This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. The subproject and investigator (PI) may have received primary funding from another NIH source, and thus could be represented in other CRISP entries. The institution listed is for the Center, which is not necessarily the institution for the investigator. In this work, the dependence of parallel MRI performance on main magnetic field strength is experimentally investigated. Using the general framework of electrodynamic scaling, the B0-dependent behavior of the relevant radiofrequency fields at a single physical field strength of 7 T is studied. In the chosen implementation this is accomplished by adjusting the permittivity and conductivity of a homogeneous spherical phantom. With different mixing ratios of decane, ethanol, purified water, N-methylformamide, and sodium chloride, field strengths in the range of 1.5 to 11.5 T are mimicked. Based on sensitivity maps of an eight-coil receiver array, the field-dependent performance of parallel imaging is assessed in terms of the geometry factor g, which reflects noise enhancement in parallel imaging reconstruction. At low field strengths the SNR penalty was nearly independent of B0 and favorably low for 1D reduction factors up to between 3 and 4. At higher field strengths the transition between favorable and prohibitive parallel imaging conditions was found to shift toward higher feasible reduction factors. These findings are in good agreement with previous theoretical predictions. From this agreement it is concluded that parallel MRI at high B0 benefits specifically from onsetting far-field behavior of the involved radiofrequency fields.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR008079-14
Application #
7358636
Study Section
Special Emphasis Panel (ZRG1-SSS-X (41))
Project Start
2006-06-01
Project End
2007-05-31
Budget Start
2006-06-01
Budget End
2007-05-31
Support Year
14
Fiscal Year
2006
Total Cost
$48,633
Indirect Cost
Name
University of Minnesota Twin Cities
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
555917996
City
Minneapolis
State
MN
Country
United States
Zip Code
55455
Herzberg, Max P; Hodel, Amanda S; Cowell, Raquel A et al. (2018) Risk taking, decision-making, and brain volume in youth adopted internationally from institutional care. Neuropsychologia 119:262-270
U?urbil, Kamil (2018) Imaging at ultrahigh magnetic fields: History, challenges, and solutions. Neuroimage 168:7-32
Foell, Jens; Palumbo, Isabella M; Yancey, James R et al. (2018) Biobehavioral threat sensitivity and amygdala volume: A twin neuroimaging study. Neuroimage 186:14-21
Magnitsky, Sergey; Pickup, Stephan; Garwood, Michael et al. (2018) Imaging of a high concentration of iron labeled cells with positive contrast in a rat knee. Magn Reson Med :
Lee, Byeong-Yeul; Zhu, Xiao-Hong; Woo, Myung Kyun et al. (2018) Interleaved 31 P MRS imaging of human frontal and occipital lobes using dual RF coils in combination with single-channel transmitter-receiver and dynamic B0 shimming. NMR Biomed 31:
Wilson, Sylia; Malone, Stephen M; Hunt, Ruskin H et al. (2018) Problematic alcohol use and hippocampal volume in a female sample: disentangling cause from consequence using a co-twin control study design. Psychol Med 48:1673-1684
Bolan, Patrick J; Kim, Eunhee; Herman, Benjamin A et al. (2017) MR spectroscopy of breast cancer for assessing early treatment response: Results from the ACRIN 6657 MRS trial. J Magn Reson Imaging 46:290-302
Nelson, Brent G; Bassett, Danielle S; Camchong, Jazmin et al. (2017) Comparison of large-scale human brain functional and anatomical networks in schizophrenia. Neuroimage Clin 15:439-448
Cusick, Sarah E; Georgieff, Michael K (2016) The Role of Nutrition in Brain Development: The Golden Opportunity of the ""First 1000 Days"". J Pediatr 175:16-21
Goerke, Ute (2016) Spatial specificity in spatiotemporal encoding and Fourier imaging. Magn Reson Imaging 34:562-73

Showing the most recent 10 out of 493 publications