The long-term goal of this project is to develop an intelligent prosthetic foot that reduces the energy consumption of walking in amputees. Commercial prostheses use passive mechanisms to provide articulation, cushioning against heel impact, and elastic energy return; yet the energetic cost of amputee walking is high. Currently the most sophisticated prostheses are intelligent knees, which improve gait by actively controlling braking of the knee. Based on recent laboratory results, we propose that controlled energy storage and release could significantly improve the efficiency of a prosthetic foot. Such a foot would store elastic energy after the foot strikes the ground, as in current products. But instead of returning energy spontaneously, active control would capture that energy with a latch mechanism, and release it later in the gait cycle, coinciding with the push-off phase of able-bodied walking. The proposed mechanism will be microprocessor-controlled, and will require battery power mainly to actuate a latch rather than to actively power gait. This low power demand means that the prosthesis will be able to operate for hours at a time using lightweight batteries. Phase II of this project will develop a prototype prosthesis, and experimentally test the conceptual feasibility of intelligently controlled energy release. We intend to develop this concept into a commercial prosthesis with greater energy return and comfort than conventional designs, in a compact and lightweight package. The proposed research has three Specific Aims: design and fabrication, testing on able-bodied subjects, and testing on transtibial (below-knee) amputees. (1.) The design component consists of developing a lightweight and compact, computer-controlled mechanism for controlling and then returning mechanical energy to the user. (2.) We will test the device on able-bodied subjects, to compare the metabolic energy that they expend during walking. Able-bodied subjects will be used to monitor the differences between the prototype device, conventional prostheses, and able-bodied walking. (3.) We will also test the device on the target population of transtibial amputees. We will provide subjects with long-term loans of the prototype device so that they can practice walking and become familiar with it. We will then compare their energy demand when walking on their own prosthesis, with a high performance conventional prosthesis, and with the prototype device. We will test whether controlled energy storage reduces the metabolic demand for walking, which serves as an objective measure of the device's efficacy. Relevance: This research addresses the public health problem of reduced mobility in lower-limb amputees using prosthetic feet. These amputees walk at lower speed, high energy cost, and with lower range and comfort than able-bodied individuals. The proposed controlled energy storage prosthetic foot is intended to provide measurable improvements in these aspects of mobility. This project seeks to reduce the energetic demand of walking in lower limb amputees, for whom walking with a prosthesis is more fatiguing than for able-bodied persons. The project will develop a prosthetic foot with an ability to efficiently store energy that is normally dissipated in conventional prostheses, and then to return that energy to power walking, in order to reduce the effort of walking for amputees. ? ?

Agency
National Institute of Health (NIH)
Institute
Eunice Kennedy Shriver National Institute of Child Health & Human Development (NICHD)
Type
Small Business Innovation Research Grants (SBIR) - Phase II (R44)
Project #
2R44HD055706-02
Application #
7273030
Study Section
Musculoskeletal Rehabilitation Sciences Study Section (MRS)
Program Officer
Quatrano, Louis A
Project Start
2007-09-28
Project End
2009-08-31
Budget Start
2007-09-28
Budget End
2008-08-31
Support Year
2
Fiscal Year
2007
Total Cost
$374,999
Indirect Cost
Name
Intelligent Prosthetic Systems, LLC
Department
Type
DUNS #
126621767
City
Ann Arbor
State
MI
Country
United States
Zip Code
48104
Zelik, Karl E; Huang, Tzu-Wei P; Adamczyk, Peter G et al. (2014) The role of series ankle elasticity in bipedal walking. J Theor Biol 346:75-85
Adamczyk, Peter G; Kuo, Arthur D (2013) Mechanical and energetic consequences of rolling foot shape in human walking. J Exp Biol 216:2722-31
Segal, Ava D; Zelik, Karl E; Klute, Glenn K et al. (2012) The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation. Hum Mov Sci 31:918-31
Zelik, Karl E; Kuo, Arthur D (2012) Mechanical work as an indirect measure of subjective costs influencing human movement. PLoS One 7:e31143
Zelik, Karl E; Collins, Steven H; Adamczyk, Peter G et al. (2011) Systematic variation of prosthetic foot spring affects center-of-mass mechanics and metabolic cost during walking. IEEE Trans Neural Syst Rehabil Eng 19:411-9
Snaterse, Mark; Ton, Robert; Kuo, Arthur D et al. (2011) Distinct fast and slow processes contribute to the selection of preferred step frequency during human walking. J Appl Physiol (1985) 110:1682-90
Kuo, Arthur D; Donelan, J Maxwell (2010) Dynamic principles of gait and their clinical implications. Phys Ther 90:157-74
Zelik, Karl E; Kuo, Arthur D (2010) Human walking isn't all hard work: evidence of soft tissue contributions to energy dissipation and return. J Exp Biol 213:4257-64
Kuo, Arthur D; Donelan, J Maxwell (2009) Comment on ""Contributions of the individual ankle plantar flexors to support, forward progression and swing initiation during walking"" ((Neptune et al., 2001) and ""Muscle mechanical work requirements during normal walking: the energetic cost of raising J Biomech 42:1783-5; author reply 1786-9
Gordon, Keith E; Ferris, Daniel P; Kuo, Arthur D (2009) Metabolic and mechanical energy costs of reducing vertical center of mass movement during gait. Arch Phys Med Rehabil 90:136-44

Showing the most recent 10 out of 14 publications