developed in Phase I into a leading commercial software product, and demonstrate its efficacy in multiple medical centers across the country with diverse populations. Phase II specific aims are three-fold: (1) Further advance the automatic anatomy recognition algorithms from Phase I using advanced deep learning techniques. (2) Develop a cloud-based software auto contouring service. (3) Perform clinical evaluation of the new software on H&N and thoracic cases.
Aim 1 will be accomplished in three stages: (a) Automating the process of defining the body region on given patient CT studies, which is currently done manually in our system, via a new concept of virtual landmarks using deep learning techniques. (b) Improving object recognition/ localization accuracy from the current 2 voxels for ?good? quality data sets to 1 voxel and from 4-5 voxels for ?poor? quality data sets to 2-3 voxels by using virtual landmarks to learn object relationships. (c) Improving object delineation by combining object localization methods with deep learning techniques applied to the vicinity of the localized objects to bring boundary distance accuracy within 1 voxel.
Aim 2 will be achieved by developing a cloud-based Software-as-a-Service model to implement the software that incorporates the algorithms. To accomplish Aim 3, an evaluation study involving four academic RT centers will be undertaken to assess the efficiency, accuracy, and acceptability of the contours output by the new software. To assess efficiency, contouring time taken by the current clinical process will be compared to the time taken by the new software method plus any manual adjustment needed. Accuracy will be assessed by comparing software output to carefully prepared ground truth contours. Acceptability will be determined by conducting a blinded reader study, where an acceptability score (1-5) is given by radiation oncologists to software produced contours, ground truth contours, and contours produced by the normal clinical process, and comparing these scores. Expected clinical outcomes are significantly improved clinical efficiency/ acceptability of contouring compared to current practice.

Public Health Relevance

There is a strong commercial opportunity for producing a software system that can contour organs at risk in medical images at a high degree of automation for impacting current practice of radiation therapy planning. Encouraged by strong competitive results from the Phase I part of this project, in this grant, further technical advances and a cloud-based software service are proposed. A multicenter clinical evaluation of the new product is also planned to assess the clinical efficacy of the system.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Small Business Technology Transfer (STTR) Grants - Phase II (R42)
Project #
3R42CA199735-03S1
Application #
10241562
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Zhao, Ming
Project Start
2016-06-10
Project End
2021-07-31
Budget Start
2020-09-01
Budget End
2021-07-31
Support Year
3
Fiscal Year
2020
Total Cost
Indirect Cost
Name
Quantitative Radiology Solutions, LLC
Department
Type
DUNS #
079089213
City
Philadelphia
State
PA
Country
United States
Zip Code
19104