During 2004-2005, research in AMRI was focused on 2 main projects: 1) the investigation of brain activity patterns during rest and sleep; and 2) the development of MRI techniques on NIH's new 7.0 T human scanner. The investigation of brain activity fluctuations during rest was a continuation of earlier research in AMRI. In the previous year, it was found that in absence of external stimuli, brain blood flow fluctuates in most brain regions. This occurs not only during awake rest, but continues during sleep. To reliably measure the cognitive state of subjects and detect sleep, a method was developed to simultaneously measure BOLD fMRI and EEG signals in the 3.0 T scanner. It was found that blood flow fluctuations occur in both awake resting conditions and stage 1 and stage 2 sleep. This suggest that these fluctuations are not caused by active cognitive processes. To establish that the blood flow fluctuations are not simply a vascular phenomenon without a neuronal component, an MRI method was developed to monitor oxygen consumption changes by simultaneously measuring perfusion and blood oxygen level using BOLD MRI. It was found that the fluctuations during sleep are caused by a metabolic process. The development of the 7.0 T human scanner involved both the optimization of signal detectors as well as development of image acquisition techniques. To optimized signal detectors, computer simulations were performed to study the interaction of electro-magnetic fields with brain tissue. Based on this, and in collaboration with Nova Medical Inc, 8 and 16-channel detectors were designed and developed. Initial measurement with these detectors show a 2-4 fold sensitivity improvement compared to conventional coil designs. These detectors are expected to greatly boost the utility of the 7.0 T system. Furthermore, the simulations and measurements suggest that even higher gains in sensitivity can be obtained with 24 or 32-channel detectors. Based on this, we have ordered addtional receiver channels for the 7.0 T system. The development of acquisition techniques has focused on the suppression of image artifacts related to magnetic susceptibility effects and magnetic field fluctuations caused by respiratory-cycle related chest motion. To reduce susceptibility artifacts, image acquisition speed was improved by using accelerated parallel imaging, which is based on the use of the spatially varying detector sensitivity information in the image acquisition process. This has led to a 2-3 fold reduction in artifact level. To reduce artifacts related to the respiratory cycle, real-time monitoring of the magnetic field was implemented, and used to correct MRI signals during post-processing. This allowed for limited improvement in MRI image quality. For further improvements, we have started a project that aims at real time field correction based on actual chest motion. For this purpose chest position is monitored during MRI acquisition, and a real-time system corrects changes in magnetic field.

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Intramural Research (Z01)
Project #
1Z01NS002990-06
Application #
7143914
Study Section
(LFMI)
Project Start
Project End
Budget Start
Budget End
Support Year
6
Fiscal Year
2005
Total Cost
Indirect Cost
City
State
Country
United States
Zip Code
van Gelderen, Peter; Jiang, Xu; Duyn, Jeff H (2017) Rapid measurement of brain macromolecular proton fraction with transient saturation transfer MRI. Magn Reson Med 77:2174-2185
Duyn, Jeff (2011) Spontaneous fMRI activity during resting wakefulness and sleep. Prog Brain Res 193:295-305
Li, Tie-Qiang; Yao, Bing; van Gelderen, Peter et al. (2009) Characterization of T(2)* heterogeneity in human brain white matter. Magn Reson Med 62:1652-7
Bianciardi, Marta; Fukunaga, Masaki; van Gelderen, Peter et al. (2009) Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study. Magn Reson Imaging 27:1019-29
Horovitz, Silvina G; Fukunaga, Masaki; de Zwart, Jacco A et al. (2008) Low frequency BOLD fluctuations during resting wakefulness and light sleep: a simultaneous EEG-fMRI study. Hum Brain Mapp 29:671-82
Silva, Afonso C; Koretsky, Alan P; Duyn, Jeff H (2007) Functional MRI impulse response for BOLD and CBV contrast in rat somatosensory cortex. Magn Reson Med 57:1110-8
Duyn, Jeff H; van Gelderen, Peter; Li, Tie-Qiang et al. (2007) High-field MRI of brain cortical substructure based on signal phase. Proc Natl Acad Sci U S A 104:11796-801
Shmueli, Karin; van Gelderen, Peter; de Zwart, Jacco A et al. (2007) Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state fMRI BOLD signal. Neuroimage 38:306-20
van Gelderen, P; de Zwart, J A; Starewicz, P et al. (2007) Real-time shimming to compensate for respiration-induced B0 fluctuations. Magn Reson Med 57:362-8
Deckers, Roel H R; van Gelderen, Peter; Ries, Mario et al. (2006) An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data. Neuroimage 33:1072-81

Showing the most recent 10 out of 34 publications