Over the past ten years, there has been a need to integrate technologies for exogenous stimulation of the brain with endogenous activation of the brain. The predominant methodologies for these are for the former transcranial magnetic stimulation and the latter functional magnetic resonance imaging. These technologies have been isolated from one another because of the high-magnetic field presented by the MRI device. Using TMS in the MRI scanner could not be done due to safety concerns as well as technical incompatibilities relating to the generation of a transient magnetic field (the method of action of TMS). However, in the past five years, MagVenture has developed an MRI compatible rTMS coil system for attachment to their excellent X100 TMS stimulator system. The X100 is capable of single pulse, paired pulse and, now under experimental testing, even repetitive TMS (rTMS). rTMS can be used by scientists and therapists to increase or decrease the excitability of cortical neurons depending on the rate of stimulation. As a result, regional activation or deactivation of the brain is altere and investigators have a short window of opportunity (effectively 10-20 minutes) to probe neuroplasticity. The X100 is capable of up to 100Hz of stimulation which is much greater than other systems on the market and gives investigators a unique capability for cortical modulation. TMS works by transiently changing the magnetic field by delivering current through a stimulating coil. MagVenture has the strongest array of stimulating coils on the market today including the only commercially available TMS coil compatible with an MRI environment. The applications of this technology are detailed in the research plans of this submission and are dependent on the needs of the individual investigators. As such, the X100 TMS-fMRI system provides a versatile tool for numerous researchers to approach questions of interest respective of their research programs. It is the only product on the market than can fulfill these needs. The current application represent interest in the use of the X100 system by 6 VA-affiliated researchers. The Major Group includes: Keith McGregor, PhD; Bruce Crosson, PhD, and Andy Butler, PhD-PT, MBA. The Minor group includes: Paul Garcia, MD., PhD; Joe Nocera, PhD, Catherin Buetefisch, MD, PhD and Michael Borich, PhD. These users represent a strong core of researchers with interests in using the X100 to improve healthcare delivery to Veteran's by improving our understanding of cortical networks.

Public Health Relevance

This submission is a request for a magnetic resonance imaging compatible transcranial magnetic stimulation (fMRI-TMS) system. The fMRI-TMS system from Magventure listed in this ShEEP proposal offers the co-authors on the submission a platform for advanced neuroimaging using external stimulation. Multiple VA projects currently funded by the Research and Development Service can make use of this equipment in a collaborative manner. This equipment has the potential to inform both basic science research and interventions that can translate into improved quality of life for Veterans. Further, it will aid the continued developmen of the co-author's research programs and will significantly improve our understanding of neural function for the aid of Veterans.

Agency
National Institute of Health (NIH)
Institute
Veterans Affairs (VA)
Type
Veterans Administration (IS1)
Project #
1IS1BX003135-01
Application #
8948786
Study Section
Special Emphasis Panel (SPLJ)
Project Start
2015-01-01
Project End
2015-09-30
Budget Start
2015-01-01
Budget End
2015-06-30
Support Year
1
Fiscal Year
2015
Total Cost
Indirect Cost
Name
Veterans Health Administration
Department
Type
DUNS #
824835805
City
Decatur
State
GA
Country
United States
Zip Code
30033
Sjuts, Hanno; Vargiu, Attilio V; Kwasny, Steven M et al. (2016) Molecular basis for inhibition of AcrB multidrug efflux pump by novel and powerful pyranopyridine derivatives. Proc Natl Acad Sci U S A 113:3509-14