Active Tuberculosis (TB) causes approximately 2 million annual deaths. An estimated 9.3 million people worldwide develop TB every year, of which 4.4 million are undiagnosed. When diagnosed properly, most TB cases can be treated. Currently, sputum expectorate is the most common sampling method used for TB diagnosis. Sputum is difficult to collect from some patients (children and elderly), and is unattainable from ex- pectoration deficient patients ( 20% of patients). Sputum is also contaminated by oropharyngeal flora, saliva, mucus, and cell debris which negatively affects the sensitivity and specificity of diagnostics, and lowers their impact on treatment decisions. Deton's device avoids all the disadvantages of sputum samples by collecting air- borne bacteria directly from cough aerosol for subsequent diagnosis. All patients can produce cough;therefore, samples can be collected from the entire patient population, including patients who cannot expectorate sputum. Furthermore, the cough collection concentrates bacteria in a small sample volume of buffer that supports the viability of fragile organisms;whereas, sputum concentration (fixed number of cells per mL) and medium cannot be altered. Finally, the collected cough droplet material is potentially free of the various oropharyngeal contaminants in sputum. The Phase I aims of the proposed work are:
Aim 1 : Investigate whether collected cough samples result in higher diagnostic sensitivity and specificity than sputum samples.
Aim 2 : Improve the device geometry to maximize collection efficiency and machine the new design for lab and clinical evaluations. Phase I aims will enable the testing of the device for different lung infections such as non-tuberculosis mycobacterial infections and community acquired pneumonia in Phase II. Furthermore, a more patient-friendly disposable device can be manufactured based on the second prototype and the patient data.

Public Health Relevance

Among infectious diseases, active tuberculosis (TB) is the second leading cause of death worldwide ( 2 million/year) with 9.3 million people worldwide developing TB every year. Most current TB diagnostic methods rely on sputum samples and suffer from the its disadvantages such as oral flora contamination and inability of some patients to produce sputum. The proposed work studies the feasibility of replacing sputum samples by collecting cough droplets from patients using a novel device.

Agency
National Institute of Health (NIH)
Institute
National Institute of Allergy and Infectious Diseases (NIAID)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43AI102418-01
Application #
8393515
Study Section
Special Emphasis Panel (ZRG1-IDM-V (12))
Program Officer
Jacobs, Gail G
Project Start
2012-06-15
Project End
2014-05-31
Budget Start
2012-06-15
Budget End
2013-05-31
Support Year
1
Fiscal Year
2012
Total Cost
$300,000
Indirect Cost
Name
Deton Corporation
Department
Type
DUNS #
830844523
City
Pasadena
State
CA
Country
United States
Zip Code
91107