With an increased risk of terrorist attacks involving chemical weapons, including nerve agents, there is a need to develop new and improved countermeasures for the rapid detection of exposure. Hence, this project will develop a portable micro-analytical system for the rapid evaluation of exposure to organophosphorus (OP) nerve agents utilizing phosphorylated cholinesterase (ChE) as a biomarker (OP-ChE adducts) in blood and saliva. Our hypothesis is that a highly selective, ultra sensitive, and disposable biosensor can be developed to detect sub-clinical exposure to nerve agents by using nanoparticle linked antibodies and metal chelation to selectively capture OP-ChE biomarkers followed by electrochemical detection. This project is directly responsive to RFA-NS-06-004 concerning CounterACT research projects (U01) for the development of new diagnostic techniques and tools to enhance our medical response capabilities during an emergency. The approach will involve initial development of an immuno-capture electrochemical detector for OP-ChE biomarkers and the subsequent development of a disposable immunochromatographic electrochemical biosensor (IEB). Diisopropylphosphorofluoridate (DFP) and Sarin will be used as the chemical nerve agents in in vitro and in vivo exposures to generate OP-ChE protein biomarkers in the plasma, RBC, and saliva of rats and humans. OP-ChE biomarkers will be detected with the microfluidic IEB using an approach similar to the ELISA assay, except that primary recognition is performed by nanoparticle-tagged antibodies and secondary recognition is performed by zirconium oxide (ZrO2) chelation with the phosphorylated moiety, followed by detection that is based on generating metal ions by dissolving the nanoparticle and detecting the metal ions upon accumulation to an electrode. The development of a real-time biomonitoring IEB device for analysis of blood and/or saliva represents a significant advancement over current biomonitoring strategies for nerve agent exposure. The utilization of minimally invasive biomatrices, coupled with on-site and rapid detection represents a novel approach with broad application for evaluating deliberate or accidental exposures to chemical nerve agents. ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Research Project--Cooperative Agreements (U01)
Project #
1U01NS058161-01
Application #
7224666
Study Section
Special Emphasis Panel (ZNS1-SRB-R (22))
Program Officer
Jett, David A
Project Start
2006-09-30
Project End
2011-05-31
Budget Start
2006-09-30
Budget End
2007-05-31
Support Year
1
Fiscal Year
2006
Total Cost
$622,608
Indirect Cost
Name
Battelle Pacific Northwest Laboratories
Department
Type
DUNS #
032987476
City
Richland
State
WA
Country
United States
Zip Code
99352
Song, Yang; Luo, Yanan; Zhu, Chengzhou et al. (2016) Recent advances in electrochemical biosensors based on graphene two-dimensional nanomaterials. Biosens Bioelectron 76:195-212
Xu, Wentao; Cheng, Nan; Huang, Kunlun et al. (2016) Accurate and easy-to-use assessment of contiguous DNA methylation sites based on proportion competitive quantitative-PCR and lateral flow nucleic acid biosensor. Biosens Bioelectron 80:654-660
Zhu, Chengzhou; Yang, Guohai; Li, He et al. (2015) Electrochemical sensors and biosensors based on nanomaterials and nanostructures. Anal Chem 87:230-49
Yang, Guohai; Zhu, Chengzhou; Du, Dan et al. (2015) Graphene-like two-dimensional layered nanomaterials: applications in biosensors and nanomedicine. Nanoscale 7:14217-31
Bhattacharya, Priyanka; Du, Dan; Lin, Yuehe (2014) Bioinspired nanoscale materials for biomedical and energy applications. J R Soc Interface 11:20131067
Wang, Hua; Li, Shuai; Si, Yanmei et al. (2014) Platinum nanocatalysts loaded on graphene oxide-dispersed carbon nanotubes with greatly enhanced peroxidase-like catalysis and electrocatalysis activities. Nanoscale 6:8107-16
Zhao, Yuting; Zhang, Weiying; Lin, Yuehe et al. (2013) The vital function of Fe3O4@Au nanocomposites for hydrolase biosensor design and its application in detection of methyl parathion. Nanoscale 5:1121-6
Zhang, Weiying; Ge, Xiaoxiao; Tang, Yong et al. (2013) Nanoparticle-based immunochromatographic test strip with fluorescent detector for quantification of phosphorylated acetylcholinesterase: an exposure biomarker of organophosphorus agents. Analyst 138:5431-6
Zhang, Xiao; Wang, Hongbo; Yang, Chunming et al. (2013) Preparation, characterization of Fe3O4 at TiO2 magnetic nanoparticles and their application for immunoassay of biomarker of exposure to organophosphorus pesticides. Biosens Bioelectron 41:669-74
Zhang, Lin; Zhang, Aidong; Du, Dan et al. (2012) Biosensor based on Prussian blue nanocubes/reduced graphene oxide nanocomposite for detection of organophosphorus pesticides. Nanoscale 4:4674-9

Showing the most recent 10 out of 40 publications